PEERLESS Partner PP-120, Partner PP-80, Partner PP-40, Partner PP-60 Installation, Operation & Maintenance Manual

Partner ®
Water Heater
RTNER _!
Installation,
Operation Et
Maintenance Manual
PARTNER °
IN_l_t FI_D WATER HEATE_
4 Sizes 37 to iig Gallon Capacity
295 to 513 GPH First Hour Rating
Uses the Existing Boiler as its Heat Source
No Separate Chimney or Burner Required
Functions as an Additional Heating Zone
Long Lasting Stainless Steel Construction
High Grade 316L Stainless Steel Tank
Superior Corrosion Resistance
Drain Tapping for Draining and Flashing Tank
Cupronickel Fin-Tube Heat Exchanger
Provides Maximum Heat Transfer for Rapid Recovery Rates
Resists Mineral Buildup and Sealing Deposits
1" Boiler Connections Provide for Minimum Pressure Drop thru Heat Exchanger
Minimal Standby Temperature Loss
2" Polyurethane Foam Insulation
Less Than 1/2 ° Fper Hour Standby Loss
Minimal Boiler F#ing to Maintain Temperature
Provides More Hot Water with Reduced Boiler Water Temperatures
Maintenance-Free Plastic Jacket
Will Not Scratch or Rust
Color Coordinated to Match Peerless Boiler Jackets
Enclosed Thermostat Well
Control Can Be changed Without Draining Tank
Honeywell Well Type Adjustable Control
T & P Relief Valve
Cupronickel Fin & Tube Heat Exchanger
High Grade 316L Stainless Steel Tank
Plastic Jackel with 2" Polyurethane Foom
Insulation
one-year tvatTanty.tot tilt, P(,(,Hes.,; Pcwlnet" lndirz_cI Fir_'d Water 1tearer: Peerless also ptz)vicles a
limited, l!]_linle tL,arr_ltlty agamsl leaks.t}om th(_ h('aa'rsjctch_'t, latllc, of h('(tl t'xchculgcr [(_F r('._icl_'tJliol applicatiotts aiid o limit ('d..]lv(_-y_,c2r tt,6ltTOlll_] ttgoitl_l I(?c_ks./}om I]lc h(!(llt'l'N,/(l(']t-_'l I(tt!]¢ or ]|C(JI t_VCh(Itl(]('!'.t()l ('Ol!ltlR'tY'i(ll tlpl)licoliotl._. [Jl('(t._(" Cotl.';ttlt P¢'crlt's_; Boilers.l_r complett" [L'OIT(II1QI iq/ormation.
Peerless Boilers * 610-367-2153 * www.peerless heater.com
FAB PARTNER R2 (303 IM)
Prlrll_?cI it1 L} _ A
PEERLESS
PARTN E R °
INDIRECT-FIRED WATER HEATER
PARTNER ®
Modern Coil Design
u Minimal Standby Temperature
Loss
u Rapid Recovery Rate
Long Lasting Stainless Steel Construction
Q Easy Installation Q No Separate Chimney or Burner
Needed
The Peerless Partner _ indirect-fired water heater provides a true
advancement in hot water generation. By utilizing the existing boiler as its heat source, the burner fires only when necessary and
transfers heat energy through a highly efficient cupronickel, fin-tube heat exchanger. The heater functions as a separate heating zone
and water movement is regulated from the boiler through the heater coil by a separate circulator or zone valve.
The modem coil design of the Peerless Partner indirect-fired
water heater provides maximum heat transfer efficiency and resists mineral buildup that discolors water. Old style coils can produce
discolored tapwater that affects taste and leaves blue bathtub rings.
The heater's cupronickel heat exchanger is highly resistant to any
scaling deposits and is positioned so entering water provides scrubbing action, eliminating the need for chemical cleanings.
The domestic hot water is stored in a high-grade 316L stainless
steel tank. Two inch foam insulation keeps the water hot with a standby loss of less than 1/2° F per hour. This allows the boiler to
stay off most of the day and night. The result is more hot water with reduced boiler water temperatures and drastically reduced
standby losses.
The Peerless Partner indirect-fired water heater has two or more
times the recovery rate of gas-fired water heaters and supplies as much as five times the amount of hot water as a comparably sized
electric water heater.
This heater is an ideal replacement for existing water heaters. It can
also be used for new applications. A vent or stack is not required. The tank's light weight makes it very easy to position. The plastic jacketing is
maintenance free and does not scratch or rust.
The Peerless Partner indirect-fired water heater comes equipped with an adjustable, well-type Honeywell control and a T&P relief valve as standard equipment.
