PROFLO PFS5838, PFWPLUS5838, PFS6032A, PFWPLUSA6032, PFS6036N Installation Manual

...
0 (0)
READ THESE INSTRUCTIONS COMPLETELY BEFORE INSTALLING THE PRODUCT. FOR PRODUCT OR
INSTALLATION QUESTIONS PLEASE CALL CUSTOMER SERVICE AT 1-800-221-3379.
YOU MUST FOLLOW ALL INSTRUCTIONS IN THIS MANUAL: FAILURE TO DO SO WILL RESULT IN
YOUR ASSUMPTION OF LIABILITY AND WILL VOID WARRANTY AND CAN RESULT IN PRODUCT
DAMAGE OR PERSONAL INJURY.
FAILURE TO USE A SUITABLE SETTING COMPOUND WILL VOID THE WARRANTY.
THIS PRODUCT IS DESIGNED TO BE INSTALLED BY A LICENSED TRADESMAN. LICENSED
PLUMBERS AND ELECTRICIANS SHOULD BE EMPLOYED TO INSURE PROPER INSTALLATION. I
Only accessories authorized by the manufacturer should be used with this product. This product is
designed for residential use and use by healthy individuals.
IMPORTANT SAFETY INSTRUCTIONS: WARNING! WHEN USING THIS PRODUCT, BASIC PRECAUTIONS
SHOULD ALWAYS BE FOLLOWED. READ AND FOLLOW ALL INSTRUCTIONS PERTAINING TO RISK OF
FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS.
INSTALLER: LEAVE THIS MANUAL FOR HOMEOWNER.
HOMEOWNER: READ THIS MANUAL AND KEEP FOR FUTURE REFERENCE.
INSTALLATION AND OPERATING MANUAL
www.PROFLO.com
TABLE OF CONTENTS
www.PROFLO.com
Important Safety Information ....................................................................... 3-4
Recommended Tools and Material ................................................................. 4
Inspection & Testing ........................................................................................4
Electrical Requirements & Information ...........................................................5
Framing & Installation .................................................................................. 6-8
Rough-in Dimensions ................................................................................ 9-10
Care & Cleaning/Maintenance ......................................................................11
Operating Instructions ...................................................................................11
Jet Operation and Adjustment .......................................................................12
Troubleshooting .............................................................................................13
Warranty ..........................................................................................................13
IMPORTANT SAFETY INSTRUCTIONS
SAVE THIS MANUAL: RETAIN FOR CONSUMER’S USE. READ THESE INSTRUCTIONS
COMPLETELY BEFORE INSTALLING THE PRODUCT: FOR PRODUCT OR INSTALLATION
QUESTIONS PLEASE CALL CUSTOMER SERVICE AT 1-800-221-3379.
YOU MUST FOLLOW ALL INSTRUCTIONS IN THIS MANUAL: FAILURE TO DO SO WILL
RESULT IN YOUR ASSUMPTION OF LIABILITY AND WILL VOID WARRANTY AND CAN
RESULT IN PRODUCT DAMAGE OR PERSONAL INJURY. FAILURE TO USE A SUITABLE
SETTING COMPOUND WILL VOID THE WARRANTY.
THIS PRODUCT IS DESIGNED TO BE INSTALLED BY A LICENSED TRADESMAN.
LICENSED PLUMBERS AND ELECTRICIANS SHOULD BE EMPLOYED TO INSURE
PROPER INSTALLATION. INSTALLERS ASSUME ALL LIABILITY FOR THE CORRECT
INSTALLATION PROCEDURES.
Only accessories authorized by the manufacturer should be used with this product.
This product is designed for residential use and use by healthy individuals.
IMPORTANT SAFETY INSTRUCTIONS
WHEN USING THIS PRODUCT, BASIC PRECAUTIONS SHOULD ALWAYS BE
FOLLOWED. READ AND FOLLOW ALL INSTRUCTIONS PERTAINING TO RISK OF FIRE,
ELECTRIC SHOCK, OR INJURY.
IMPORTANT SAFETY INSTRUCTIONS
INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO
PERSONS READ AND FOLLOW ALL INSTRUCTIONS!
