Installation and Assembly:
Articulating Wall Mount for 22" - 40" (56 - 102 cm) Flat Panel Displays
Models: PA740, PA740-S
Features:
•Fits 22" - 40" (56 - 102 cm) fl at panel displays
•Two tensionable pivot points for extensive adjustment of viewing angle
•VESA® 75/100/200 x 100/200 x 200 compatible
•Frees up space by folding fl at against the wall
|
|
|
|
I |
762 |
||
D |
|||
: |
|||
000 |
0018 |
|
Max UL Load Capacity:
80 lb (36 kg)
2300 White Oak Circle • Aurora, Il 60502 • (800) 865-2112 • Fax: (800) 359-6500 • www.peerlessmounts.com
ISSUED: 01-27-08 SHEET #: 095-9283-8 01-25-12
NOTE: Read entire instruction sheet before you start installation and assembly.
WARNING
•Do not begin to install your Peerless product until you have read and understood the instructions and warnings contained in this Installation Sheet. If you have any questions regarding any of the instructions or warnings, for US customers please call Peerless customer care at 1-800-865-2112, for all international customers, please contact your local distributor.
•This product should only be installed by someone of good mechanical aptitude, has experience with basic building construction, and fully understands these instructions.
•Make sure that the supporting surface will safely support the combined load of the equipment and all attached hardware and components.
•Never exceed the Maximum UL Load Capacity. See page one.
•If mounting to wood wall studs, make sure that mounting screws are anchored into the center of the studs. Use of an "edge to edge" stud fi nder is highly recommended.
•Always use an assistant or mechanical lifting equipment to safely lift and position equipment.
•Tighten screws fi rmly, but do not overtighten. Overtightening can damage the items, greatly reducing their holding power.
•This product is intended for indoor use only. Use of this product outdoors could lead to product failure and personal injury.
•This product was designed to be installed on the following wall construction only;
WALL CONSTRUCTION |
HARDWARE REQUIRED |
|
• |
Wood Stud |
Included |
• |
Wood Beam |
Included |
• |
Solid Concrete |
Included |
• |
Cinder Block |
Included |
• |
Metal Stud |
Do not attach except with Peerless Metal Stud Accessory Kit |
|
|
(not evaluated by UL) |
• |
Brick |
Contact Qualifi ed Professional (not evaluated by UL) |
• |
Other or unsure? |
Contact Qualifi ed Professional |
Tools Needed for Assembly
• |
stud fi nder ("edge to edge" stud fi nder is recommended) |
|
• |
phillips screwdriver |
|
• |
drill |
|
• |
5/16" (8 mm) bit for concrete and cinder block wall |
|
• |
5/32" (4 mm) bit for wood stud wall |
|
• |
level |
|
Table of Contents |
|
|
Parts List................................................................................................................................................................................. |
3 |
|
Installation to Wood Stud Wall................................................................................................................................................ |
5 |
|
Installation to Solid Concrete and Cinder Block ..................................................................................................................... |
6 |
|
Attaching Adapter Plate to Display with VESA® Mounting Pattern ......................................................................................... |
7 |
|
Installing to Peerless PLP Model Adapter Bracket ................................................................................................................. |
8 |
|
Cord Management................................................................................................................................................................ |
10 |
2 of 46 |
ISSUED: 01-27-08 SHEET #: 095-9283-8 01-25-12 |
Before you begin, make sure all parts shown are included with your product.
