OLYMPUS C-1 TECHNICAL INFORMATION TID C1 E005

TECHNICAL INFORMATION
NO. TID-C1-E005
DATE 2001/7/2
SUBJECT: The upgrade of the adjustment software
Product name: C-1/D-100 Change reason
When it takes pictures under the white color fluorescent light, because an image turns yellow after Repair adjustment software "color adjustment".
OLD NEW
C-1 Ver1.0 rev2 C-1 Ver1.1 rev1
Cause The defect of the parameter file for DNP Viewer.
Countermeasure The change of the parameter file for DNP Viewer.
change contents C1_Adj v1.1rev1 Parameter file: The change of BPF_adjust_4856_DNP.csv. ・ Product Number of the camera is inputted at the time of MC BOARD exchange mecashutter
adjustment. (Because a file name isn't kept normally at the time of the adjustment data preservation.) At the time of the MC Board exchange, in the address of product Number of Flash Rom of the camera "00000001" is being written. At the time of Mecashutter adjustment, the product Number calls of the camera. When it is "00000001", the screen of Number writing appears.
Importance :
When color adjustment is done, it drives in viewer with the warmth machine for more than 30 minutes.
reason Because it turns yellow under the white color fluorescent light easily. It is necessary to adjust it under the condition that stabilizes an illuminant to make it hard to turn yellow.
OLYMPUS OPTICAL CO.,LTD TOKYO