5.8Installing the PMI 516/PMI 518/PMI 526/PMI 531/PMI 53823
Section 6Wiring24
6.1General wiring guidelines24
6.1.1Shielding24
Operating Manual PMI 5
1002241-EN-07
3
Page 4
Contents
6.1.2Measures to protect against interference voltages24
6.2Connecting the Unit25
6.2.1Supply voltage25
6.2.2Connection example26
6.2.3Interfaces27
Section 7Putting into Service28
7.1Activating the setup28
7.2Control Panel28
7.2.1Backup and restore29
7.2.2Password settings29
Section 8Care and Maintenance32
8.1Cleaning the touchscreen32
Section 9Attachment33
9.1Supported Windows components33
9.2Windows CE Shell commands38
9.3Windows CE Shell commands - Pilz expansions40
Section 10Technical details45
Section 11Order reference49
Operating Manual PMI 5
1002241-EN-07
4
Page 5
Introduction
1Introduction
1.1Validity of the documentation
This operating manual is valid for the following products:
}PMI 509
}PMI 515
}PMI 516
}PMI 518
}PMI 526
}PMI 531
}PMI 538
This operating manual explains the function and operation, describes the installation and
provides guidelines on how to connect the product.
1.1.1Retaining the documentation
This documentation is intended for instruction and should be retained for future reference.
1.2Definition of symbols
Information that is particularly important is identified as follows:
DANGER!
This warning must be heeded! It warns of a hazardous situation that poses
an immediate threat of serious injury and death and indicates preventive
measures that can be taken.
WARNING!
This warning must be heeded! It warns of a hazardous situation that could
lead to serious injury and death and indicates preventive measures that can
be taken.
Operating Manual PMI 5
1002241-EN-07
CAUTION!
This refers to a hazard that can lead to a less serious or minor injury plus
material damage, and also provides information on preventive measures
that can be taken.
5
Page 6
Introduction
NOTICE
This describes a situation in which the product or devices could be damaged and also provides information on preventive measures that can be
taken. It also highlights areas within the text that are of particular importance.
INFORMATION
This gives advice on applications and provides information on special features.
Operating Manual PMI 5
1002241-EN-07
6
Page 7
Overview
2Overview
2.1Unit structure
The PMI is an operator terminal that is used to operate and monitor technical processes.
2.1.1Unit features
}Analogue resistive touchscreen
}Character set: Unicode
}PMI 509: in addition
–4 function keys (F1 … F4) and
–4 system keys (ESC, ENTER, cursor up, cursor down)
}Memory:
256 MB DDR SDRAM
512 MB Flash
}1 serial interface
}1 Ethernet Interface
}1 USB slave interface
}1 USB host interface (PMI 509/PMI 515)
2 USB host interfaces (PMI 516/PMI 518/PMI 526/PMI 531/PMI 538)
}Battery-buffered real-time clock
}User-specific applications and various visualisation software packages can be installed
Operating Manual PMI 5
1002241-EN-07
7
Page 8
Overview
[1]
[2]
[3]
2.2Front view
2.2.1PMI 509
Fig.: Front view PMI 509
Legende
[1] F1 ... F4 (function keys)
[2]
Touchscreen (see Technical details [ 45])
[3] ESC, ENTER, cursor up, cursor down
The key allocation is predefined by the operating system, the configuration can be changed
as desired.
Fig.: Front view of PMI 515/PMI 516/PMI 518/PMI 526/PMI 531/PMI 538
Legende
[1]
Touchscreen (see Technical Details) [ 45]
2.3Scope of supply
PMI 509
}Operator terminal
}2 retaining clamps
}Connector plug for power supply
}Projection stands
}Device documentation on CD/DVD
PMI 515
}Operator terminal
}Cover plate
}Connector plug for power supply
}Projection stands
}Device documentation on CD/DVD
Operating Manual PMI 5
1002241-EN-07
9
Page 10
Overview
PMI 516/PMI 518/PMI 526/PMI 531/ PMI 538
}Operator terminal
}Retaining clamps
}Connector plug for power supply
}Projection stands
}Device documentation on CD/DVD
Operating Manual PMI 5
1002241-EN-07
10
Page 11
Safety
3Safety
3.1Intended use
This device is used to operate and monitor technical processes.
The PMI offers the possibility of installing software from third-party suppliers. Pilz GmbH &
Co. KG accepts no liability for any damages, nor does it provide support or any guarantee
for the functional efficiency of the installed software.
INFORMATION
Ensure that the graphics software is suitable for the ARMV4i processor type
and the Windows CE 6.0 embedded operating system.
