OLYMPUS C-1 TECHNICAL INFORMATION TID C1 E009

TECHNICAL INFORMATION
NO. TID-C1-E009
DATE 2001/9/14
SUBJECT: The countermeasure of the fuse cutting
Contents:
Product name:
C-1/D-100
Problem phenomenon:
When a battery is inserted conversely and battery Cover is closed, a circuit short-circuits, and a fuse may blow on the way battery cover is closed and it goes.
Part number
:
PARTS NUMBER DISCRIPTION
DB125800 Fuse
VC177500 COVER BATTERY UNIT [C-1] VC177600 COVER BATTERY UNIT [D-100]
Countermeasure classification:
A countermeasure is enforced in the all repairs goods.
Countermeasure:
Battery Cover is exchanged for countermeasure Cove Battery Unit toward all the accepted repair goods. And, as for the thing that a fuse can cut, it is also exchanged for the fuse too.
Repair parts:
An old part is discontinued. (VE299700, VE352500, VC158800) It will be made the supply of only the countermeasure unit from now on.
The position of the fuse:
In the POWER-PCA (VJ190900)
DB125800 Fuse
OLYMPUS OPTICAL CO.,LTD TOKYO