Nec DS2000 TO DSX-160, DS2000 TO DSX-80 Upgrading guide

Empowered by Innovation
Upgrading Parts List
Important
DS-Series data bases are not compatible with DSX.
Reference
Cross
Upgrading DS2000
to DSX-80/160
P/N 1093077
Rev 2, June 2006
Printed in U.S.A
01.00.00
.
This manual has been developed by NEC Unified Solutions, Inc. It is intended for the use of its customers and service personnel, and should be read in its entirety before attempting to install or program the system. Any comments or suggestions for improving this manual would be appreciated. Forward your remarks to:
NEC Unified Solutions, Inc.
4 Forest Parkway
Shelton, CT 06484
www.necunifiedsolutions.com
Nothing contained in this manual shall be deemed to be, and this manual does not constitute, a warranty of, or representation with respect to, any of the equipment covered. This manual is subject to change without notice and NEC Unified Solutions, Inc. has no obligation to provide any updates or corrections to this manual. Further, NEC Unified Solutions, Inc. also reserves the right, without prior notice, to make changes in equipment design or components as it deems appropriate. No representation is made that this manual is complete or accurate in all respects and NEC Unified Solutions, Inc. shall not be liable for any errors or omissions. In no event shall NEC Unified Solutions, Inc. be liable for any incidental or consequential damages in connection with the use of this manual. This document contains proprietary information that is protected by copyright. All rights are reserved. No part of this document may be photocopied or reproduced without prior written consent of NEC Unified Solutions, Inc.
©2006 by NEC Unified Solutions, Inc. All Rights Reserved.
Printed in U.S.A.

Table of Contents

Table of Contents
Upgrading . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
DS2000 and DSX-80/160 Compatibility Basics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
How to Use this Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
DS2000 to DSX-80/160 Detailed Compatibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Combined System Load Factor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Upgrade Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Site 1: Upgrade DS2000 4x8 to DSX-80 4x8 with Automated Attendant . . . . . . . . . . . . . . . . 7
Site 2: Upgrade DS2000 8x24 with UltraMail to DSX-80 8x24 and IntraMail . . . . . . . . . . . . 8
Site 3: Upgrade DS2000 16x48 to DSX-160 16x48 with Voice Mail . . . . . . . . . . . . . . . . . . . 9
Site 4: Upgrade DS2000 16x80 (T1) to DSX-160 23x96 (PRI). . . . . . . . . . . . . . . . . . . . . . . 10
DS2000 and DSX-80/160 Parts Lists. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
DS2000 Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
DS2000 Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
DSX-80/160 Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
DSX-80/160 Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
DS-Series to DSX Program Cross Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Cross Reference From DS-Series to DSX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
DS-Series to DSX Cross Reference Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Upgrading DS2000 to DSX-80/160
Table of Contents ◆ i
ii ◆
Table of Contents
Table of Contents
Upgrading DS2000 to DSX-80/160

Overview

Upgrading

Upgrading
Overview

DS2000 and DSX-80/160 Compatibility Basics

When upgrading DS2000 to DSX-80/160, much of the DS2000 station equipment is compatible with the new DSX-80/160 system. This allows the customer to preserve their substantial investment is DS-Series telephones when migrating to the DSX-80/160. Here are some basic upgrade guidelines:
1. The DS2000 4-slot KSU is not compatible with DSX . You must replace the DS2000 4-slot KSU with a DSX-80 KSU. The FCC prohibits the use of DS KSUs with DSX.
2. The DS2000 8-Slot KSU is not compatible with DSX. You must replace the DS2000 8-slot KSU with a DSX-160 KSU. The FCC prohibits the use of DS KSUs with DSX.
3. You must install a DSX CPU Card. The DS CPU PCB cannot run DSX software.
4. You must install a DSX 16 Port Digital Station Card (16ESIU) in KSU port 1. The DSX system will not operate without a 16ESIU PCB in slot 1.
5. To use telephone programming, you must connect at least one DSX telephone. DSX telephones connect only to DSX 16ESIU PCBs.
6. Do not use DS2000 power supplies in DSX-80/160. You must replace all DS2000 power supplies with DSX supplies. The FCC prohibits the use of DS power supplies with DSX.
7. DS-Series telephones must connect to DS 16DSTU PCBs. Install 16DSTU PCBs in any available KSU slot but slot 1.
Upgrading DS2000 to DSX-80/160
Upgrading ◆ 1
Overview