Parts List
|
|
|
|
PA740 |
PA740-S |
|
|
Description |
Qty. |
Part # |
Part # |
|
A wall mount assembly |
1 |
095-P1704 |
095-4704 |
|
|
B concrete anchor |
2 |
590-0320 |
590-0320 |
|
|
C #14 x 2-1/2" flat head wood screw |
2 |
520-1202 |
520-2165 |
|
|
D 1/4-20 x .5" knob |
1 |
560-1162 |
560-1162 |
|
|
E |
M4 x 10 mm phillips screw |
4 |
504-9012 |
520-2027 |
|
F |
M6 x 12 mm phillips screw |
4 |
520-1128 |
520-2039 |
|
G |
M6 x 20 mm phillips screw |
4 |
520-9402 |
520-2040 |
|
H |
M8 x 10 mm phillips screw |
4 |
520-1605 |
520-2605 |
|
I |
M5 x 6 mm phillips screw |
4 |
520-1023 |
520-2214 |
|
J |
#10 flat washer |
4 |
540-9400 |
540-9442 |
|
K |
hook plate |
1 |
095-P1561 |
095-4561 |
|
L |
adapter plate |
1 |
095-P1721 |
095-4721 |
|
M cable tie |
3 |
560-9711 |
560-2004 |
|
|
N cable tie anchor |
3 |
590-1290 |
590-1290 |
|
|
O |
8-32 x 1/4" flat head screw |
3 |
520-1622 |
520-2622 |
|
P |
spacer |
4 |
590-5005 |
590-5003 |
Parts may appear slightly different than illustrated.
A |
B |
D |
|
||
|
|
|
|
C |
|
|
|
K |
E F G H I J
L
M N
O
P
3 of 46 |
ISSUED: 01-27-08 SHEET #: 095-9283-8 01-25-12 |
1 Loosen 1/4-20 x 1/2" screws to remove hook bracket (K) from wall mount assembly prior to installation.
A
K
1/4-20 X 1/2" SCREWS
4 of 46 |
ISSUED: 01-27-08 SHEET #: 095-9283-8 01-25-12 |
Installation to Wood Stud Wall
WARNING
•Installer must verify that the supporting surface will safely support the combined load of the equipment and all attached hardware and components.
•Tighten wood screws so that wall plate is fi rmly attached, but do not overtighten. Overtightening can damage the screws, greatly reducing their holding power.
•Never tighten in excess of 80 in. • lb (9 N.M.).
•Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to edge" stud fi nder is highly recommended.
•Hardware provided is for attachment of mount through standard thickness drywall or plaster into wood studs. Installers are responsible to provide hardware for other types of mounting situations (not evaluated by UL).
Using a stud fi nder, locate and mark the edges of the wood stud used in mounting this product. Use of an edge to 2 edge stud fi nder is highly recommended. Use a level to draw a vertical line down the center of the stud. Use wall
plate as template to mark center of holes along the vertical line. Drill two 5/32" (4 mm) dia. holes 2.5" (64 mm) deep. Attach wall mount (A) to wall using two #14 x 2.5" fl at head wood screws (C) as shown.
Skip to step 3.
WOOD
STUD
WALL PLATE
C
A
5 of 46 |
ISSUED: 01-27-08 SHEET #: 095-9283-8 01-25-12 |
Installation to Solid Concrete and Cinder Block
WARNING
•When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" (35 mm) of actual concrete thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a solid part of the block, generally 1" (25 mm) minimum from the side of the block. Cinder block must meet ASTM C-90 specifi cations. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to avoid breaking out the back of the hole when entering a void or cavity.
•Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
•Make sure that the wall will safely support four times the combined load of the equipment and all attached hardware and components.
Level and use wall plate as template to mark center 2 of holes. Drill two 5/16" (8 mm) dia. holes to a
minimum depth of 2.5" (64 mm). Insert anchors (B) in holes fl ush with wall. Place wall mount (A) over anchors and secure with wood screws (C). Make sure wall mount is level, and tighten all fasteners.
WARNING
•Tighten screws so that wall plate is fi rmly attached, but do not overtighten. Overtightening can damage screws, greatly reducing their holding power.
•Never tighten in excess of 80 in. • lb (9 N.M.).
•Always attach concrete expansion anchors directly to load-bearing concrete.
•Never attach concrete expansion anchors to concrete covered with plaster, drywall, or other
fi nishing material. If mounting to concrete surfaces covered with a fi nishing surface is unavoidable (not evaluated by UL), the fi nishing surface must be counterbored as shown below. Be sure concrete anchors do not pull away from concrete when tightening screws. If plaster/drywall is thicker than 5/8" (16 mm), custom fasteners must be supplied by installer (not evaluated by UL).
|
INCORRECT |
CORRECT |
|
VIEW |
concrete |
wall |
concrete |
wall |
plate |
|
|
plate |
|
||
|
|
||
CUTAWAY |
plaster/ |
|
plaster/ |
drywall |
|
drywall |
|
|
|
|
1 |
concrete |
surface |
B
Drill holes and insert anchors (B).
