Before using your air conditioner, please read
this operating instructions carefully and keep it
for future reference.
Room Air Conditioner
OPERATING INSTRUCTIONS
Before using your air-conditioner, please read this operating instructions
carefully and keep it for future reference.
C
OOLING MODEL
CS-C9CKPG CU-C9CKP6G
CS-C12CKPG CU-C12CKP6G
H
EAT-PUMP MODEL
CS-A9CKPG CU-A9CKP6G
CS-A12CKPG CU-A12CKP6G
:-
Indoor Outdoor
:-
Indoor Outdoor
ENGLISH ....................... P. 1 – P. 11
ESPAÑOL ...................... P. 12 – P. 22
Please register your product at
www.panasonic.com/register
For assistance, please call; (866)-292-7292, for
Hawaii residents call (808)-488-7779.
F563841
Thank you for purchasing our Panasonic Room Air
Conditioner.
CONTENTS
:Features ..................................................... 1
:Safety Precautions .................................... 2
■ Installation Precautions
■ Operation Precautions
:Name of Each Part ................................ 3~4
■ Indoor Unit
■ Outdoor Unit
■ Accessories
■ Remote Control
:Preparation Before Operation .................. 5
■ Indoor Unit
■ Remote Control
:How to Operate ...................................... 5~6
:Setting the Timer ....................................... 7
:Convenience Operation ............................ 7
■ Powerful Mode Operation
■ Economy Mode Operation
■ Quiet Mode Operation
:Care and Maintenance .............................. 8
■ Cleaning the Indoor Unit and Remote Control
■ Cleaning the Air Filter
■ Cleaning the Front Panel
■ Air Purifying Filters
■ Pre-season Inspection
■ When the Air Conditioner is Not Used for an
Extended Period of Time
■ Recommended Inspection
:Helpful Information ................................... 9
:Energy Saving and Operation Hints ........ 9
:Troubleshooting ...................................... 10
■ Normal Operation
■ Abnormal Operation
■ Call the Dealer Immediately
:
Product Specification and Reference
...... 11
FEATURES
● Illuminating Button
For your convenience to operate the unit in the dark.
(Refer page 4)
● Automatic Operation
Sense indoor temperature to select the optimum
mode.
(Refer page 5)
● Quiet Mode
To provide quiet operation.
(Refer page 7)
● Economy Mode
To reduce electrical power consumption.
(Refer page 7)
● Powerful Mode
Reaches the desired room temperature quickly.
(Refer page 7)
● Removable Front Panel
For quick and easy cleaning (washable).
(Refer page 8)
● Air Purifying Filter
This new filter helps trap small airborne particles
such as dust, pollen and tobacco smoke.
(Refer page 8)
● Solar Refreshing Deodorizing Filter
Used to remove unpleasant odor and deodorize the
air in the room.
(Refer page 8)
● Auto Restart Control
Restart the unit automatically after power failure.
(Refer page 9)
! Warning
1) Operate your air conditioner from a stable 115 volts AC
supply.
2) Use a 15 Amps (CS-C9CKPG/CU-C9CKP6G, CSA9CKPG/CU-A9CKP6G) or 20 Amps (CS-C12CKPG/
CU-C12CKP6G, CS-A12CKPG/CU-A12CKP6G) time
delay fuse or a circuit breaker.
3) Disconnect from the main before servicing this
appliance.
4) Do not repair by yourself.
In case of malfunction of this appliance, do not repair by
yourself. Contact the sales dealer or service dealer for
a repair.
5) Turn off the power (Isolation from main power supply).
Switch off the breaker, or switch off the power
disconnecting means to isolate the equipment from the
main power supply in case of an emergency.
POWER SUPPLY
Time Delay Fuse: Rated Volts:
15 Amps : CS-C9CKPG/
CU-C9CKP6G,
CS-A9CKPG/
CU-A9CKP6G
20 Amps : CS-C12CKPG/
CU-C12CKP6G,
CS-A12CKPG/
CU-A12CKP6G
115 V
Note:
Before using your air conditioner, please read
this operating instructions carefully and keep it
for future reference.
1
SAFETY PRECAUTIONS
Before operating, please read the following
“Safety Precautions” carefully.
● To prevent personal injury, injury to others and
property damage, the following instructions must be
followed.