Risk of personal injury. Do not permit children to use this unit without adult supervision.
Risk of personal injury. Do not operate this unit without the guard over the suction tting.
Risk of electric shock. Do not permit electrical appliances (hair dryer, telephone, radio, etc.)
within 60 inches (1524mm) of this unit.
Risk of hypothermia and possible drowning. People using medications and/or having ad-
verse medical history should consult a physician before using this product.
Risk of personal injury. Do not overll unit before entering. Entering tub when lled more than
2/3 can cause overow and slippery conditions. Exercise caution when entering
and exiting.
No Food or Alcoholic Beverages. Use of your bathtub immediately after meals is not
recommended. Avoid alcohol consumption before or during bathing. Alcoholic beverages
can cause drowsiness or hypothermia resulting in loss of consciousness or even drowning.
Pregnancy. If you are or think you may be pregnant, consult your physician before using the
bathtub. Never drop or insert any object into any opening. Use this unit only for its intended
use as described in this manual. Do not use any attachments not recommended by
PROFLO. This equipment is intended for indoor use only.
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
www.PROFLO.com 3
www.PROFLO.com4
IMPORTANT SAFETY INSTRUCTIONS
The unit must be connected only to a supply circuit that is properly protected by a 20 amp ground-fault circuit interrupter (GFCI). Such a
GFCI should be provided by the installer and should be tested on a routine basis. To test the GFCI, push the test button. The GFCI should
interrupt power. Push the reset button. Power should be restored. If the GFCI fails to operate in this manner, the GFCI is defective. If the
GFCI interrupts power to the bathtub without the test button being pushed, a ground current is  owing, indicating the possibility of an
electric shock. Do not use this total massage, whirlpool or air bathtub. Disconnect The total massage, whirlpool or air bathtub and have the
problem corrected by a licensed electrician before using.
A pressure wire connector is provided on the exterior of the motor unit to permit connection of a no. 8 AWG solid copper bonding
conductor between this unit and all other electrical equipment and exposed metal in the vicinity, as needed to comply with local
requirements. To reduce the risk of an electric shock, connect this connector to the grounding terminal of your electric service or supply
panel with a conductor equivalent in size to the circuit conductors supplying this unit. Use supply wires that are suitable for 167°F (75°C),
including the temperature rating of the supply conductors to be used. Building materials and wiring should be routed away from the
motor/pump or blower or other heat producing components of this unit.
RECOMMENDED TOOLS AND MATERIAL
INSPECTION AND TESTING
Each bath arrives ready for installation, completely equipped with the pump and plumbing necessary for operation. However, a drain/
over ow kit is required for each bath and it is not included.
The variety of installations for this bath may require framing procedures other than those shown.
Locate studs as required. Ensure roughing-in dimensions (see pg. 11) are proper, plumb, and square.
Inspection:
Remove the bath from the carton. Retain the shipping carton until satisfactory inspection of the product has been made. Do not lift the
bath by the plumbing at any time; handle by the shell only. All bath units are factory tested for proper operation and watertight connections
prior to shipping.
Inspect the shell and bathtub components. Should inspection reveal any damage or defect in the  nish or visible damage to any
components, do not install the bathtub. Damage or defect to the  nish claimed after the bathtub is installed is excluded from the warranty.
Inspect the tub components for loose  ttings.
Testing:
Prior to installation and before enclosing with wallboard, tile, etc., the bath must be  lled with water and operated to check for leaks that
may have resulted from shipping damage or mishandling.
It is the responsibility of the installer to thoroughly test the tub prior to completing installation. Place the tub on a level surface, ensure
drain is sealed and  ll the bathtub with water to the bottom of the over ow. Allow water to sit in tub for at least 5 minutes as a static test.
If installing a system tub, plug in the motor/ pump and turn it on. Con rm all features function correctly. Visually inspect all joints for leaks.
DO NOT install tub if any leaks are detected or system functions do not work properly.