CAUTION!
The unit is not designed for use in applications with stringent safety requirements (e.g. E-STOP).
The following is deemed improper use in particular:
}Any component, technical or electrical modification to the product
}Use of the product outside the areas described in this manual
}Use of the product outside the technical details (see Technical details [ 45]).
NOTICE
EMC-compliant electrical installation
The product is designed for use in an industrial environment. The product
may cause interference if installed in other environments. If installed in other
environments, measures should be taken to comply with the applicable
standards and directives for the respective installation site with regard to interference.
Operating Manual PMI 5
1002241-EN-07
11
Page 12
Safety
3.2Safety regulations
3.2.1Use of qualified personnel
The products may only be assembled, installed, programmed, commissioned, operated,
maintained and decommissioned by competent persons.
A competent person is someone who, because of their training, experience and current professional activity, has the specialist knowledge required to test, assess and operate the
work equipment, devices, systems, plant and machinery in accordance with the general
standards and guidelines for safety technology.
It is the company’s responsibility only to employ personnel who:
}Are familiar with the basic regulations concerning health and safety / accident preven-
tion
}Have read and understood the information provided in this description under "Safety"
}And have a good knowledge of the generic and specialist standards applicable to the
specific application.
3.2.2Warranty and liability
All claims to warranty and liability will be rendered invalid if
}The product was used contrary to the purpose for which it is intended
}Damage can be attributed to not having followed the guidelines in the manual
}Operating personnel are not suitably qualified
}Any type of modification has been made (e.g. exchanging components on the PCB
boards, soldering work etc.).
3.2.3Disposal
}When decommissioning, please comply with local regulations regarding the disposal of
electronic devices (e.g. Electrical and Electronic Equipment Act).
3.3Unit-specific safety regulations
Before you install or commission the system, you should refer to any guidelines laid down
by the control manufacturer or operator.
3.3.1Installation site
}Do not position PMI close to highly flammable materials.
}When installing the unit within a control cabinet, you must ensure the ventilation slots
are not obstructed, otherwise the unit could be damaged through overheating.
}Protect the unit from direct sunlight and dust.
Operating Manual PMI 5
1002241-EN-07
12
Page 13
Safety
3.3.2Measures to protect against interference
}If necessary, use bulkhead separators to protect the unit from sources of interference.
}Inductive loads within the environment (e.g. contactor, relay and solenoid valve coils)
should be wired using suppression elements (e.g. RC elements). This is particularly important if these inductive loads are fed from the same supply.
}The power cables and the data cables should be physically separated from each other
in their own conduits (recommended minimum distance: 10 cm/3.94"). This will avoid inductive and capacitive interference.
}The prescribed earth point for the functional earth guarantees compliance with
noise immunity requirements.
Connect the functional earth to the central earth point in star form. A cable cross section of at least 1.5mm² should be used for the connection. Connections should be kept
as short as possible.
3.3.3Supply voltage
}The supply voltage must be +24VDC
CAUTION!
Safe electrical isolation must be ensured for the external power supply generating the 24V voltage supply. Failure to do so could result in electric
shock. Power supplies must conform to DINVDE0551/EN60742 and
EN50178.
3.3.4Operation
}Plan the system correctly to ensure that a communication error between the PMI and
the host computer does not cause a malfunction.
}Do not operate the touchscreen interface using hard or heavy objects or apply excess-
ive pressure.
}The maximum ambient temperature must not be exceeded when using the unit.
}Do not pour liquids over the unit or insert any objects into the unit.
}When in storage and during operation, protect the unit from vibration and shock.
}Avoid using chemicals close to the system.
3.3.5Maintenance
}Do not use thinners or organic solvents to clean the unit and touchscreen surface.
Further information on care and maintenance of the touchscreen can be found in the
chapter "Care and Maintenance".
Operating Manual PMI 5
1002241-EN-07
NOTICE
The touchscreen surface is not abrasion resistant; if it is dirty, please clean
with care and do not apply heavy pressure.
13
Page 14
Function description
[1]
[5][6][7]
[8]
[2]
[3][4]
4Function description
4.1Features
The operator terminal has a memory in which graphics display software can be installed.
With the help of this software, processes can be shown on the display and directly influenced via the touchscreen. An Ethernet interface is available for the transfer of data, e.g.
diagnostic data, and for communication with other subscribers.
The PMI 509 has additional buttons which can be used to control special functions within
an application.
The device is fitted with a real-time clock that is battery-buffered, so allowing it to run for 90
days without an external power supply. The battery is automatically charged during normal
operation by the power supply for the device.
