D. REPAIR PROCEDURE
C-1/D-100
D. REPAIR PROCEDURE
[1] THE FIRMWARE RENEWAL DIRECTIONS DOCUMENT OF VER1.065 .............D-2
1. THE LMITATION ITEM THAT FIRMWARE IS RELATED TO THE WAY OF
REWRITING IT................................................................................................. D-2
2. HOW TO REWRITE FIRMWARE .................................................................... D-2
3. ONE’S PERSONAL HISTORY IN THE FIRMWARE RENEWAL ..................... D-3
4. ABOUT THE DAMAGE INDICATION ................................................................ D-4
D-1
Ver.1
D. REP AIR PROCEDURE
C-1/D-100
[1]The firmware renewal directions document of Ver1.065
1: The limitation item that firmware is related to the way of rewriting it
Firmware to mention in this directions document is based on the upgrade from the following firmware version [ how to
rewrite it ].
B:1023 (Boot : Ver1.023)
Firmware after the renewal becomes the following version.
B:1024 (Boot : Ver1.024)
U:1065 (Executive:Ver1.065)
2: How to rewrite firmware
A part Boot must be Ver1.023 so that it may be upgraded in Ver1.065 from the firmware of the above version.
Confirm the version of the part Boot before the renewal surely.
(Refer to 2-5 clauses for the way of confirming it.)
A body part is written by putting rom4856b.bin and rom4856s.bin in romw_b folder of the renewal card, and it can be
hatched.
A process is shown in the following.
2-1:
rom4856b.bin and rom4856s.bin are put in romw_b folder of the renewal card.
There is no limitation specially as for the renewal card if it is SmartMedia that use is possible with C-1.
2-2:
An AC adapter is connected, and a renewal card is loaded after a battery is taken out from the camera and Cover Lens is
closed.
2-3:
Cover Lens is opened with pushing OK button.
OK button can be left if this is confirmed because orange LED beside Finder becomes lighting condition when renewal
is started.
2-4:
Orange LED goes off when renewal is finished normally.
When LED went off, go to 2-5 and keep conected an AC adapter.
If it fails, buzzer rings with orange LED blinking three times. (Orange LED lasts blinking.)
As for the measure when renewal fails, it is mentioned later. (The following 2-6 clauses)
D-2
Ver.1/Rev.5