• Silicone sealant
• Tape measure
• Pencil
• Safety glasses
• Pipe wrench
• Level
Conventional woodworking
tools and materials
• Drop cloth
• 2x4’s
• Mortar
• Optional: construction adhesive
www.PROFLO.com 5
ELECTRICAL REQUIREMENTS AND INFORMATION
1. Whirlpool units require dedicated 20 Amp,120V service.
2. You must provide a receptacle with a 20-amp conguration.
3. See local codes for proper wire size. If not specied, use #12 Copper only wire.
The unit must be connected to a circuit interrupter (GFCI) provided by the installer. The (GFCI) breaker should be tested on a routine basis.
To test the (GFCI) breaker, push the test button. The GFCI should interrupt power. To restore power, push the RESET button. If the GFCI fails
to operate in this manner there is ground current owing, indicating the possibility of an electrical shock. Do not use the unit. Disconnect the
unit and have the problem corrected by a qualied service representative before using.
RISK OF ELECTRICAL SHOCK. All pumps and blowers must be connected
to a ground fault circuit interrupter (GFCI) protected outlets. Standard Line
Total Massage units can be operated on a single service. All heaters must be
connected to a ground fault circuit interrupter (GFCI) protected outlets, separate
from the pump and/or blower.
Electrical outlet must be mounted 4" (101mm) above the oor line and 12"
max (305mm) inside from the edge of the bathtub, or in accordance with local
building and electrical codes.
Risks of component over heat. Do not use electric extension cord to power
the unit. Operating the pump without enough water in bathtub can cause
permanent damage to the pump/motor.
If CFGI unit indicates a malfunction, per manufacturer’s instructions, turn OFF
power and do not attempt to use the bathtub until the source of the problem
has been identied and corrected.
WARNING
WARNING
TOTAL MASSAGE CIRCUIT WITH OPTIONAL HEATER
PUMP FLOW
CONTROLL VALVE
0.5 AMP
BACK OF 6 BTN CONTROL
PIGGY BLOWER
9.5 AMP
TMS - VARIABLE
CONTROL
TMS-P/TIMER
CONTROL
ON / OFF PUMP
9 AMP
OPTIONAL
120V, 60 HZ
20 AMP GFCI
120V / 20AMP
MALE PLUG
GFCI GFCI
ELECTRICAL
FEED
120V, 60 HZ
20 AMP GFCI
HEATER
AIR SPEED WAVE SPEEDJETS WAVE
WHIRLPOOL CIRCUIT WITH OPTIONAL HEATER
PUMP FLOW
CONTROLL VALVE
0.5 AMP
TMS-P/TIMER
CONTROL
ON / OFF PUMP
9 AMP
OPTIONAL
HEATER
120V, 60 HZ
20 AMP GFCI
120V / 20AMP
MALE PLUG
GFCI GFCI
ELECTRICAL
FEED
120V, 60 HZ
20 AMP GFCI
BACK OF 3 BUTTON CONTROL
AIR MASSAGE CIRCUIT
PIGGY BLOWER
9.25 AMP
TMS - VARIABLE
CONTROL
120V, 60 HZ
20 AMP GFCI
GFCI GFCI
ELECTRICAL
FEED
120V, 60 HZ
20 AMP GFCI
GFCI GFCI
ELECTRICAL
FEED
BACK OF 3 BUTTON CONTROL
120V, 60 HZ
20 AMP GFCI
GFCI GFCI
ELECTRICAL
FEED
120V, 60 HZ
9.25 AMP
HEATER
PIGGY BLOWER
9.5 AMP
AIR SWITCH
ON / OFF PUMP
9 AMP
AIR SWITCH
CONTROL BOX
CONTROL BOX
PIGGY BLOWER
9.5 AMP
PUMP / MOTOR
120V, 60 HZ
20 AMP GFCI
GFCI GFCI
ELECTRICAL
FEED
AIR SWITCH
AIR SWITCH
BRADENTON & PROVINCETOWN TOTAL MASSAGE
CIRCUIT WITH OPTIONAL HEATER
BRADENTON & PROVINCETOWN
AIR BATH CIRCUIT
BRADENTON & PROVINCETOWN WHIRLPOOL
WITH INSTALLED AIR SWITCH
POWER SPEED WAVE
POWER SPEED WAVE
PROFLO WHIRLPOOL
WITH INSTALLED AIR SWITCH
Loading...
+ 9 hidden pages