2 |
A |
|
|
C |
B |
Place plate (A) over anchors (B) and secure with screws (C).
3
Tighten all fasteners. |
SOLID CONCRETE |
CINDER BLOCK |
B
WALL PLATE
A
C
6 of 46 |
ISSUED: 01-27-08 SHEET #: 095-9283-8 01-25-12 |
Attaching Adapter Plate to Display with VESA 200 or 200 x 100 Mounting Pattern
NOTE: For VESA 75 mm and 100 mm patterns, see |
4 |
FOR VESA 200 x 100 MOUNTING PATTERN: |
|
following page. |
Choose hole pattern as shown below. Attach |
||
3 |
Attach hook bracket (K) onto adapter plate (L) using |
|
adapter plate (L) to back of display using four |
four M5 x 6 mm screws (I) and #10 washers (J) as |
|
M4 screws (E) as shown below. |
shown.
L
L
K
J
I
E
WARNING
FOR VESA 200 MOUNTING PATTERN USING M4 SCREWS:
Attach adapter plate (L) to back of display with four M4 screws (E) using hole pattern shown below.
•If screws don't get three complete turns in the display inserts or if screws bottom out and bracket is still not tightly secured, damage may occur to display or product may fail.
FOR VESA 200 MOUNTING PATTERN USING M6 OR M8 SCREWS:
Attach adapter plate (L) to back of display with four M6 or M8 screws (F, G, H) using hole pattern shown below.
L L
E |
F, G, H |
|
7 of 46 |
ISSUED: 01-27-08 SHEET #: 095-9283-8 01-25-12 |
Attaching Hook Bracket to Display with VESA 75 or 100 Mounting Pattern
WARNING
•If screws don't get three complete turns in the display inserts or if screws bottom out and bracket is still not tightly secured, damage may occur to display or product may fail.
FOR VESA® 75 MOUNTING PATTERN: |
FOR VESA 100 MOUNTING PATTERN: |
3 |
Choose hole pattern as shown below. Attach hook |
|
bracket (K) to back of display using four |
M4 x 10 mm screws (E) as shown below.
Choose hole pattern as shown below. Attach hook bracket (K) to back of display using four
M4 x 10 mm screws (E) as shown below.
K K
E
E
For display compatibility please refer to the fl at panel display interface list on our website www.peerlessmounts.com or call customer care for a display specifi c adapter bracket LC or PLP models (not evaluated by UL).
For Installing to Peerless PLP Model Adapter Plate (not evaluated by UL)
Note: Refer to PLP model adapter plate instruction sheet for attachment of adapter plate to display.
Note: M5 x 10 mm screws are included with the
PLP model adapter plate.
Attach hook bracket (K) to adapter plate using four 3 M5 x 10 mm screws.
K
M5 X 10 mm SCREW
GENERIC ADAPTER PLATE
8 of 46 |
ISSUED: 01-27-08 SHEET #: 095-9283-8 01-25-12 |
Attaching Tilt Knob to Wall Mount (optional)
For tool-less tilt adjustment, replace one 1/4-20 x 4 1/2" screw with tilt knob (D). Drive one 1/4-20 x 1/2"
screw four turns and then remove. Hand thread tilt knob (D) into wall mount (A) leaving 1/4" exposed thread as shown in front view.
NOTE: Be sure four 1/4-20 x 1/2" screws have 1/4" exposed thread.
CAUTION
•Do not tighten screws with excessive force. Overtightening can cause damage to mount. Tighten screws to 20 in. • lb (2.26 N.M.) maximum torque.
•Be careful not to pinch fi ngers when opening and closing mount from the wall.
REPLACE LEFT OR RIGHT 1/4-20 x 1/2" SCREW WITH TILT KNOB
1/4" |
D |
1/4" |
A
FRONT VIEW
Installing and Removing Flat Panel Display
5 |
To attach display to wall mount (A), hook tilt bracket |
onto four 1/4-20 x 1/2" screws. |
Adjust display to desired tilt (15° forward,
5° backward), then tighten four 1/4-20 x 1/2" screws.
