NIKON COOLPIX 8800 TECHNICAL INFORMATION

QUALITY ASSURANCE DEPT.
TIE-05049
2005/03/04
H.Masumoto
Mgr
Chf
T.Ogasahara
E8800》Measure against "System Error 2"
Summary
Many reports are received on occurrence of "System Error 2", which takes place when the VR of E8800 malfunctions. This is due to coming-off of the bearing. To prevent this, the countermeasure is as follows:
Contents
1. Details: To prevent the bearing from coming off, which is caused by some shock, additional adhesive (epoxy resin) is added as shown below. The adhesive is applied very slightly on the red-lined parts.
Current adhesive
ADDITIONAL adhesive
Current adhesive
ADDITIONAL adhesive
2. Repairing:
As for items to be repaired, which cause "System Error 2" by the bearing coming off, replace them with
the modied VR unit, or take the below measure. If the phenomenon is not be improved by this, defects
of the VR unit or gyro-PCB, etc should be considered.
3. Procedure:
Up to the stage of separating the lens unit from camera body, refer to Repair Manual.
  ① Take out 4 screws to remove the 1st lens-group tube unit.
P1/3
05F-xxxx
TIE-05049
  ②
Turn the xed-tube B unit
counterclockwise so that the VR unit can be seen. Then take out 2 screws.
Screw
Fixed-tube B unit
  ③ Lift and open the cover of the VR unit in the direction of the arrow, and remove the spring.
Spring
  ④ Then lift and move the VR lens unit in the direction of the arrow, and back the bearing to the normal
position.
    If the bearing came off, check if it isn’t attached on the magnet of the cover.
Note: In case the bearing cannot be found, to avoid the reoccurrence of malfunction, replace
the VR unit.
Bearing
Magnet
Bearing
P2/3
05F-xxxx