The information disclosed in this document, including all designs and related materials, is the
valuable property of NEC Corporation (NEC) and /or its licensors. NEC and/or its licensors, as
appropriate, reserve all patent, copyright and other proprietary rights to this document, including all
design, manufacturing, reproduction, use, and sales rights thereto, except to the extent said rights are
expressly granted to others.
The NEC product(s) discussed in this document are warranted in accordance with the terms of the
Warranty Statement accompanying each product. However, actual performance of each such
product is dependent upon factors such as system configuration, customer data, and operator control.
Since implementation by customers of each product may vary, the suitability of specific product
configurations and applications must be determined by the customer and is not warranted by NEC.
To allow for design and specification improvements, the information in this document is subject to
change at any time, without notice. Reproduction of this document or portions thereof without prior
written approval of NEC is prohibited.
First Printing, April 2009
Copyright 2009
NEC Corporation
7-1 Shiba 5-Chome, Minato-Ku
Tokyo 108-8001, Japan
All Rights Reserved
Printed in Japan
Keep this User's Guide at hand for quick reference at anytime necessary.
SAFETY INDICATIONS
Follow the instructions in this User's Guide for your safety to use the server.
The server contains components with possible danger, hazards that may cause by ignoring warnings,
and preventive actions against such hazards.
Server components with possible danger are indicated with a warning label placed on or around them
as well as described in this User's Guide.
In the User's Guide or warning labels, "WARNING" or "CAUTION" is used to indicate a degree of
danger. These terms are defined as follows:
WARNING
CAUTION
Precautions and notices against hazards are presented with one of the following three symbols. The
individual symbols are defined as follows:
This symbol indicates the presence of a hazard if the instruction is ignored.
An image in the symbol illustrates the hazard type. (Attention)
This symbol indicates prohibited actions. An image in the symbol illustrates a particular
prohibited action. (Prohibited Action)
This symbol indicates mandatory actions. An image in the symbol illustrates a
mandatory action to avoid a particular hazard. (Mandatory Action)
(Example)
(Example)
Symbol to draw attention
Indicates the presence of a hazard that may result in death or serious
personal injury if the instruction is ignored.
Indicates the presence of a hazard that may cause minor personal injury,
including burns, or property damage if the instruction is ignored.
Description of a dangerTerm indicating a degree of danger
CAUTION
Plug in to a proper power source.
Use a proper wall outlet. Use of an improper power source may cause a fire or a
power leak.
Symbols used in this User's Guide and warning labels are listed below.
Attentions
Indicates that improper use may cause an electric shock.
Indicates that improper use may cause fumes or fire.
Indicates that improper use may cause fingers to be caught.
Indicates that improper use may cause personal injury by the moving fan blades.
Indicates that improper use may cause personal injury.
Indicates that improper use may cause explosion.
Indicates a general notice or warning that cannot be specifically identified.
Prohibited Actions
Do not disassemble, repair, or modify the server. Otherwise, an electric shock or fire
may be caused.
Do not touch any component other than specified. Otherwise, an electric shock or
personal injury such as burns may be caused.
Keep away from fire. Otherwise, an ignition may be caused.
Keep away from water or liquid. Otherwise, an electric shock or fire may be caused.
Indicates a general prohibited action that cannot be specifically identified.
Mandatory Action
Unplug the power cord of the server. Otherwise, an electric shock or fire may be
caused.
Indicates a mandatory action that cannot be specifically identified. Make sure to follow
the instruction.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction manual, may cause harmful interference to
radio communications. Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at his own expense.
BSMI Statement (N8400-086F/087F/088F/089F/090F)
CE Mark Statement
Australia EMI:
NOTE: This is a Class A product. In domestic environment, this product may cause radio
interference in which case the user may be required to take adequate measures.
Canada EMI:
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing
Equipment Regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel
brouilleur du Canada.
Trademarks
NEC ESMPRO and NEC EXPRESSBUILDER are trademarks of NEC Corporation.
Microsoft, Windows, Windows Server, Windows NT, and MS-DOS are registered trademarks or trademarks of Microsoft
Corporation in the United States and other countries.
Intel and Pentium are registered trademarks of Intel Corporation.
Datalight is a registered trademark of Datalight, Inc.
ROM-DOS is a trademark of Datalight, Inc.
AT is a registered trademark of International Business Machines Corporation in the United States and other countries.
LSI and the LSI logo design are trademarks or registered trademarks of LSI Corporation.
Adaptec and its logo is a registered trademark of Adaptec, Inc. of United States.
SCSISelect is a trademark of Adaptec, Inc. of the United States.
Adobe, Adobe logo, and Acrobat are trademarks of Adobe Systems Incorporated.
All other product, brand, or trade names used in this publication are the trademarks or registered trademarks of their
respective trademark owners.