4.2Unit views
4.2.1PMI 509
Operating Manual PMI 5
1002241-EN-07
Fig.: Top: plan view of PMI 509, Bottom: view of PMI 509 from below
Legende
[1] Serial interface COM1 (RS232)
[2] USB Slave
[3] SD/SDHC card
[4] Ethernet interface (100 BaseTX)
14
Page 15
Function description
[1]
[5][6][7]
[8]
[2]
[3][4]
[5] Supply voltage +24 VDC
[6] Audio interface LINE OUT
[7] USB Host
[8] Functional earth
4.2.2PMI 515
Fig.: Top: plan view of PMI 515, Bottom: view of PMI 515 from below
Legende
[1] Serial interface COM1 (RS232)
[2] USB Slave
[3] SD/SDHC card
[4] Ethernet interface (100 BaseTX)
[5] Supply voltage +24 VDC
[6] Audio interface LINE OUT
[7] USB Host
[8] Functional earth
Operating Manual PMI 5
1002241-EN-07
15
Page 16
Function description
[1]
[4]
[2]
[3]
[5]
[6]
[7]
[8][9]
4.2.3PMI 516/PMI 518/PMI 526/PMI 531/ PMI 538
Fig.: Top: plan view of PMI 516/PMI 518/PMI 526/PMI 531/PMI 538, Bottom: view of PMI 516/PMI
518/PMI 526/PMI 531/PMI 538 from below
Legende
[1] Audio interface LINE OUT
[2] SD/SDHC card
[3] Ethernet interface (100 BaseTX)
[4] Supply voltage +24 VDC
[5] Serial interface COM1 (RS232)
[6] USB Slave
[7] USB Host 1
[8] USB Host 2
[9] Functional earth
Operating Manual PMI 5
1002241-EN-07
16
Page 17
Installation
5Installation
5.1Safety
NOTICE
Damage due to electrostatic discharge!
Electrostatic discharge can damage components. Ensure against discharge
before touching the product, e.g. by touching an earthed, conductive surface or by wearing an earthed armband.
Please read the safety guidelines before assembling and installing the PMI.
Before you install or commission the system, you should refer to any guidelines laid down
by the plant manufacturer or operator.
5.1.1Installation site and unit surroundings
}Keep as large a distance as possible between the system and any electromagnetic
fields, particularly when frequency converters are nearby.
}To avoid the build-up of heat, a distance of 10 cm/3.94" should be kept free all round
the unit.
}Protect the system from direct sunlight and dust
}Do not use chemicals close to the system.
}Ensure the maximum ambient and operating temperatures are not exceeded.
}Ensure that neither liquids nor objects can enter the unit at any time.
}Do not position the system close to flammable materials.
When installing the unit, please note the following:
}For stability reasons, the front panel, console or control cabinet should have a wall
thickness of at least 2.5mm.
}To avoid a build-up of heat, a distance of a 10cm/3.94" should be kept free all round
the system.
}Ensure the information given for the ambient and operating temperatures in the tech-
nical details is observed.
}IP65 protection can only be guaranteed when
–the fixing screws are sufficiently tightened (min. 0.2Nm).
–the gasket is not damaged.
–the wall thickness is at least 2.5mm.
}Protect the system against falling down, i.e. ensure that the fixing screws are firmly
tightened.
5.6PMI 509 Installation
Fig.: PMI 509 Installation
Operating Manual PMI 5
1002241-EN-07
NOTICE
The torque setting for the fixing screws may not exceed 0.3 Nm.
21
Page 22
Installation
5.7PMI 515 Installation
Fig.: PMI 515 Installation
Operating Manual PMI 5
1002241-EN-07
22
Page 23
Installation
5.8Installing the PMI 516/PMI 518/PMI 526/PMI 531/PMI 538
Fig.: Installing the PMI516/PMI 518/PMI 526/PMI 531/PMI 538
Operating Manual PMI 5
1002241-EN-07
23
Page 24
Wiring
6Wiring
6.1General wiring guidelines
}Electrical or electronic components which could cause interference (contactors, thyris-
tors, relay coils and solenoid valve coils) should be physically separate from data lines.
We recommend you use a sheet metal (MU metal) bulkhead between both areas.
}Data lines and power lines should be laid separately to avoid capacitive and inductive
}Screened data lines should also be laid in a different cable duct to the main power
lines.
}Power lines should be as short as possible
}Power lines should be twisted pair cables.
}We recommend a max. length of 2 m for the USB cable, to guarantee reliable data
transfer.