Model Storage
Number Capacity
PP-40 37 gallons PP-6O 57 gallons PP-80 77 gallons
PP-120 119 gallons
Heat
Pressure Exchange First Hour Ratings*
Test Working Su #ace @140 ° @115 °
300 PSI 150 PSI 15 sq ft. 200 gallons 295 gallons 300 PSI 150 PSI 15 sq ft 255 gallons 347 gallons 300 PSI 150 PSI 34 sq ft 300 gallons 400 gallons
300 PSI 150 PSI 34 sq. ft. 385 gallons 513 gallons
* Based on 90" F rise. 55_/145 _ with 180 ° F boiler water First hour rating is only one factor in product selection Refer to Installation
h_structions for additional information
)EERLESS PARTNER®SPECS
Floor To
= High-Grade 316L Stainless Steel Tank Model Boiler Boiler Domestic
Number Height Diameter Supply Return In/Out
Maintenance-Free Plastic Jacket PP-40 521/2" 19v4" 9" 4w' 3" 46" PP-6O 52V2" 23V4" 9" 41/2" 3" 46"
= 2" Polyurethane Foam Insulation PP-80 72" 24" 29" 6 6" 66"
Cupronickel, Fin-Tube Coil Assembly ___
Enclosed Thermostat Well
Adjustable Honeywell Control
T&P Relief Valve
Domestic
Water
Connections
¾" N.P.T. Male
1" N.P.T. Male 1V2"N.P.T. Male 1_/2"N.P.T. Male
Approx.
Shipping
Model Weight
Number Length Width Height (Ibs.)
PP-40 2OW' 20V2" 56" 78 PP*6O 24V2" 24V2" 56" 98
PP-80 25V2" 251/2" 74" 139
PP-120 29" 29" 78" 206
Hot Water Outlet,
T&P Relief Valve
Domestic Water
Connections (See
Dimensional Data)
Cold Water
Inlet & Drain
FLOOR
2" Polyurethane Foam
-- Insulation On Outside, Less Than 1/2 ° F Per
Hour Heat Loss R17
-- 316L Stainless Steel Tank
-- Plastic Jacket
Enclosed Thermostat Weft for
Adjustable Honeywell Control
(Boiler Water Supply & Return 1" Threaded)
Boiler Supply Cupronickel
Coil Assembly Boiler Return
The residential warranty covers:
--the entire water heater, one year from date of installation.
---outside jacket, inner tank, or heat exchanger, lifetime.
The commercial warranty covers:
--the entire water heater, one year from date of installation.
--outside jacket, inner tank, or heat exchanger, second through fifth year.
*Before purchase contact your installing contractor for complete warranty
information.
PEERLESSHEATER CO.
231 North Walnut Street
Boyer_own, PA 19512-1021
Phone: 610-367-2153 FAX: 610-369-3284
www.peerless-heater.com
CUT pARTNER £2 ( 11/02 10M} Pr_nt_ d _n U S A _'y2002 Peerless Heater Cot_tpany
1. The following guidelines apply to residential systems only. For commercial or institutional installations contact your local Peerless Heater Company representative.
2. Determine the quantity of domestic hot water required. Factors to consider: a. Estimate typical peak hour demand. Determine the general time of day (morning, noon, evening) when the
most hot water is used. Use chart below to determine potential maximum usage.
Estimate of Peak Domestic Hot Water Usage
AverageGallons of Times Used During Gallons Used in
Use Hot Water perUsage One Hour One Hour Shower 20 x -
Bath 20 x = Shaving 2 x =
Hands and Face Washing 4 x = Hair Shampoo 4 x = Hand Dish Washing 4 x = Automatic Dish Washing 14 x = Food Preparation 5 x = Wringer Clothes Washer 26 x =
Automatic Clothes Washer 32 x =
Total Peak Hour Demand =
b. Estimate unusual peak draw demand. Whirlpool baths, hot tubs, and multiple head showers require
large quantities of hot water in a short period of time. Contact fixture manufacturer for quantity of water required. Generally speaking, these circumstances can only be met with larger storage volumes.
c. Domestic Water Temperature. Most residential usage will be satisfied with 119°F water, the temperature
setting recommended by the Consumer Product Safety Commission. Some applications such as laundry and dishwashers may require a higher temperature.
Ratings can be improved by increasing Peerless ®Partner ®thermostat setting and using a mixing valve to
temper the hot water to the proper temperature. When temperatures greater than 119°F are required, use
a mixing valve at the outlet of the water heater or anti-scald fittings at point of use.
Water temperatures over 125°F can cause severe burns instantly, or death from scalds.
Children, disabled, and elderly are at the highest risk of being scalded. See instruction manual before setting temperature at water heater. Feel water before bathing or showering. Temperature limiting valves are available, see manual.
The Peerless Partner indirect-fired water heater is deemed to be used in a "commercial setting" if at any time the unit is operated at a temperature over 150°F. Refer to warranty for additional information.
Loading...
+ 10 hidden pages