Windows Server 2008 stands for Microsoft® Windows Server® 2008 Standard Operating system and Microsoft® Windows
Server® 2008 Enterprise operating system. Windows Server 2003 x64 Editions stands for Microsoft® Windows Server
2003 R2, Standard x64 Edition operating system and Microsoft® Windows Server® 2003 R2, Enterprise x64 Edition
operating system, or Microsoft® Windows Server® 2003, Standard x64 Edition operating system and Microsoft® Windows
Server® 2003, Enterprise x64 Edition operating system. Windows Server 2003 stands for Microsoft® Windows Server
2003 R2, Standard Edition operating system and Microsoft® Windows Server® 2003 R2, Enterprise Edition operating
system, or Microsoft® Windows Server® 2003, Standard Edition operating system and Microsoft® Windows Server® 2003,
Enterprise Edition operating system. Windows XP x64 Edition stands for Microsoft® Windows® XP Professional x64
Edition operating system. Windows XP stands for Microsoft® Windows® XP Home Edition operating system and
Microsoft® Windows® XP Professional operating system. Windows 2000 stands for Microsoft® Windows® 2000 Server
operating system and Microsoft® Windows® 2000 Advanced Server operating system, and Microsoft® Windows® 2000
Professional operating system. Windows NT stands for Microsoft® Windows NT® Server network operating system version
3.51/4.0 and Microsoft® Windows NT® Workstation operating system version 3.51/4.0. Windows Me stands for Microsoft
Windows® Millennium Edition operating system. Windows 98 stands for Microsoft® Windows®98 operating system.
Windows 95 stands for Microsoft® Windows®95 operating system. WinPE stands for Microsoft® Windows® Preinstallation
Environment.
®
®
®
Momentary voltage drop prevention:
This product may be affected by a momentary voltage drop caused by lightning. To prevent a
momentary voltage drop, an AC uninterruptible power supply (UPS) unit should be used.
Notes:
(1) No part of this manual may be reproduced in any form without the prior written permission of
NEC Corporation.
(2) The contents of this User's Guide may be revised without prior notice.
(3) The contents of this User's Guide shall not be copied or altered without the prior written
permission of NEC Corporation.
(4) All efforts have been made to ensure the accuracy of all information in this User's Guide. If
you notice any part unclear, incorrect, or omitted in this User's Guide, contact the service
representative where you purchased this product.
(5) NEC assumes no liability arising from the use of this product, nor any liability for incidental or
consequential damages arising from the use of this User's Guide regardless of Item (4).
PREFACE
Welcome to the NEC Express5800/BladeServer series server.
The NEC Express5800/BladeServer holds powerful performance and employs the latest technology
to implement a computer for the next generation. With its potential capabilities, the server may be
used as the workstation PC that configures a client-server system and provides high-speed
processing and superior reliability.
Read this User's Guide thoroughly to fully understand handling of the server and appreciate its
functions to the maximum extent.
i
ii
ABOUT THIS USER'S GUIDE
This User's Guide is a guide for proper setup and use of the server.
This User's Guide also covers useful procedures for dealing with difficulties and problems that may
arise during setup or operation of the server.
Keep this manual for future use.
The following describes how to proceed with this User's Guide.
How to Use This User's Guide
To aid you in finding information quickly, this User's Guide contains the following information:
Chapter 1 Notes on Using Your Server
includes information that needs attention to use the CPU blade. Make sure to read this
chapter before setting up and using the CPU blade. It also includes requirements and
advisory information for transfer and disposal of the CPU blade.
Chapter 2 General Description
includes information necessary to use the CPU blade, such as names and functions of its
components.
Chapter 3 Setting Up Your Server
tells you how to select a site, unpack the system, make cable connections, and power on
your system.
Chapter 4 Configuring Your Server
tells you how to configure the system and provides instructions for running the BIOS Setup
Utility and the LSI Software RAID Configuration Utility, which is used to configure RAID drive
in your system.
Chapter 5 Installing the Operating System
describes how to install the operating system.
Chapter 6 Installing and Using Utilities
describes how to install the utilities for the server. It also includes a description on using the
attached "NEC EXPRESSBUILDER" DVD.
Chapter 7 Maintenance
provides you with all the information necessary to maintain successful operation of the CPU
blade.
Chapter 8 Troubleshooting
contains helpful information for solving problems that might occur with your system.
Chapter 9 Upgrading Your Server
provides you with instructions for upgrading your system with an additional processor,
optional memory, and optional mezzanine cards.
Appendix A Specification
provides specifications for your CPU blade.
Appendix B Installing the Operating System
describes how to install Microsoft Windows Server 2008, Microsoft Windows Server 2003
x64 Editions, and Windows Server 2003 without using Express Setup.
Text Conventions
The following conventions are used throughout this User's Guide. For safety symbols, see
"SAFETY INDICATIONS" provided earlier.
iii
IMPORTANT:
NOTE:
Items that are mandatory or require attention when using the server
Helpful and convenient piece of information
IN THE PACKAGE
The carton contains various accessories, as well as the server itself. See the packing list to make
sure that you have everything and that individual components are not damaged. If you find any
component missing or damaged, contact your service representative.