}UL requirement: only use copper wiring that will withstand 60/75°C for the supply
voltage; maximum torque setting: 0.5-0.6 Nm.
6.1.1Shielding
}Connect the power cable shield with low impedance to earth.
}Use only shielded data lines.
}For high-frequency reasons, we recommend that the shielding on the data line cable
(RS 232 cable) is earthed on both sides. If you are using longer cables and there is the
possibility of transient currents, we recommend one of the following methods:
–Use equipotential bonding conductors
–Use electrical isolation
}Connect data line shields to a bus bar.
}Make the connection of the bus bar to the control cabinet/system as short and with as
low impedance as possible.
}Fasten the braided shield to the shield bar over as large a surface area as possible
(e.g. with metal hose clips or PUK cable clips).
6.1.2Measures to protect against interference voltages
}Wire-up inductive loads (e.g. contactor coils, relay coils and solenoid valve coils) using
suppression elements (e.g. RC networks). This is particularly important if these inductive loads are very close to the power supply or are fed from the same supply.
}If strong magnetic fields are present, we recommend you use a bulkhead separator, i.e.
metal sheet (MU-metal).
Operating Manual PMI 5
1002241-EN-07
24
Page 25
Wiring
1 2 3
6.2Connecting the Unit
6.2.1Supply voltage
The connection for the 24VDC supply is located on the side of the housing.
Fig.: Layout of supply voltage connector
}1: Functional earth
}2: 0 V
}3: + 24 VDC
UL requirement: Use a 24 VDC power supply (isolating source). Connect a max. 5 A fuse
between the power supply and PMI.
Operating Manual PMI 5
1002241-EN-07
25
Page 26
Wiring
[1]
[2]
[3]
[4][5]
[3]
[4]
[5]
[6]
6.2.2Connection example
Fig.: Connection example
Legende
[1] Earth star point of the unit or control cabinet
[2] Earth bus bar
[3] Supply voltage
[4] Functional earthing terminal (electronic)
[5] Functional earthing bolts (housing)
[6] Data line shield
0V and are connected internally.
Operating Manual PMI 5
1002241-EN-07
26
Page 27
Wiring
GND
n.c.
TxD
RxD
n.c.
n.c.
CTS
RTS
n.c.
n.c. = Not
connected
6.2.3Interfaces
Pin assignment of RS232 interface
(COM1)
Fig.: Pin assignment of RS232 interface, Sub-D connector, 9-pin
Operating Manual PMI 5
1002241-EN-07
27
Page 28
Putting into Service
7Putting into Service
Behaviour after switch-on
There may be a delay of several seconds between switch-on and the unit being ready for
operation.
The application software can then be installed and started.
7.1Activating the setup
If you do not press the SETUP button within 2 seconds, the "PMIStart.cmd" script file will be
run. "PMIStart.cmd" is a batch file which is processed step by step.
Fig.: Activating Setup
7.2Control Panel
All system settings can be made from the Control Panel of Windows Embedded CE 6.0.
Special features and device-specific settings are described in the following.
Operating Manual PMI 5
1002241-EN-07
28
Page 29
Putting into Service
7.2.1Backup and restore
Program which you can use to save or restore an entire directory structure.
7.2.2Password settings
Assign a password for the Control Panel to protect the settings in this area. Two levels can
be protected with different passwords.
Level 1: Master Control panel password
The whole Control Panel can be protected with a password.
Defining a password: Enter a password. Enter the password again under "Confirm password".
Change password: Same as for defining a password
Delete password: Deselect Ask for master password ….
If you select Ask for master password ..., then the system will request that the master password is entered before the Control Panel opens.
Timeout
If an incorrect password is entered three times or no valid password is entered within the
selected time, then the Control Panel is closed.
Operating Manual PMI 5
1002241-EN-07
29
Page 30
Putting into Service
Level 2: Control panel applets
Individual Control Panel "applets" can be protected with a password.
Add
Add Control Panel "applets" to the password protected area. This area is protected with a
password.
Remove
Remove Control Panel "applets" from the password protected area. This area is not protected with a password.
INFORMATION
Add Password Settings to the password protected area, otherwise the
password you enter will be unprotected and can be changed.
Operating Manual PMI 5
1002241-EN-07
30
Page 31
Putting into Service
Level 3: Network user
Access to the network servers is controlled by a central user.