How to Use this Manual

This manual is organized in two chapters as follows.
Upgrading
This is the chapter you are reading now. It provides:
- The compatibility basics (page 1).
- A detailed compatibility chart (page 3).
- The Combined System Load Factor Worksheet (page 6).
- Detailed upgrade examples (page 7).
Parts Lists
For your reference when upgrading, this chapter provides a compete list of parts for both the DS2000 and DSX-80/160 systems.
Cross Reference
Another important tool when upgrading, this chapter consists of a DS-Series to DSX program cross ref­erence. The DS-Series programs are in the left column, followed by the option description, with the cor­responding DSX program in the right column.
2 ◆
Upgrading
Upgrading DS2000 to DSX-80/160

Overview

DS2000 to DSX-80/160 Detailed Compatibility

Overview
Upgrading
(Page 1 of 2)
Comment
Description
DS2000 Telephones
DS2000 to DSX-80/160 Detailed Compatibility Chart
Part
Number
DSX
Compatible
34-Button Super Display Telephone 80673 Yes Must connect to a DS2000 16DSTU PCB.
34-Button Display Telephone 80663
Install the DS 16DSTU PCB in any DSX-80/ 160 KSU slot but slot 1.
22-Button Telephone 80570
22-Button Display Telephone 80573
BDS Cordless Telephone 80683
24-Button DSS Console 80556 No Replace with DSX 60-Button DSS.
110-Button DSS Console 80555
2-OPX Module (Discontinued) 92177A No OPX feature is not available in DSX.
Digital Door Box (Discontinued) 80560 No Replace with DSX Analog Door Box and
2PGDAD Module.
Analog Door Box 92245 Conditional Requires 2PGDAD Module.
Single Line Telephones - Yes Requires DSX 16SLIU PCB or DS2000 4/
8ASTU PCB.
DS2000 Common Equipment
4 Slot KSU 80000 No Replace with DSX-80 KSU.
8 Slot KSU 80001 No Replace with DSX-160 KSU.
Power Supply 80005B/C No Replace with DSX power supply. FCC regula-
tions prohibit the installation of DS2000 power supplies in DSX.
Installation Cable 80892 Yes Compatible.
8-Pin DIN to Mod-8 Cable 80893 No DSX serial port can connect to an SMDR
DB9 to Mod-8 Adaptor 85980 No
device using DSX Serial Adapter 1091014 and a customer provided 6-conductor line cord.
DB25 to Mod-8 Adaptor 85981 No DSX serial port cannot connect to an external
modem.
Modem (CNET CN5614XR) 85862D No Must use DSX built-in modem.
Upgrading DS2000 to DSX-80/160
Upgrading ◆ 3
Overview
4 ◆
(Page 2 of 2)
Comment
PCBs
Description
DS2000 to DSX-80/160 Detailed Compatibility Chart
Part
Number
DSX
Compatible
Central Processing Unit 80025B No Replace with DSX-80/160 CPU.
16DSTU Digital Station PCB 80021A Yes Used for DS telephones on DSX. Install in any
DSX-80/160 KSU slot but slot 1.
16ASTU 16 Port Analog Station PCB 80042 Conditional The hardware is compatible. However, the on-
board rmware must be upgraded to version
1.4 or higher. Contact Sales Support at 800­365-1928 for more.
8ASTU 8 Port Analog Station PCB 80041B Yes DSX 16SLIU provides more stations per PCB.
4ASTU 4 Port Analog Station PCB 80040B Yes
8ATRU 8 Port Analog Trunk PCB 80011B Yes DSX COIU PCB provides superior Caller ID
4ATRU 4 Port Analog Trunk PCB 80010B Yes
detection.
T1 Trunk PCB 80061 Conditional T1 service only. Will not provide PRI when
installed in DSX-80/160.
Voice Mail
DS-Series IntraMail 80045
80089
UltraMail and UltraMail 2000 17712
17714
No
Replace with DSX IntraMail. DS IntraMail CompactFlash card is not compatible with DSX.
No Not tested for compatibility. Replace with DSX
IntraMail.
17744
Analog Voice Mail Conditional NVM-DFx is tested for compatibility with
DSX-80/160 and is recommended.
Digital VANGARD 17770A-
xPDIG
No Not tested for compatibility. Replace with DSX
IntraMail.
Upgrading
Upgrading DS2000 to DSX-80/160