Store the provided accessories in a designated place for your convenience. You will need
them to install an optional device or troubleshoot the server, as well as to set it up.
Make a backup copy of each provided floppy disk, if any. Store the original disk as the
master disk in a designated place, and use its copy.
Improper use of any provided floppy disk or CD-ROM may alter your system
environment. If you find anything unclear, immediately ask your service representative for
help.
Setting Receive Side Scaling..................................................................................................... B-47
Re-installation of the Network Driver ....................................................................................... B-48
The procedure to set PAE option ........................................................................................... B-50
Setting for Solving Problems..................................................................................................... B-52
Setting for Collecting Memory Dump (Debug Information) ................................................ B-52
Re-installing the Operation System if Multiple Logical Drives Exist................................... B-52
Updating the System - Applying Service Pack -........................................................................ B-54
Local Update ......................................................................................................................... B-55
Update from TS Client (Windows Server 2008) ................................................................... B-63
Update from TS Client (Windows Server 2003 x64 Editions) .............................................. B-64
Update from TS Client (Windows Server 2003) ................................................................... B-67
About Windows Activation ................................................................................................... B-70
viii
(This page is intentionally left blank.)
Chapter 1
Notes on Using Your Server
This chapter includes information necessary for proper and safe operation of the server.
1-2 Notes on Using Your Server
SAFETY NOTES
This section provides notes on using the server safely. Read this section carefully to ensure proper
and safe use of the server. For symbols, see "SAFETY INDICATIONS" provided earlier.
WARNING
Do not use the server for services where critical high availability may directly
affect human lives.
The server is not intended to be used with or control facilities or devices
concerning human lives, including medical devices, nuclear facilities and
devices, aeronautics and space devices, transportation facilities and devices;
and facilities and devices requiring high reliability. NEC assumes no liability
for any accident resulting in personal injury, death, or property damage if the
server has been used in the above conditions.
Do not disassemble, repair, or alter the server.
Never attempt to disassemble, repair, or alter the server on any occasion
other than described in this User's Guide. Failure to follow this instruction may
cause an electric shock or fire as well as malfunctions of the server.
Do not remove the lithium battery.
The server contains the lithium battery. Do not remove the battery. Placing
the lithium close to a fire or in the water may cause an explosion.
When the server does not operate appropriately due to the dead lithium
battery, contact your service representative. Do not disassemble the server to
replace or recharge the battery by yourself.
Do not use the server if any smoke, odor, or noise is present.
If smoke, odor, or noise is present, immediately turn off the system and
disconnect the power plug from the outlet, then contact your service
representative. Using the server in such conditions may cause a fire.
Keep needles or metal objects away from the server.
Do not insert needles or metal objects into ventilation holes in the server.
Doing so may cause an electric shock.
Use the devices only in the specified areas.
CPU blades and Storage and I/O Blades should be installed in the dedicated
Blade Enclosure for their uses. Do not install the CPU blades and Storage
and I/O Blades in a chassis other than the Blade Enclosure. Failure to follow it
may result in fire and/or electric shock to occur.
Notes on Using Your Server 1-3
WARNING
Do not handle the CPU blade if it is installed in the Blade Enclosure.
To install or remove an option from the CPU blade, first turn off the power of
the CPU blade and remove the CPU blade from the Blade Enclosure. If you
touch parts on the CPU blade with it connected to the Blade Enclosure, you
may get an electric shock.
Do not install or remove more than one CPU blade at a time.
Install or remove CPU blades one by one. If you install or remove more than
one CPU blade at a time or a CPU blade with the cover of another slot
removed, you may be electrically shocked.
Do not use the equipment in the place where corrosive gases exist.
Make sure not to locate or use the server in the place where corrosive gases
(sulfur dioxide, hydrogen sulfide, nitrogen dioxide, chlorine, ammonia, ozone,
etc) exist.
Also, do not set it in the environment where the air (or dust) includes
components accelerating corrosion (ex. sulfur, sodium chloride) or conductive
metals. There is a risk of a fire due to corrosion and shorts of an internal
printed board.
CAUTION
Keep water or foreign matter away from the CPU blade.
Do not let any form of liquid (water etc.) or foreign matter (e.g., pins or paper
clips) enter the server. Failure to follow this warning may cause an electric
shock, a fire, or a failure of the server. When such things accidentally enter
the server, immediately turn off the power and disconnect the power plug
from the outlet. Do not disassemble the server. Contact your service
representative.
Make sure to complete device installation.
Always install a CPU blade, Storage and I/O Blade, and board firmly. An
incompletely installed device may cause a contact failure, resulting in
smoking or fire.
Do not use any unauthorized interface cable.
Use only interface cables provided by NEC and locate a proper device and
connector before connecting a cable. Using an authorized cable or
connecting a cable to an improper destination may cause a short circuit,
resulting in a fire.
Also, observe the following notes on using and connecting an interface cable.
Do not use any damaged cable connector.
Do not step on the cable.
Do not place any object on the cable.
Do not use the Blade Enclosure with loose cable connections.