To change the default settings, follow the instructions below:
User name: Enter a user name
Password: Enter a password for the network user
Confirm password: Enter the new password again
INFORMATION
The ex-works setting for the network user is:
User name: pmiuser
Password: 1234
Operating Manual PMI 5
1002241-EN-07
31
Page 32
Care and Maintenance
8Care and Maintenance
8.1Cleaning the touchscreen
Clean the unit's touchscreen at regular intervals. Use a damp cloth to do this.
NOTICE
Make sure the unit is switched off before cleaning it. This prevents you from
accidentally triggering functions when you touch the touchscreen.
Cleaning agents
Only use water and washing-up liquid to dampen the cloth. Never spray the cleaning agent
directly onto the touchscreen - spray it onto the cleaning cloth instead. Never use aggressive solvents or abrasive cleaning agents.
Operating Manual PMI 5
1002241-EN-07
32
Page 33
Attachment
9Attachment
9.1Supported Windows components
The devices work with the operating system "Microsoft Windows CE 6.0 Professional", the
following Windows components are supported:
Applications
}Active Sync (Microsoft Windows Mobile Device Center)
}CAB File Installer/Uninstaller
}WordPad
Application and Service Development
}.NET Compact Framework 3.5
}Active Template Library (ATL)
}C Libraries and Runtimes (except OEM Floating Point CRT)
- C++ Runtime Support for Exception Handling and Runtime Type Information
- Full C Runtime
- Standard IO (STDIO)
- Standard IOASCII (STDIO)
- Standard String Functions - ASCII (corestra)
}Component Services (COM and DCOM)
- DCOM
- DCOM Remoting
}Message Queuing (MSMQ)
}OBEX Client
}SOAP Client
}String Safe Utility Function
}XML - MSXML 3.0
- XML Core Services and Document Object Model (DOM)
- XML Error Strings
- XML HTTP
- XML Query Languages (XQL)
- XML Stylesheet Language Transformations (XSLT)
- XML SAX
- XML Minimal Parser
Communication Services and Networking
}Networking General
Operating Manual PMI 5
1002241-EN-07
- Extended DNS Querying and Update (DNSAPI)
- NDIS Packet Capturing DLL
- NDIS User-mode I/O Protocol Driver
- Network Driver Architecture (NDIS)
- Network Utilities (IpConfig, Ping, Route)
33
Page 34
Attachment
- TCP/IP
- It includes support for IP, ARP, ICMP, IGMP, TCP, UDP, name resolution and registration, DHCP.
- Windows Networking API/Redirector (SMB/CIFS)
- Winsock Support
}Networking - Local Area Networking (LAN)
- Wired LAN (802.3, 802.5)
}Networking - Wide Area Networking (WAN)
- Dial Up Networking (RAS/PPP)
- Telephony API (TAPI 2.0)
}Servers
- Core Server Support
- File Server
- File Server (SMB/CIFS)
- FTP Server
- Simple Network Time Protocol (SNTP)
- SNTP Client with DST
- SNTP Server
- Telnet Server
- Web Server (HTTPD)
- Active Server Pages (ASP) Support
- JScript 5.6
- VBScript 5.6
- Web Server Administration ISAPI
- WEBDAV Support
Core OS Services
}System Event Log
}Battery Driver
- Debugging Tools
- Toolhelp API
}Device Manager
}Display Support
}Kernel Functionality
- Fiber API
- Format Message API
- Format Message API - System Error Messages
- Memory Mapped Files
- Message Queue - Point-to-Point
- Target Control Support (Shell.exe)
}UI based Notification
}Notification LED Support
}Power Management (Full)
}Serial Port Support
}UI Proxy for Kernerl-Mode-Drivers
Operating Manual PMI 5
1002241-EN-07
34
Page 35
Attachment
}USB Host Support
- USB Function Driver
- USB Host Driver
- USB Human Input Device (HID) Class Driver
- USB Printer Class Driver
- USB Storage Class Driver
}Windows Embedded CE Driver Development Kit Support Library
File System and Data Store
}Compression
}Database Support (CEDB Database Engine)
- CEDB Database Engine
}File and Database Replication (Bit-based)
}File System - Internal (RAM and ROM File System)
}Registry Storage (Hive-based Registry)
}Storage Manager
- CD/UDFS File System
- exFAT File System
- FAT File System
- Partition Driver
- Release Directory File System
- Storage Manager Control Panel Applet
- Transaction-Safe FAT File System (TFAT)
}System Passwort
Fonts
The following fonts have been preinstalled:
}Arial
}Comic Sans MS
}Courier New
}Georgia
}Impact
}Kino
}MSLogo
}Symbol
}Tahoma
}Times New Roman
}Trebuchet MS
}Verdana
}Webdings
}Webding
}Wingding
Operating Manual PMI 5
1002241-EN-07
35
Page 36
Attachment
INFORMATION
TTF formats can be post-installed.