Hold display securely to remove from mount. Loosen four 1/4-20 x 1/2" screws and lift display away to disengage tilt bracket from mount.
A
1/4-20 X 1/2" SCREWS
1/4-20 X 1/2" SCREWS
WARNING
• Do not lift more weight than you can handle. Use additional man power or mechanical lifting
equipment to safely handle placement of the display.
9 of 46 |
ISSUED: 01-27-08 SHEET #: 095-9283-8 01-25-12 |
CAUTION
•Do not tighten screws with excessive force. Overtightening can cause damage to mount. Tighten screws to 40 in. • lb (4.5 N.M.) maximum torque.
10-32 x 1/2" screws are pretensioned and require |
1/4-20 X 1/2" SCREWS |
6 no adjustment. Rotate display by hand to level |
|
display. Roll bracket allows 2° roll adjustment. |
|
2° ROLL
ROLL BRACKET
Cord Management
7 |
Attach cable tie anchor (N) to top or bottom of wall |
arm (A) using 8-32 x 1/4" screw (O) as shown. |
O
N
A
7-1 Secure cables to wall arm (A) using cable tie (M).
M
CORD
A
10 of 46 |
ISSUED: 01-27-08 SHEET #: 095-9283-8 01-25-12 |
WARNING
•Do not remove screw or loosen screw until it is no longer engaged with the mount. Doing so may cause the display to fall.
Arm Tension Adjustment
If more or less tension is desired in the arm pivot 8 points, do the following:
•To increase tension, turn tension screw(s).
•To reduce tension, turn tension screw(s).
NOTE: Do not turn tension screws more than half a turn.
TENSION SCREWS
11 of 46 |
ISSUED: 01-27-08 SHEET #: 095-9283-8 01-25-12 |
© 2012, Peerless Industries, Inc. All rights reserved. All other brand and product names are trademarks or registered trademarks of their respective owners.
Peerless Industries, Inc.
2300 White Oak Circle Aurora, Il 60502 www.peerlessmounts.com
Instalación y ensamblaje:
Soporte Giratorio para Pantallas de 22" a 40" (56 - 102 cm)
Models: PA740, PA740-S
Características:
•Sostiene pantallas de 22" a 40" (56 - 102 cm)
•Tiene dos puntos de giro de ajuste tensor para ofrecer una gama de ángulos para ver el televisor
I |
|
D |
|
: |
|
0 |
00 |
76
0018
2
• |
Es compatible con VESA® 75/100/200 x 100/200 x 200 |
Máxima Capacidad de Carga de UL: |
• |
Despeja espacios al plegarse plano contra la pared |
80 lb (36 kg) |
|
||
|
|
|
|
2300 White Oak Circle • Aurora, Il 60502 • (800) 865-2112 |
• Fax: (800) 359-6500 • www.peerlessmounts.com |
|
|
PUBLICADO: 01-27-08 HOJA #: 095-9283-8 01-25-12 |
Español
Nota: Lea la hoja de instrucciones completa antes de comenzar la instalación y el ensamblaje.
ADVERTENCIA
•No comience a instalar su producto de Peerless hasta haber leído y entendido las instrucciones y las advertencias contenidas en la Hoja de Instalación. Si tiene alguna pregunta acerca de cualquiera de las instrucciones o las advertencias, por favor, llame a Servicio al Cliente de Peerless al 1-800-865-2112 si está en EE. UU. Si es un cliente internacional, por favor, comuníquese con su distribuidor local.
•Este producto sólo debe ser instalado por una persona que tenga una buena aptitud mecánica, que tenga experiencia en construcción básica de edifi cios y que entienda estas instrucciones en su totalidad.
•Asegúrese de que la superfi cie de apoyo sostendrá, con seguridad, la carga combinada del equipo y todos los fi jadores y componentes.
•Nunca sobrepase la capacidad máxima de soportar carga aceptada por Underwriters Laboratories. Vea la página 12.
•Si va a instalar el producto en una pared con montantes de madera, asegúrese de que los tornillos de montaje estén anclados en el centro de los montantes. Se recomienda utilizar un localizador de montantes de "borde a borde".