1-4 Notes on Using Your Server
Avoid installation in extreme temperature conditions.
Immediately after the server is powered off, its internal components are very
hot. Leave the server until its internal components fully cool down before
installing/removing any component.
Avoid contact with the server during thunderstorms.
Disconnect the power plug from the outlet when a thunderstorm is
approaching. If it starts thundering before you disconnect the power plug, do
not touch any part of the server including the cables. Failure to follow this
warning may cause a fire or an electric shock.
Keep animals away from the server.
Pet's discharges or fur may enter the CPU blade and cause a fire or electric
shock.
CAUTION
Notes on Using Your Server 1-5
FOR PROPER OPERATION
Observe the following notes for successful operation of the server. Use of the server ignoring the
notes will cause malfunctions or failures of the server.
CPU blade
– N8400-086F/087F/088F/089F/090F CPU blade assembly can be installed in the Blade
Enclosure (SIGMABLADE).
– Install or remove CPU blades one by one.
– Hold the portions covered with metal plates when a CPU blade is installed or removed.
To carry a CPU blade, put it into the case in which the CPU blade was contained at the
purchase and pack it into the package.
– The CPU blade is extremely sensitive to static electricity. Make sure to touch the metal
frame of the server to discharge static electricity from your body before handling the
CPU blade. Do not touch the CPU blade terminals or on-board parts by a bare hand and
place the CPU blade directly on the desk.
– Check and adjust the system clock before the operation if any of the following
conditions is applicable.
After carriage of device
After storage of device
After the device is entered into the pause state under the environmental
20% - 80%)
Check the system clock at the rough rate of once per month. When the system clock is
installed in a system requiring high time precision, it is recommended to use a time
server (NTP server).
If the system clock is remarkably delayed or advanced as the passage of time in spite of
adjustment, contact your service representative to ask maintenance.
– Store the unit under the storage condition (temperature: -10°C - 55°C, humidity: 20% -
80%, without condensation) to allow built-in devices and the unit to operate correctly
in the next operation.
– Before turning off the power of a CPU blade, shut down the CPU blade correctly.
– Turn on the power of each CPU blade by the use of the POWER switch or the remote
power-on after the period of 30 seconds or longer has passed from the supply of AC
power (the POWER lamp of the CPU blade goes on amber) to every power unit. The
power of the CPU blade may not be turned on if the power-on operation is done within
the period of less than 30 seconds from the supply of AC power. After making sure that
the AC power is supplied to every power unit, turn on the power of each CPU blade by
using the POWER switch.
– After turning off the power of a CPU blade once, turn on the power again after 30
seconds have passed from the power-off.
– Remove a CPU blade after turning off the power of the CPU blade.
1-6 Notes on Using Your Server
– The CPU blade contains precision component that is easily affected by drastic
temperature change. If the CPU blade is used after storage or relocation, make sure that
the CPU blade is fully adapted to the operating environment.
– Make sure that the options are optional devices for the purchased blade server. If an
option can be installed or connected to the CPU blade, the option may not operate
properly and further the CPU blade may be defected.
– Do not perform any of the following operation during POST (including similar
operations from EM card and external applications).
Press the POWER switch of the CPU blade.
Press the RESET switch of the CPU blade.
Remove the CPU blade from the Blade Enclosure.
Disconnect the power cord from the power unit of the Blade Enclosure.
Optional memory, processor, mezzanine card, board, and other electronic components
– These components are extremely sensitive to static electricity. Make sure to touch the
metal frame of the server to discharge static electricity from your body before handling
the components. Do not touch the terminals or parts on the components by a bare hand
and place the components directly on the desk.
– Make sure that the options are optional devices for the purchased blade server. If an
option can be installed or connected to the server, the option may not operate properly
and further the server itself may be defected.
– The internal option device contains precision component that is easily affected by
drastic temperature change. If the device is used after storage or relocation, make sure
that the device is fully adapted to the operating environment.
– It is recommended to use options provided by NEC. Some memory devices of other
vendors are designed to be available for the server. If such an option causes the server
to be defected or damaged, you will be charged for the repair within the warranty
period.
Do not use a cellular phone or pager around the server.
Turn off the cellular phone or pager. Radio interference may cause malfunctions of the
server.
Notes on Using Your Server 1-7
TRANSFER TO THIRD PARTY
The following must be observed when you transfer (or sell) the server or software provided with the
server to a third party:
Server
Make sure to provide this manual along with the server to a third party.
Provided Software
To transfer or sell any software application that comes with the server to a third party, the following
requirements must be satisfied:
All provided software applications must be transferred and no backup copies must be
retained.
Transfer requirements listed in "Software License Agreement" that comes with each
software application must be satisfied.
Software applications that are not approved for transfer must be uninstalled before
transferring the server.
1-8 Notes on Using Your Server
DISPOSAL AND CONSUMABLES
Dispose of the CPU blade, Storage and I/O Blades, Blade Enclosure, option board, floppy
disks, and CD/DVD-ROMs according to all national laws and regulations. Also dispose of
the power cord provided with the server to avoid diversion to some other devices.