– Option 1:
Use the Windows CE Shell command "fontreg" (see Windows CE
Shell command- Pilz extensions)
Syntax: fontreg.exe FONTNAME [/h] [/H] [/?] [/help]
– Option 2:
Create a new "Fonts" folder under "Flash/Windows" and save all TTF
fonts under "Flash/Windows/Fonts". Please note that after each reboot the complete content of "Flash/Windows" is copied to the "Windows " folder of the RAM.
Graphics and multimedia formats
}Audio (Waveform Audio)
}Graphics
- Alphablend API (GDI version)
- DirectDraw
- Gradient Fill Support
- Imaging
- Still Imagine Codec Support (Encode and Decode)
- Still Image Decoders
- BMP
- GIF
- ICO
- JPG
- PNG
- TIFF
- Still Image Encoders
- BMP
- GIF
- JPG
- PNG
- TIFF
International
}Input Method Manager (IMM)
}Locale Service (National Language Support (NLS))
}Locale Specific Support (English US - US Keyboard)
Operating Manual PMI 5
1002241-EN-07
36
Page 37
Attachment
Internet Client Services
}Browser Application
- Internet Explorer 6.0 for Windows Embedded CE - Standard Components
- Internet Explorer 6.0 Sample Browser
}Internet Explorer 6.0 for Windows Embedded CE Components
- Internet Explorer Browser Control Host
- Internet Explorer HTML/DHTML API
- Internet Explorer Plug-in Image Decoder API
- Internet Explorer PNG Image Decoder
- MSHTML Data Binding
- Internet Explorer Multi-Language Base API
- URL Moniker Service
- Windows Internet Services
- XML Data Islands
- XML MIME Viewer
- Internet Option Control Panel
- Scripting
- JScript 5.6
- Script Authoring (Jscript)
- Script Encode (Jscript)
- VBScript 5.6
- MsgBox and InputBox support
- Script Authoring
- Script Encode (VBScript)
Security
}Authentication Services (SSPI)
- NTLM
- Schannel (SSL/TLS)
}Credential Manager
}Cryptography Service (CryptoAPI 1.0) with High Encryption Provider
- Certificates (CryptoAPI 2.0)
Shell and User Interface
}Graphics, Windowing and Events
- Minimal GDI Configuration
- Minimal GWES Configuration
- Minimal Input Configuration
- Minimal Window Manager Configuration
}Shell
- AYGShell API Set
- Command Shell
- Command Processor
- Console Window
- Graphical Shell - Standard Shell
Operating Manual PMI 5
1002241-EN-07
37
Page 38
Attachment
}User Interface
- Common Controls
- Common Control
- Common Dialog Support
- Control Panel Applets
- Customizeable UI
- Windows XP-like Sample Skin
- Gesture
- Gesture Animation Support
- Gesture Support for Win32 Controls
- Single-Touch Gesture Recognition
- Mouse
- Network User Interface
- Software Input Panel
- Software-based Input Panel (SIP)
- SIP for Large Screens
- SIP for Small Screens
- Software-based Input Panel Drivers
- Touch Screen (Stylus)
Windows Embedded CE Error Reporting
}Error Report Generator
}Error Report Transfer Driver
9.2Windows CE Shell commands
Commands Shell parameters
CommandDescription
"/C"Execute command and exit "Command processor shell".