Combined System Load Factor

Understanding System Load Factor
The combination of lines and extensions you can connect to your DSX system may be limited by the System Load Factor. Use the Combined System Load Factor Worksheet chart on the next page to verify your sys­tem’s conguration. When entering data on the chart, for each installed card make entries for each Load
Type . There are two Load Types to consider: 5 VDC and 40 VDC.
To check your system conguration:
1. Indicate the quantity for each card installed in the
- The number of keysets, single line sets, and DSS Consoles does not affect the load factor.
2.
For each item and for each Load Type, multiply the
column.
- For example, two 16ESIU Cards have a load of 16 for 5 VDC and 40 for 40 VDC.
3. Add up the entries in each
4. Review your system.
5. Compare the capacities in the entry in
Item 2: Power Supply Capacity
Item
2
.
Combined System Load Factor
Qty
Total
column and enter the values in
and determine the capacity of the power supplies installed in
Item
2
to your entries in
column.
Qty
Item
times the
1
.
Item
Load
and enter the value in the
Item 1: Load Type Totals
1
must always be equal to or less than
.
Upgrading
Total
Do not operate your system if the total for either Load Type
exceeds the Power Supply Capacity of your installation.
Important
Upgrading DS2000 to DSX-80/160
Upgrading ◆ 5
Combined System Load Factor
DS2000 and DSX-80/160 Combined System Load Factor Worksheet
Load Type
6 ◆
Description Qty
Load
5 VDC 40 VDC
Total Load Total
DSX-80/160 CPU Card 1 12 12 0 0
DSX-80/160 16ESIU Card 8 20
DS2000 16DSTU PCB 3 20
DSX-80/160 8SLIU Card 5 8
DSX-80/160 16SLIU Card 10 16
DS2000 4ASTU PCB 3 5
DS2000 8ASTU PCB 5 8
DSX-80/160 8COIU Card 3 0
DSX-80/160 16COIU Card 6 0
DS2000 4ATRU PCB 4 0
DS2000 8ATRU PCB 8 0
DSX-80/160 T1/PRI Card 8 0
(Cannot exceed Item 2: Power Supply Capacity.)
Item 1: Load Type Totals
Item 2: Power Supply Capacity
If you have one power supply installed, the capacity is: If you have two power supplies installed, the capacity is: If you have three power supplies installed, the capacity is:
Notes:
5 VDC = 40 5 VDC = 80 5 VDC = 120
40 VDC = 48 40 VDC = 80 40 VDC = 120
DSX-80 can only have 1 power supply.
DSX-160 can have up to 3 power supplies. You cannot have more than two 16ESIU or 16DSTU Cards per power supply, regardless of System Load Factor calculations.
Exceeding the allowed Load Type Total (Item 1) will cause the system’s power supplies to automatically shut down and/or cause erratic system operation.
The total of all station, line, and DSS Console ports cannot exceed 160.
Upgrading
Upgrading DS2000 to DSX-80/160