IMPORTANT:
For disposal (or replacement) of the battery on the mother board of
the server, consult with your service representative.
It is the user's responsibility to completely erase or modify all the
data stored in storage device so that the data cannot be restored.
The server contains some components that are only good for a limited period of time and
require replacement. For stable operation of the server, NEC recommends you replace
these components on a regular basis. Consult with your service representative for
replacement or the product lives.
WARNING
Do not remove the battery.
The server contains the lithium battery. (Some option devices contain lithium
battery, nickel cadmium battery, or nickel hydrogen battery.) Do not remove
the battery. Placing the lithium, nickel cadmium, or nickel hydrogen battery
close to a fire or in the water may cause an explosion.
When the server does not operate appropriately due to the dead lithium
battery, contact your service representative. Do not disassemble the server to
replace or recharge the battery by yourself.
Notes on Using Your Server 1-9
USER SUPPORT
Before Asking for Repair, do the following when the server appears to fail:
1. Check if the power cord and the cables to other devices are properly connected.
2. See Chapter 8 to find if your problem fits the description. If it does, take the
recommended measure for it.
3. Check if the software required for operation of the server is properly installed.
If the server still appears to fail after you have taken the above actions, consult with your service
representative immediately. Take notes on lamp indications of the server and alarm indications on
the display unit before consultation, which may provide a significant help to your service
representative.
1-10 Notes on Using Your Server
Advice for Health
The longer you keep using the computer equipment, the more you become
tired, which may cause disorders of your body. When you use a computer,
observe the following to keep yourself from getting tired:
Good Working Posture
You have good posture if the following are satisfied when you use a
computer:
• You sit on a chair with your back straight.
• Your hands are parallel with the floor when you put them on the
keyboard.
•You look at the screen slightly lower than your eye height.
You have "good working posture" as described in the above when no part
of your body is under excess strain, in other words when your muscles are
most relaxed.
You have "bad posture" when you sit with your back hunched up or you
operate a display unit with your face close to the screen. Bad working
posture may cause eye strain or poor eyesight.
Adjustment of Display Unit Angles
Most display units are designed for adjustment of the horizontal and
vertical angles. This adjustment is important to prevent the screen from
reflecting bright lights and to make the display contents easy to see. You
will not be able to keep "good working posture" and you will feel more tired
than you should if you operate a display unit without adjusting horizontal
and vertical angles.
Adjustment of Screen Brightness and Contrast
The display unit has brightness and contrast adjustment functions. The
most suitable brightness and contrast depend on the individual and the
working environment (well-lighted room or insufficient light). Adjust
brightness and contrast so that the screen will be easy to see. An
extremely bright or dark screen will give a bad effect to your eyes.
Adjustment of Keyboard Angle
The keyboard provided with the server is designed for adjustment of an
angle. Adjust the keyboard angle at which the keyboard is easy to operate.
The adjustment assists in reducing strain on your shoulders, arms, and
fingers.
Cleaning of Equipment
Clean equipment regularly. It is difficult to see the display contents on a
dusty screen. Keeping equipment clean is also important for your sight.
Fatigue and Rest
If you feel tired, you should stop working and do light exercises.
Chapter 2
General Description
This chapter provides information that you should be familiar with before using the server. It
includes names and functions of the components and features of the server.
2-2 General Description
OVERVIEW
BladeServer is a modular and multiprocessing system that includes processor, memory, network
connections, optional add-in card slot, and associated electronics, all on a single mother board called
a CPU blade.
The CPU blade, Storage and I/O Blade, and other CPU blades are typically installed into a rackmountable enclosure that houses multiple CPU blades that share common resources such as cabling,
power supplies, and cooling fans.
This high-density technology reduces the installation space, lowers a total cost of ownership, and
offers increased computing density while ensuring both maximum scalability and ease of
management.
Power On Self-Test (POST)
Test and Diagnosis (T&D)
Easy and Fine Setup
NEC EXPRESSBUILDER (system
management tools)
SETUP (BIOS setup utility)
2-4 General Description
PART NAMES AND CONTROLS
This section describes the names and features of the sections in the device.
CPU Blade
This section describes the names, installation positions, and features of the sections on the CPU
blade.
Onboard Components
1
9
8
7
1DIMM socket (CPU #1)
CPU1_DIMM1, CPU1_DIMM4, CPU1_DIMM2, CPU1_DIMM5, CPU1_DIMM3, and
CPU1_DIMM6 from top
2Socket cover
Install the processor #2 (CPU #2) below this socket cover.
3Lithium battery
4Type 2 mezzanine slot
Slot to install mezzanine card for blade. The slot number is "MEZ2".
5Type 1 mezzanine slot
Slot to install mezzanine card for blade. The slot number is "MEZ1".