•Siempre cuente con la ayuda de un asistente o utilice un equipo mecánico de izar para levantar y colocar el equipo con más seguridad.
•Apriete los tornillos con fi rmeza, pero no en exceso. Apretarlos en exceso puede dañar los artículos y puede disminuir signifi cativamente su fuerza de fi jación.
•Este producto está diseñado para uso en interiores solamente. Utilizar este producto en exteriores podría causar fallas del producto y lesiones a individuos.
•Este producto fue diseñado para ser instalado en paredes con la siguiente construcción solamente:
CONSTRUCCIÓN DE LA PARED |
ACCESORIOS NECESARIOS |
|
• |
Montante de madera |
Incluido |
• |
Viga de madera |
Incluido |
• |
Concreto macizo |
Incluido |
• |
Bloque de hormigón de escorias |
Incluido |
• |
Montante de metal |
No lo instale excepto con el juego de accesorios de Peerless para |
|
|
montantes de metal (no evaluados por UL) |
• |
Ladrillo |
Comuníquese con un profesional califi cado (no evaluados por UL) |
• |
¿Otra superfi cie o no está seguro? |
Comuníquese con un profesional califi cado |
Herramientas necesarias para el ensamblaje
•localizador de montantes (se recomienda uno de "borde a borde")
•destornillador phillips
•taladro
•broca de 5/16" (8 mm) para paredes de concreto y de bloque de hormigón de escorias
•broca de 5/32" (4 mm) para paredes con montantes de madera
•nivel
Tabla de contenido |
|
Lista de piezas...................................................................................................................................................................... |
14 |
Instalación en una pared con montantes de madera ........................................................................................................... |
16 |
Instalación en una pared de concreto macizo o de bloques de hormigón de escorias........................................................ |
17 |
Fijación de la placa adaptadora a pantallas con confi guraciones de montaje VESA® ......................................................... |
18 |
Instalar en el soporte adaptador modelo PLP de Peerless .................................................................................................. |
19 |
Manejo de cables y ajuste tensor del brazo ......................................................................................................................... |
21 |
13 de 46 |
PUBLICADO: 01-27-08 HOJA #: 095-9283-8 01-25-12 |
Español
Antes de comenzar, asegúrese de que su producto contiene todas las piezas que se muestran.
Lista de piezas
|
|
|
|
PA740 |
PA740-S |
|
|
Descripción |
Cant. N° de pieza |
N° de pieza |
|
|
A soporte para pared |
1 |
095-P1704 |
095-4704 |
|
|
B anclaje de concreto |
2 |
590-0320 |
590-0320 |
|
|
C tornillo de cabeza plana para madera #14 x 2-1/2" |
2 |
520-1202 |
520-2165 |
|
|
D 1/4-20 x 1/2" por la perilla |
1 |
560-1162 |
560-1162 |
|
|
E |
tornillo phillips M4 x 10 mm |
4 |
504-9012 |
520-2027 |
|
F |
tornillo phillips M6 x 12 mm |
4 |
520-1128 |
520-2039 |
|
G |
tornillo phillips M6 x 20 mm |
4 |
520-9402 |
520-2040 |
|
H |
tornillo phillips M8 x 10 mm |
4 |
520-1605 |
520-2605 |
|
I |
tornillo phillips M5 x 6 mm |
4 |
520-1023 |
520-2214 |
|
J |
arandela plana No. 10 |
4 |
540-9400 |
540-9442 |
|
K |
soporte de gancho |
1 |
095-P1346 |
095-4346 |
|
L |
placa adaptadora |
1 |
095-P1721 |
095-4721 |
|
M |
sujetacables |
3 |
560-9711 |
560-2004 |
|
N |
anclaje del sujetacables |
3 |
590-1290 |
590-1290 |
|
O |
tornillo de cabeza plana de 8-32 x 1/4" |
3 |
520-1622 |
520-2622 |
|
P |
espaciadores |
4 |
590-5005 |
590-5003 |
Las piezas pueden verse un poco distintas a la ilustración.
B
D
A
C
K
E F G H I J
L
M N
O
P
14 de 46 |
PUBLICADO: 01-27-08 HOJA #: 095-9283-8 01-25-12 |