Upgrade Examples

Upgrade Examples

Site 1: Upgrade DS2000 4x8 to DSX-80 4x8 with Automated Attendant

Site 1 wants to upgrade to DSX 22-button telephones and add an Automated Attendant, but does not require voice mail.
Existing DS2000 Equipment Upgrade Requirements for DSX
Description
(1) DS 4ATRU PCB 80010B Compatible - replacement not required. DSX 16COIU PCBs provide
(1) DS 16DSTU PCB 80021A Not required. Since Site 1 has two spare slots,
(8) DS 22-Button Tele-
phone (non-display)
(1) DS 4-Slot KSU 80000 Must be replaced. DS KSUs are prohibited by FCC
(1) DS Power Supply 80005C Must be replaced. DS power supplies are prohib-
(1) DS CPU 80025B Must be replaced.
New DSX Equipment Required
Summary:
To upgrade, in addition to DSX telephones Site 1 must invest in a new DSX-80 KSU, DSX Power Supply, DSX CPU Card, and DSX 16ESIU PCB.
As a benet, the existing DS telephones and DS 16DSTU PCB can be kept on hand for future expansion.
Part Number Description Part Number Comments
more accurate Caller ID detec­tion.
the DS 16DSTU can be moved from slot 1 and used with the DS telephones.
80570 Not required. DS telephones can however, be
used if DS 16DSTU is installed.
in DSX
ited by FCC in DSX.
The DS CPU is not compatible with DSX.
(1) DSX-80 KSU 1090002 Required in DSX.
(1) DSX Power Supply 1091008 Required in DSX.
DSX CPU Card 1090010 Required in DSX.
Built-in Automated Atten­dant is available by default, without adding voice mail.
(1) DSX 16ESIU Card 1090004 Required in DSX.
DSX 16ESIU is required in slot 1 for DSX telephones.
(8) DSX 22-Button
Button Display Tele-
phone
1090020
(Black) or
1090025
These telephones have a 3x24 display.
(White)
Upgrading
Upgrading DS2000 to DSX-80/160
Upgrading ◆ 7
8 ◆
Upgrade Examples

Site 2: Upgrade DS2000 8x24 with UltraMail to DSX-80 8x24 and IntraMail

Site 2 wants the features of the DSX IntraMail but doesn’t want to invest in new telephones.
Existing DS2000 Equipment Upgrade Requirements for DSX
Description
(1) DS 8ATRU PCB 80011B Compatible - replacement not required. DSX 16COIU PCBs provide
(2) DS 16DSTU PCB 80021A Compatible - but only 1 DS 16DSTU can
(24) DS 22-Button Dis-
play Telephone
(1) DS 4-Slot KSU 80000 Must be replaced. DS KSUs are prohibited by FCC
(1) DS Power Supply 80005C Must be replaced. DS power supplies are prohib-
(1) DS CPU 80025B Must be replaced.
(1) 2 Port 3 Hour
UltraMail
New DSX Equipment Required
Summary:
To upgrade, Site 2 must invest in a new DSX-80 KSU, DSX Power Supply, DSX CPU Card, DSX 4x8 IntraMail, and a DSX 16ESIU PCB.
Site 2 must also add eight new DSX telephones. This is required because only one DS DSTU PCB remains, supporting 16 DS telephones.
Site 2 can alternately do the following:
- Replace the DSX-80 4-Slot KSU with and DSX-160 8-Slot KSU.
- Purchase another DSX Power Supply (due to Load Factor considerations).
- Install the 16DSTU PCBs in the new DSX KSU for connecting their existing DS keysets.
- Purchase a single DSX 22-Button Display Telephone for programming, and connect it to the DSX 16ESIU PCB.
Part Number Description Part Number Comments
more accurate Caller ID detec­tion.
DX requires a 16ESIU in slot 1.
be installed in the new DSX system.
80573 Compatible - but only 16 DS telephones
can be used in the new DSX system.
17712 Must be replaced. UltraMail not supported in DFX
(1) DSX-80 KSU 1090002 Required in DSX.
(1) DSX Power Supply 1091008 Required in DSX.
(1) DSX CPU Card 1090010 Required in DSX.
(1) DSX 4x8 IntraMail 1091011 IntraMail CompactFlash Card
(1) DSX 16ESIU Card 1090004 Required in DSX.
(8) DSX 22-Button
Button Display Tele-
phone
1090020
(Black) or
1090025
(White)
Load Factor allows only 1 DS 16DSTU to be installed. 8 DS
telephones must be replaced.
With only 1 DS 16DSTU allowed,
8 DS telephones must be replaced with DSX telephones.
in DSX.
ited by FCC in DSX.
The DS CPU is not compatible with DSX.
and Site 1 wants IntraMail.
plugs into DSX CPU.
DSX 16ESIU is required in slot 1 for DSX telephones.
Eight of the existing DS tele­phones must be replaced because only 1 DS 16DSTU remains installed.
Upgrading