6DIMM socket (CPU #2)
CPU2_DIMM1, CPU2_DIMM4, CPU2_DIMM2, CPU2_DIMM5, CPU2_DIMM3, and
CPU2_DIMM6 from bottom
7Heat sink
Install the processor #1 (CPU #1) below this heat sink.
8SUV connector
9Eject lever
23
6
4
5
CPU Blade Access Side
10
11
General Description 2-5
1
2
3
4
5
6
7
8
9
1
2
ID
1 POWER lamp
The lamp goes on green when the CPU blade is powered on.
The lamp goes on amber when the CPU blade is powered off but the power is supplied from
the power supply unit.
2 POWER switch
The switch is intended to turn on or off the power of the CPU blade itself. Pressing the switch
for 4 seconds or longer causes the power supply to be turned off forcibly.
3 STATUS lamp (green/amber/red)
The lamp indicates the status of the CPU blade. See "Lamp Indications" described later for
the indications and meanings of the lamp.
4 DUMP switch
Press this switch to run the memory dump.
5 LAN1 Link/Access lamp (green)
The lamp goes on when LAN port 1 is connected to the network. The lamp blinks when data
is being transmitted.
6 RESET switch
Press this switch to reset the CPU blade.
7 LAN2 Link/Access lamp (green)
The lamp lights when LAN port 2 is connected to the network. The lamp blinks when data is
being transmitted.
2-6 General Description
8ID switch
Press this switch to turn on or off the ID lamp.
9 ID lamp (blue)
The lamp is intended to identify the CPU blade in the system. The lamp is lit by a switch or
software command.
When the recognize command is received from software, the lamp blinks. If you press the ID
switch, the lamp goes on.
You may use the remote control feature of EXPRESSSCOPE Engine 2 (BMC) to perform the
same operation as using the ID switch on the server.
10 Eject lever
Pull the lever to remove the CPU blade from the Blade Enclosure.
11 SUV connector
This connector sends or receives various signals.
The K410-150(00) SUV cable is connected to this connector.
External View
General Description 2-7
Top cover
CPU blade with its cover installed
Air duct cover
CPU blade with its cover removed
CPU blade with its air duct cover removed
2-8 General Description
Lamp Indications
This section describes the positions and display meanings of the lamps on the CPU blade.
CPU Blade
The CPU blade includes five lamps.
POWER lamp
STATUS lamp
LAN1 Link/Access lamp
LAN2 Link/Access lamp
ID lamp
1
2
ID
POWER Lamp
The POWER lamp lights green while the power of the CPU blade is on. The lamp lights amber
when the CPU blade is powered off but the power is supplied from the power supply unit. The lamp
is off if the power is not supplied to the system.
General Description 2-9
STATUS Lamp
The STATUS lamp stays lit in green when the CPU blade is in successful operation. When the
STATUS lamp is flashing in amber or red, it indicates that the system has failed.
In addition, you can view the detailed information on error message on virtual LCD when the
STATUS lamp is flashing in amber or red.
You can use the virtual LCD through the Web browser of EXPRESSSCOPE engine (BMC) or NEC
ESMPRO Manager.
The following table lists indications of the STATUS lamp, descriptions, and actions to take.
If an error occurs, contact your service representative.
NOTE: If the CPU blade has the NEC ESMPRO installed, you can
view the System Event Log (SEL) to identify the cause of a trouble.
STATUS lamp indications
STATUS lamp
StatusColor
OnGreenThe CPU blade is operating
Off–
OnRedBMC is being initialized.
FlashRed
FlashAmber
DescriptionAction
normally.
The power is turned off.
See the table "Virtual LCD indications when STATUS lamp is flashing in
red" described later.
See the table "Virtual LCD indications when STATUS lamp is flashing in
amber" described later.
NOTE: If the CPU blade is powered off while the STATUS lamp is
flashing in amber or red, the indication of the STATUS lamp is retained
except for certain factors. When the CPU blade is powered on, the
STATUS lamp goes on green (normal status).
–
Turn on the power.
1. Wait until the lamp goes off.
2. If the lamp still goes on, check
installation of the CPU blade.
2-10 General Description
Virtual LCD indications when STATUS lamp is flashing in red
On-screen messageDescriptionAction
Proc 1 IERRAn error was detected in CPU#1.
Proc 2 IERRAn error was detected in CPU#2.
WDT TimeoutWatchdog timer timeout error
occurred.
WDT Power DownForcedly powered off due to
watchdog timer timeout error.
SMI TimeoutA timeout error occurred while the
system management interrupt
process is in progress.
ErrPause in POST
DUMP Request !Under memory dump request
CPU1_DIMM U-Err
CPU2_DIMM U-Err
Proc MissingNo CPU is installed in slot CPU#1.
Proc1 Config ErrThe CPU installed in the CPU#1 slot
Proc2 Config ErrThe CPU installed in the CPU#2 slot
MEZ1 Power FaultAn error was detected in power
MEZ2 Power FaultAn error was detected in power
IOH Thermal Trip
Proc1ThermalTripForced power-off occurred due to a
Proc2ThermalTripForced power-off occurred due to a
Proc1 Therm % 09A high temperature error was
Proc2 Therm % 09A high temperature error was
CPUx_DIMMyTemp09A high temperature error was
AmbientTempAlm09A high temperature error was
The system is waiting for key entry
due to serious POST error.
