Netgear GS116E Installation Manual

Step 1. Connect the equipment.
Access the Switch
Installation Guide
16‑PortGigabit Smart Managed Plus Switch
GS116Ev2
Package Contents
GS116Ev2 switch
WiFi access point
Step 2. Connect power.
Step 3. Check the status.
Network
router
ComputerServer
Sample
connections
Internet
Smart Managed Plus switches are plug-and-play so you do not need to congure them. You can also congure and manage additional advanced features of the
switch either by using a computer’s web browser or by installing the ProSAFE
Plus Conguration Utility on a Windows-based computer.
Web Browser Access
You can congure a switch when it is connected only to your computer
(off-network), or connected to your computer and your network (on-network).
To use your web browser to congure your switch:
1. If you are conguring the switch off-network, record your computer’s TCP/IP conguration settings, and then congure the computer with a static
IP address of 192.168.0.210 and with 255.255.255.0 as the subnet mask.
If you are unsure how to do this, visit netgear.com/support and search for Static IP address on computer.
2. Open a web browser and enter the IP address of the switch.
If the switch is connected to a network with a DHCP server (which usually is a router), use the IP address that the DHCP server assigns to the switch. If the switch is off-network or connected to a network without a DHCP server, use the switch’s default IP address, http://192.168.0.239.
If you are unsure how to determine the IP address of the switch, you can use
the NETGEAR Insight mobile app, ProSAFE Plus Utility, or NETGEAR Switch
Discovery Tool.
Switch (Model GS116Ev2)
AC power adapter (varies by region)
A bag that contains rubber footpads for tabletop installation and a kit for wall-mount installation
Power LED Port LEDs (Speed) Port LEDs (Activity)
On
Off
1000 Mbps link (both LEDs)
100 Mbps link (left LED)
10 Mbps link (right LED)
No link (both LEDs off)
Activity (right LED blinking)
3. Enter the password.
The default password is password.
4. Click the Login button.
You can now congure additional switch settings in the local browser
interface.
5. When you nish conguring an off-network switch, return your computer to its original TCP/IP settings and connect the switch to your network using an
Ethernet cable.
ProSAFE Plus Conguration Utility Access
Find the IP Address Using the NETGEAR Insight Mobile App
Specications
The ProSAFE Plus Conguration Utility runs on Windows-based computers. Visit
www.netgear.com/support/product/PCU to download the latest utility.
To congure the switch by using the ProSAFE Plus Conguration Utility:
1. Unzip and install the ProSAFE Plus Conguration Utility on your computer.
2. Connect your computer to the same network as the switch.
2. Double-click the ProSAFE Plus Utility icon.
The conguration home page displays a list of Smart Managed Plus switches
that the ProSAFE Plus Utility discovers on the local network.
3. Select the switch that you want to congure from the list.
4. When prompted, enter the password.
The default password is password.
5. Use the ProSAFE Plus Utility to congure the switch settings.
For a description of Smart Managed Plus features, see the ProSAFE Plus Conguration Utility User Manual. You can access the user manual through links on the Help tab of the utility.
Note: If an installation problem occurs or you cannot discover the switch when
you use the ProSAFE Plus Utility or NETGEAR Switch Discovery Tool, temporarily disable the rewall, Internet security, or antivirus program, or all of these. After you complete the installation and nish conguring the switch, reenable the
security services on your computer.
Find the IP Address of the Switch Using the NETGEAR Discovery Tool
The NETGEAR Switch Discovery Tool lets you discover the switch in your network and access the local browser interface of the switch from a Mac or a 64-bit Windows-based computer. Download the latest Switch Discovery Tool by visiting
https://www.netgear.com/support/product/netgear-switch-discovery-tool.aspx.
© NETGEAR, Inc., NETGEAR and the NETGEAR Logo
May 2018
are trademarks of NETGEAR, Inc. Any non‑NETGEAR trademarks are used for reference purposes only.
To nd the IP address of the switch by using the Insight mobile app:
1. On your iOS or Android mobile device, visit the app store, search for NETGEAR Insight, and download the latest app.
2. Connect your mobile device to the WiFi network of the router or access point that is connected to the switch.
3. Open the NETGEAR Insight app.
4. If you do not have a NETGEAR account, tap CREATE MYNETGEAR ACCOUNT and follow the onscreen instructions.
5. To log in to your NETGEAR account, tap LOG IN and enter your credentials.
The NETGEAR Insight app can discover the switch and display its IP address.
Support
Thank you for purchasing this NETGEAR product. You can visit
www.netgear.com/support to register your product, get help, access the latest
downloads and user manuals, and join our community. We recommend that you
use only ofcial NETGEAR support resources.
Si ce produit est vendu au Canada, vous pouvez accéder à ce document en français canadien à http://downloadcenter.netgear.com/other/. (If this product is sold in Canada, you can access this document in Canadian French at http://downloadcenter.netgear.com/other/.)
For the current EU Declaration of Conformity, visit
http://kb.netgear.com/11621.
For regulatory compliance information, visit
http://www.netgear.com/about/regulatory/.
Do not use this device outdoors. If you connect cables or devices that are outdoors to this device, see https://kb.netgear.com/000057103 for safety and warranty information.
See the regulatory compliance document before connecting the power supply.
NETGEAR, Inc.
350 East Plumeria Drive San Jose, CA 95134, USA
NETGEAR INTL LTD
Building 3, University Technology Centre Curraheen Road, Cork, Ireland
Specication Description
Network interface RJ-45 connector for 10BASE-T, 100BASE-TX, or 1000BASE-T
Network cable Category 5e (Cat 5e) or higher-rated Ethernet cable
Ports 16
Power 12V @ 1.0 A DC input
Power consumption 10W maximum
Weight 1.86 lb (0.84 kg)
Dimensions (W x D x H) 11.30 in. x 3.98 in. x 1.02 in. (286 mm x 101 mm x 26 mm)
Operating temperature 32° to 104°F (0° to 40°C)
Operating humidity 10%–90% relative humidity, noncondensing