● Incorrect operation due to failure to follow instructions
will cause harm or damage, the seriousness of which
is classified as follow:
■ Installation Precautions
! Warning
● Do not install, remove and reinstall the unit by
yourself.
Improper installation will cause leakage, electric
shock or fire. Please engage an authorized dealer
or specialist for the installation work.
ENGLISH
■ Operation Precautions
! Warning
This sign warns of death or serious injury.
● Do not operate with wet hands.
● Do not insert finger or other objects into the
indoor or outdoor units.
● Do not expose directly to cold air for a long
period of time.
! Warning
This sign warns of death or serious injury.
! Caution
This sign warns of damage to property.
● The instructions to be followed are classified by the
following symbols:
This symbol (with a white background) denotes an
action that is PROHIBITED.
F
F
O
! Caution
● This room air conditioner must be
earthed.
Improper grounding could cause
electric shock.
● Ensure that the drainage piping is
connected properly.
Otherwise, water will leak out.
● Do not install the unit in a
potentially explosive atmosphere.
Gas leak near the unit could cause
fire.
● Use specified power cord.
● If abnormal condition (burnt smell, etc.)
F
F
O
occurs, switch off the power supply.
! Caution
This sign warns of injury.
● Do not wash the unit with water.
● Do not use for other purposes such as
preservation.
● Do not use any combustible equipment at
airflow direction.
● Do not sit or place anything on the outdoor
unit.
● Switch off the power supply before cleaning.
● Ventilate the room regularly.
● Pay attention as to whether the installation
rack is damaged after a long period of usage.
These symbols (with a black background) denote
actions that are COMPULSORY.
O
used for a long period.
2
● Switch off the power supply if the unit is not
F
F
NAME OF EACH PART
■ Indoor Unit
1
L
L
U
U
F
F
L
L
R
R
U
U
E
E
F
F
W
W
R
R
O
O
E
E
P
P
W
W
O
O
P
P
Y
Y
M
M
O
O
Y
Y
N
N
M
M
O
O
O
O
C
C
N
N
E
E
O
O
C
C
E
E
6
1 Front Panel
2 Air Intake Vent
3 Air Outlet Vent
4 Vertical Airflow Direction Louver
5 Horizontal Airflow Direction Louver
(manually adjusted)
6 Indicator Panel
123 654
POWERFULPOWERFUL
ECONOMYECONOMY POWERPOWER
POWERFULPOWERFUL
ECONOMYECONOMY
2
R
R
E
E
M
M
I
I
R
R
T
T
E
E
M
M
I
I
T
T
T
T
E
E
I
I
U
U
T
T
Q
Q
E
E
I
I
U
U
Q
Q
R
R
E
E
W
W
R
R
O
O
E
E
P
P
W
W
O
O
P
P
345
POWERPOWER
● Indoor Unit
■ Accessories
(when the front panel is opened)
● Remote Control
1
2
1 Front Panel
3
A
U
T
O
H
E
A
T
C
ON
O
O
L
A
O
U
F
D
F
T
R
F
O
YFA
N
A
U
Q
FA
TEMP
T
U
O
N
IE
T
MODE
OFF/ON
A
E
I
R
C
S
O
S
tep
N
W
O
I
M
N
Y
1
G
O
N
O
C
H
E
C
K
R
E
S
E
T
SLEEP
2
F
F
FA
N
S
P
E
E
D
3
TIM
S
ET
E
R
C
A
C
N
L
O
C
C
E
K
L
+
B
A
T
T
E
R
Y
● Remote Control Holder
2 Air Filters
3 Air Purifying Filter
■ Outdoor Unit
● Two RO3 (AAA) dry-cell batteries or equivalent
1
6
QUIETQUIET
TIMERTIMER
QUIETQUIET
TIMERTIMER
2
3
● Air Purifying Filter
4
5
1 Auto Operation Button
(when the front panel is opened)
2 Economy Mode Indicator – GREEN
3 Powerful Mode Indicator – ORANGE
4 Power Indicator – GREEN
5 Quiet Mode Indicator – ORANGE
6 Timer Mode Indicator – ORANGE
3
1 Air Intake Vents
2 Ground Terminal
(Inside cover)
3 Piping
4 Conduit
5 Drain Hose
6 Air Outlet Vents
(Air Purifying Filter)
(Solar Refreshing Deodorizing Filter)