An uncorrectable memory error was
detected on CPU1_DIMM.
An uncorrectable memory error was
detected on CPU2_DIMM.
is unsupported or its combination is
illegal.
is unsupported or its combination is
illegal.
circuit of mezzanine card installed in
Type 1 slot of CPU blade.
circuit of mezzanine card installed in
Type 2 slot of CPU blade.
Forced power-off occurred due to a
thermal error in chipset on CPU
blade.
thermal error in CPU#1.
thermal error in CPU#2.
detected in CPU #1.
detected in CPU #2.
detected in DIMM. x denotes CPU
number, and y denotes DIMM slot
number.
detected in CPU blade.
Turn of the power once and then
on again.
If an error message appears on
POST screen, take note of the
message, and contact your service
representative.
If no error message appears,
check the IPMI information by
using the Off-line Maintenance
Utility.
Check the error message on
POST screen, take note of it, and
contact your service
representative.
Wait until dump collection
completes.
Check installation status DIMM.
If the same error persists, contact
your service representative.
Check installation status of CPU.
If the same error persists, contact
your service representative.
Check installation status of
mezzanine card.
If the same error persists, contact
your service representative.
Check installation status of the
heat sink on the CPU blade.
Check if fans in Blade Enclosure
work normally.
Refer to the User’s Guide of the
Blade Enclosure to make sure that
the sufficient number of fans are
installed in correct locations.
Check if the fans and CPU blades
are installed in correct locations.
Check if the ambient temperature
of installation location satisfies the
operation guarantee condition.
If the same error persists, contact
your service representative.
On-screen messageDescriptionAction
AmbientTempAlm02
P1 VCCP Alm XX
P1 VTT Alm XX
P1 VDDQ Alm XX
P1 DDR_VTT AlmXX
P2 VCCP Alm XX
P2 VTT Alm XX
P2 VDDQ Alm XX
P2 DDR_VTT AlmXX
BB +1.1v Alm XX
BB +1.5v Alm XX
BB +1.8v Alm XX
BB +3.3v Alm XX
BB +5v Alm XX
BB +0.9vs Alm XX
BB +1.1vs Alm XX
BB +1.8vs Alm XX
BB +3.3vs Alm XX
BB +5vs Alm XX
BB +12vs Alm XX
Battery Alm XX
A low temperature error was
detected in CPU blade.
A voltage alarm was detected.
XX=09: Upper limit alarm
XX=02: Lower limit alarm
Check if the ambient temperature
of installation location satisfies the
operation guarantee condition.
If the same error persists, contact
your service representative.
Contact your service
representative.
General Description 2-11
Virtual LCD indications when STATUS lamp is flashing in amber
On-screen messageDescriptionAction
Mem Reconfigured
Mem Err Disable
CPU ReconfiguredThe failing CPU is forcedly used.Check installation status of CPU.
E-Keying ErrorIn the Blade Enclosure,
The failing memory is forcedly
used, or the memory is degraded.
Correctable memory error
frequently occurs.
combination of installation
locations of CPU blade,
mezzanine card, and switch
module is not correct. Thus, an
unconformity of interface signal
was detected and the CPU blade
failed to power on.
Check installation status of DIMM.
If the same error persists, contact your
service representative.
If the same error persists, contact your
service representative.
Refer to the User's Guide of Blade
Enclosure for correct installation
locations.
If the same error persists, contact your
service representative.
2-12 General Description
On-screen messageDescriptionAction
Location Error
Cooling ErrorIn the Blade Enclosure, the
Proc1 Therm % 07A high temperature warning was
Proc2 Therm % 07A high temperature warning was
CPUx_DIMMyTemp07 A high temperature warning was
AmbientTempAlm07A high temperature warning was
AmbientTempAlm00A low temperature warning was
P1 VCCP Alm XX
P1 VTT Alm XX
P1 VDDQ Alm XX
P1 DDR_VTT AlmXX
P2 VCCP Alm XX
P2 VTT Alm XX
P2 VDDQ Alm XX
P2 DDR_VTT AlmXX
BB +1.1v Alm XX
BB +1.5v Alm XX
BB +1.8v Alm XX
BB +3.3v Alm XX
BB +5v Alm XX
BB +0.9vs Alm XX
BB +1.1vs Alm XX
BB +1.8vs Alm XX
BB +3.3vs Alm XX
BB +5vs Alm XX
BB +12vs Alm XX
Battery Alm XX
In the Blade Enclosure, the
installation location of CPU blade
is incorrect, or the installation
locations of the fan and CPU
blade are incorrect. Thus, the
CPU blade failed to power on.
number of fans installed is
insufficient or the installed fan is
faulty. Thus, the CPU blade failed
to power on due to insufficient
cooling power.
detected in CPU #1.
detected in CPU #2.
detected in DIMM.
x, y: Indicates location of DIMM
slot.
detected in CPU blade.
detected in CPU blade.