"/K"Execute command, "Command processor shell" remains active
"string"Command that is to be executed
Syntax of the command line
CommandDescription
"COMMAND"Command name
"OPTIONS"Command specification
">"Forward the output text to a file
Operating Manual PMI 5
1002241-EN-07
"2>"Forward the output fault to a file
">>"Attach the output text to a file
"2>>"Attach the output fault to a file
"<"reads input text from a file
"&"separates a command or several commands
38
Page 39
Attachment
CommandDescription
"|"separates a command or several commands and sends the output of
a command as input for the command that follows
"file1"Name of the file that includes the output
"file2"Name of the file that includes the input
List of all possible Shell commands
CommandDescription
"ATTRIB"shows or changes the properties of a file
"CALL"calls up a batch program from another batch program
"CHDIR, CD"shows the name of the current directory or changes the current direct-
ory
"CLS"deletes the screen
"COPY"copies one or several files to a different directory
"DATE"shows or sets the date
"DIR"shows the files and subdirectories that a directory includes
"ECHO [mes-
shows a message or activates/deactivates the echo
sage] [on| off] "
"ERASE, DEL"deletes a file or several files
"EXIT"exits "command processor shell"
"GOTO"causes the "command processor" to jump into a highlighted line in a
batch program
"HELP"shows a list of available commands
"IF"executes conditional processing in a batch program
"MKDIR, MD"creates a directory
"MOVE"moves files from one directory to another
"net"executes network-related operations
"PATH"shows or sets a search path for executable files
"PAUSE"interrupts the processing of a batch program
"PROMPT"changes the prompt for the "command processor"
"PWD"prints the current directory path
"REM"saves comments to a batch file
Operating Manual PMI 5
1002241-EN-07
"RENAME, REN" changes the name of one or several files
"RMDIR, RD"deletes a directory
"SET"sets or removes an environment variable or shows the values of all
environment variables
"SHIFT"changes the position of variable parameters in a batch file
"START"starts a separate window that executes a certain application or com-
mand
"TIME"shows the system time or sets it
39
Page 40
Attachment
CommandDescription
"TITLE"sets the title of the "command processor" window
"TYPE"shows the content of a text file or several text files
9.3Windows CE Shell commands - Pilz expansions
INFORMATION
You can use the command "/?" to call up the help. There you find more information on the individual commands.
Common parameters
CommandDescription
"/h"shows the help
"/H"shows the help
"/?"shows the help
"/help"shows the help
fontregCommand for registering additional TTF fonts on the device
Syntax: fontreg FONTNAME
ParameterDescription
FONTNAMEcan include placeholders, e.g. \*.ttf; when "FONT-
NAME" is a directory, all the fonts are registered in
the directory.
formatCommand for formatting a removable data medium for use with Win-
dows CE
Syntax: format <volume> [/Q] [/A size] [/FS <File system>]
ParameterDescription
/FSdetermines the file system (FAT12, FAT16, FAT32,
or exFAT)
/Qperforms quick formatting
/LLFperforms formatting with a low formatting rate
/PARTcreates a standard partition after formatting with a
low formatting rate
/Aoverwrites the standard sizes of memory allocation
/Tcreates a TFAT format
/YConfirmation
Operating Manual PMI 5
1002241-EN-07
40
Page 41
Attachment
hostetcAdministration of host name assignment to the IP address
Syntax: hostetc [/add] [/ipv4 <ip string> ] <hostname>
ParameterDescription
/addadds a new host
/deletedeletes a host
/listshows all hosts
/acreates an Alias name (e. g. -a alias1,alias2)
/ipv4IP-String v4
/ipv6IP-String v6
/tPeriod of validity (example:
\"1985-04-12T23:20:50.52Z\", rfc 3339)
killCommand used to force the completion of a process
Syntax: kill [EXENAME] /[PID]
ParameterDescription
EXENAMEcompletes the process via the process name (e.g.
kill pnotepad.exe)
/PIDcompletes the process via the PID hexadecimal
format (e.g. kill /fa00ce)
pnotepadCommand use to start a simple text editor
Syntax: pnotepad file
ParameterDescription
fileafter starting the text editor a file is opened
psshows all the active processes
Syntax: ps
rebootCommand used to restarting the unit
Syntax: reboot <sec>
ParameterDescription
<sec>Waiting period in seconds before the device is re-
started.
regeditCommand used to start the registration editor
Syntax: regedit
regeraseCommand used to delete the present registration of the device; in the
next boot process the device uses the default registration
Syntax: regerase [-r]
ParameterDescription
-rforces a reboot process
Operating Manual PMI 5
1002241-EN-07
41
Page 42
Attachment
regexpCommend used to export a registration key including subkeys to a file
ParameterDescription
/r <BaseKey>Registration key that is to be exported
/f <OutFile>Name of the target file
/cconverts REG_MUI_SZ to REG_SZ
/ALLParameter used to export the whole registration to
a file (*.reg)
regimpCommand used to import a registration file (*.reg)
Syntax: regimp <InFile> [/temp] [/info]
ParameterDescription
<InFile>File name
/temptemporarily saved, the present registration is not
overwritten
/infoStatus information on the success/failure of the ac-
tion
regsaveCommand used to permanently save the current registration
Syntax: regsave
regsvrceCommand used to register ActiveX module (*.ocx, *.dll)
Syntax: RegsvrCE [/u] [/n] [/s] [/i[:cmdline]] dllname
ParameterDescription
/uDeregisters the server
/n"DllRegisterServer" is not called up, the parameter
must be used with "/i"
/ssuppresses messages on the display
/i <cmdline>transmits an optional command line (cmdline) to
DllInstall; when "/i" is combined with "/u", DllUnin-
stall is executed
dllnameDLL name
screenshotCommand used to print a screenshot or to save a file
Syntax: ver [/d] [/a] [/hw /p /o /l /s /r /c]
ParameterDescription
/dData mode, display without description, e.g.:
..
