NEC DSX-80 Service Manual

System Conguration
System Configuration
DSX-80/160 System Load Factor
The combination of lines and extensions you can connect to your DSX system may be limited by the System Load Factor. Use the DSX-80/160 System Load Factor Worksheet on the next page to verify your system’s conguration. When entering data on the worksheet, for each installed card make entries for each Load Type. There are two Load Types to consider: 5 VDC and 40 VDC.
To check your system conguration:
1. Indicate the quantity for each card installed in the Qty column.
- The number of keysets, single line sets, and DSS Consoles does not affect the load factor.
2.
For each item and for each Load Type, multiply the
column.
- For example, two 16ESIU Cards have a load of 16 for 5 VDC and 40 for 40 VDC.
3. Add up the entries in each Total column and enter the values in Item 1: Load Type Totals.
4. Review Item 2: Power Supply Capacity and determine the capacity of the power supplies installed in
your system.
5. Compare the capacities in Item 2 to your entries in Item 1. Item 1 must always be equal to or less than
the entry in Item 2.
Do not operate your system if the total for either Load Type
exceeds the Power Supply Capacity of your installation.
Qty
Important
times the
Load
and enter the value in the
Components
Total
DSX-80/160 Hardware Manual Components 19
System Configuration
DSX-80/160 System Load Factor Worksheet
Load Type
Description Qty
Load Total Load Total
5 VDC 40 VDC
CPU Card 1 12 12 0 0
16ESIU Card 8 20
8SLIU Card 5 8
16SLIU Card 10 16
8COIU Card 3 0
16COIU Card 6 0
T1/E1/PRI Card 8 0
(Cannot exceed Item 2: Power Supply Capacity.)
If you have one power supply installed, the capacity is: If you have two power supplies installed, the capacity is: If you have three power supplies installed, the capacity is:
Notes:
Item 1: Load Type Totals
Item 2: Power Supply Capacity
5 VDC = 40 5 VDC = 80 5 VDC = 120
40 VDC = 48 40 VDC = 80 40 VDC = 120
DSX-80 can only have 1 power supply.
DSX-160 can have up to 3 power supplies. You cannot have more than two 16ESIU Cards per power supply,
regardless of System Load Factor calculations.
Exceeding the allowed Load Type Total (Item 1) will cause the system’s power supplies to automatically shut down and/or cause erratic system operation.
The total of all station, line, DSS Console, and voice mail ports cannot exceed 160.
20 Components DSX-80/160 Hardware Manual