Prince Castle DHB2PT-32GB Installation Manual

OPERATING
INSTRUCTIONS
Dedicated Holding Bin Model No. DHB2PT-32
TABLE OF CONTENTS PAGE
Installation..................................................................... 2
Control Panel Identification . .. ...................................... 2
Programming................................................................. 2
Operation....................................................................... 3
Cleaning ........................................................................ 3
Exploded View & Parts List ........................................ 4
Troubleshooting ............................................................ 5
Wiring Diagram ............................................................. 5
LIMITED WARRANTY
This product is warranted to be free from defects in material and/or workmanship for a period of one (1) year from date of original installation (with the exception of racks, pans, and covers) not to exceed
18 months from date of shipment from our factory .
P.C. Boards and Heaters are warranted for three
(1) years from date of installation, not to exceed 18 months from date of shipment from our factory.
PRODUCT SPECIFICATION
Model No. Volts HZ Watts Amps
DHB2PT-32 208 50/60 2500 12.2
DHB2PT-32J 200 50/60 2300 11.5
DHB2PT-32CE 220-240 50 2950 12.3
DHB2PT-32GB 240 50 2950 12.3
This warranty covers on-location service (i.e., trip charges and/or mileage).
Travel mileage is limited to 100 miles (160 kilome­ters) round trip (one trip per warranty) from an authorized service agency or its sub-service agency.
Any component which proves to be faulty in material and/or workmanship will be replaced or repaired (at the option of Prince Castle, Inc.) without cost to the customer for parts or labor.
This warranty is subject to the following exceptions/ conditions:
z Any use of non-genuine Prince Castle spare
parts voids this warranty.
z All labor shall be performed by an authorized
Prince Castle Service Agent during regular work­ing hours. Overtime premium will not be covered.
z Damage caused by carelessness, neglect, and/
or abuse (e.g., dropping, tampering or altering parts), equipment damaged in shipment, by fire, flood or an act of God is not covered under this warranty.
355 East Kehoe Blvd. l Carol Stream, IL 60188
Printed in 2001
Tel: (630) 462-8800 l Fax: (630) 462-1460
Toll Free: 1-800-PCASTLE
528-501revA
INSTALLATION
1B The LED indicator next to the PROG is on
when in the Program Mode.
1. After you have removed the Bin from the carton, inspect the unit for signs of damage. If there is damage to the unit:
l Notify carrier within 24 hours after delivery. l Save carton and packing materials for inspection
purposes.
l Contact the Prince Castle Customer Sales
Department at 1-630-462-8800 to arrange for a replacement to be sent.
1. Place the bin on a counter and seal its base to
the counter with food-approved sealant.
2. Insert the power cord into a proper voltage receptacle. Note: This should be a dedicated outlet. No other equipment should be operating on this line (i.e. fryers, refrigerators, etc.)
3. Turn the power switch on. Allow 20 minutes for warm-up.
RECOMMENDED STARTING
TEMPERATURES
1. Temperature settings: There are two holding cavities, the top cavity is used to hold sides and the bottom cavity holds biscuits. There is a top heater and a bottom heater in each cavity . The temperature of each heater can be set independent of each other. The recommended starting temperature for each heater is 180°F.
1C The LED indicator next to the LWR
SHELF indicates that the temperature
being displayed is for the a heater in the lower cavity .
1D The LED indicator next to the HEAT is on
when power is applied to the heater.
1E The LED indicator next to ACTUAL
TEMP is on when the Actual Temperature
is being displayed.
1F The LED indicator next to SET POINT
TEMP is on when the Set Point Tempera-
ture is being displayed.
2. Control Panel buttons
SET POINT: The set-point temperature is displayed for the selected heaters when this button is pressed during the operat­ing mode. The SET POINT LED indicator in the display will be on when the Set­point mode is selected. Press and hold the Prince Castle button then press and hold the SET-POINT button for 5 seconds to program the temperature for the se­lected heater.
ACTUAL TEMP: The actual temperature is displayed for the selected heaters when this button is pressed during the operating mode. The ACTUAL TEMP LED indicator in the display will be on when the Set-point mode is selected.
1A
1B 1C
1E
1F
1. Display
1A The LED indicator next to the
UPR SHELF indicates that the tempera-
ture being displayed is for a heater in the upper cavity .
THE CONTROL PANEL
1D
UP ARROW and DOWN ARROW: When pressed in the operating mode, the display will scroll through the tempera tures of the heaters. The LED next to the UPR SHELF or LWR SHELF will be on to indicate which cavity is being selected. The letter U or L is displayed for the Upper or Lower heater in the selected cavity .
PROGRAMMING
The temperature adjustment range for a heater zone is: OFF, 150°F to 275°F. The recommended starting setpoint temperature for all four heaters is 180°F.
Use the following procedure to change a setpoint temperature.
2
Loading...