PMI 515
10000007
264515
..
/ashow all information
/hwoutputs the hardware version
/poutputs the processor type
/ooutputs the build version of the operating system
/loutputs the bootloader version
/toutputs the device type
/soutputs the serial number
/routputs the order number
/coutputs the chip set version
Operating Manual PMI 5
1002241-EN-07
43
Page 44
Attachment
xcopyCommand used to copy files and directory structures
In accordance with the
standardEN 60068-2-27EN 60068-2-27EN 60068-2-27
Acceleration15g15g15g
Duration11 ms11 ms11 ms
Protection type
In accordance with the
standardEN 60529EN 60529EN 60529
HousingIP65IP65IP65
In accordance with UL 1,2,5,4/4X indoor use
only
1,2,5,4/4X indoor use
only
1,2,5,4/4X indoor use
only
Mechanical data264526264531264538
Dimensions
Height243 mm276 mm332 mm
Width317 mm352 mm412 mm
Depth62,5 mm63,3 mm63,3 mm
Weight2.227 g2.860 g4.166 g
Where standards are undated, the 2010-12 latest editions shall apply.
Operating Manual PMI 5
1002241-EN-07
48
Page 49
Order reference
11Order reference
Product typeFeaturesOrder No.
PMI 509Operator terminal, 320 x 240 pixel resolution,
analogue resistive touchscreen, 4 function keys
PMI 515Operator terminal, 320 x 240 pixel resolution,
analogue resistive touchscreen
PMI 516Operator terminal, 640 x 480 pixel resolution,
analogue resistive touchscreen
PMI 518Operator terminal, 800 x 480 pixel resolution,
analogue resistive touchscreen
PMI 526Operator terminal, 800 x 600 pixel resolution,
analogue resistive touchscreen
PMI 531Operator terminal, 800 x 600 pixel resolution,
analogue resistive touchscreen
PMI 538Operator terminal, 1024 x 768 pixel resolution,
analogue resistive touchscreen
264 509
264 515
264 516
264 518
264 526
264 531
264 538
Operating Manual PMI 5
1002241-EN-07
49
Page 50
The Best of
German
En
gineering
Partner of:
Support
Technical support is available from Pilz round the clock.
Americas
Brazil
+55 11 97569-2804
Canada
+1 888-315-PILZ (315-7459)
Mexico
+52 55 5572 1300
USA (toll-free)
+1 877-PILZUSA (745-9872)
Asia
China
+86 21 60880878-216
Japan
+81 45 471-2281
South Korea
+82 31 450 0680
Australia
+61 3 95446300
Europe
Austria
+43 1 7986263-0
Belgium, Luxembourg
+32 9 3217575
France
+33 3 88104000
Germany
+49 711 3409-444
Ireland
+353 21 4804983
Italy
+39 0362 1826711
Scandinavia
+45 74436332
Spain
+34 938497433
Switzerland
+41 62 88979-30
The Netherlands
+31 347 320477
Turkey
+90 216 5775552
United Kingdom
+44 1536 462203
You can reach our
international hotline on:
+49 711 3409-444
support@pilz.com
CMSE
®
, InduraNET p
®
, PAS4000
®
, PAScal
®
, PASconfig
®
, Pilz
®
, PIT
®
, PLID
®
, PMCprimo
®
, PMCprotego
®
, PMCtendo
®
, PMD
®
, PMI
®
, PNOZ
®
, Primo
®
, PSEN
®
, PSS
®
, PVIS
®
, SafetyBUS p
®
,
SafetyEYE
®
, SafetyNET p
®
, THE SPIRIT OF SAFETY
®
are registered and protected trademarks of Pilz GmbH & Co. KG in some countries. We would point out that product features may vary
from the details stated in this document, depending on the status at the time of publication and the scope of the equipment. We accept no responsibility for the validity, accuracy
and entirety of the text and graphics presented in this information. Please contact our Technical Support if you have any questions.
Pilz develops environmentally-friendly products using
ecological materials and energy-saving technologies.
Oces and production facilities are ecologically designed,
environmentally-aware and energy-saving. So Pilz oers
sustainability, plus the security of using energy-ecient