A voltage warning was detected
on CPU blade.
XX=07: Upper limit warning
XX=00: Lower limit warning
Refer to the User's Guide of Blade
Enclosure to check if the CPU blade is
installed in correct location.
Check the installation locations of the fan
and CPU blade.
If the same error persists, contact your
service representative.
Check if the heat sink is installed
correctly on CPU blade.
Check if fans in Blade Enclosure work
normally.
Refer to the User’s Guide of the Blade
Enclosure to make sure that the
sufficient number of fans are installed in
correct locations.
Check if the fans and CPU blades are
installed in correct locations.
Check if the ambient temperature of
installation location satisfies the
operation guarantee condition.
If the same error persists, contact your
service representative.
Check if the ambient temperature of
installation location satisfies the
operation guarantee condition.
If the same error persists, contact your
service representative.
Contact your service representative.
General Description 2-13
LAN (1 - 2) Link/Access Lamps
The lamp goes on when LAN port is connected to the network. The lamp blinks when data is being
transmitted. When the CPU blade is powered on and the LAN cable is connected, the lamp on LAN
port for which the link is being established goes on. The connection of LAN port is physically
controlled by the EM card and the switch module installed in the Blade Enclosure.
To check connection status of LAN port, refer to the User's Guide of the EM card and the switch
module installed in the Blade Enclosure.
ID Lamp
Pressing the ID switch brings the lamp to light, and pressing again brings the lamp to go off. The ID
lamp is intended to identify a specific CPU blade in the system in which more than one CPU blade
is installed. Making this lamp being lit can help the maintenance work to identify the faulty device.
If you press the ID switch, the lamp goes on. When the recognize command is received from
management software such as NEC ESMPRO Manager, the lamp blinks.
You may use the remote control feature of EXPRESSSCOPE Engine 2 (BMC) to perform the same
operation as using the ID switch on the server.
2-14 General Description
USING YOUR SERVER
This section describes the basic operation of the blade server.
Power-on of Blade Server
There are the following two ways to turn on the power of the CPU blade. Turn on the power of the
CPU blade in any of the two ways after turning on the powers of the display unit and peripherals
connected to the CPU blade.
IMPORTANT: Perform the power-on operation of the CPU blade by
either the use of the POWER switch or the remote power-on after the
period of 30 seconds or longer has passed from the supply of AC power
to every power unit. The power-on operation within the period of 30
seconds from the supply of AC power to every power unit may not turn
on the power of the CPU blade. If so, turn on the power of the CPU
blade by using the POWER switch after making sure that the AC power
is supplied to every power unit.
NOTES:
If a power cord on the Blade Enclosure is connected to a power
controller including an uninterruptible power supply (UPS), make
sure that the power of the power controller is turned on.
When the power is supplied to the server, the initial diagnosis is
executed for about 30 seconds. In this period, the POWER switch is
disabled. Power on the server about 30 seconds immediately after
you installed the CPU blade or turned on the server.
General Description 2-15
Power ON from CPU Blade
Press the POWER switch on the panel of the CPU blade (the POWER lamp on the CPU blade goes
on green).
POWER lamp
POWER switch
1
2
ID
Power ON from Network Serial Port
Depending on the BIOS setting of the CPU blade, the power of the CPU blade may be automatically
turned on by a proper packet received from the network or via the modem connected to the serial
port.
This power-on procedure can be specified by setting [Wake On Events] of [System Hardware] in the
BIOS SETUP Utility.
Power ON from Remote Console
The power of the CPU blade can be turned on by using remote control feature of EXPRESSSCOPE
Engine 2 (BMC).
Operation after Power ON
If the CPU blade is connected with a display unit, the NEC logo appears on the screen of the display
unit after a while from the power-on.
While the NEC logo appears, the CPU blade runs the self-diagnosis program (POST) to diagnose
the CPU blade itself. See "POST" described later for details. At the completion of POST, OS is
booted.
NOTE: If a fault is found during POST, it is interrupted and the error
message notifying the fault appears. See Chapter 8.
2-16 General Description
Power-off of Blade Server
There are the following three ways to turn off the power of the CPU blade.
1. Power-off by OS shutdown
2. Power-off from CPU Blade
Press the POWER switch on the panel of the CPU blade
3. Power-off from Remote Console
The power of the CPU blade can be turned off by using "OS Shutdown" in remote control
feature of EXPRESSSCOPE Engine 2 (BMC).
The POWER lamp on the CPU blade of which power was turned off goes on amber.
NOTE: To power-off from CPU blade or remote console, the OS must
be set so that it starts shutdown process when the POWER switch on
the CPU blade is pressed.
POST
POST (Power On Self-Test) is the self-diagnostic program stored in the CPU blade.
When you power on the CPU blade, the system automatically runs POST to check the mother board,
ECC memory module, CPU module, keyboard, and mouse. POST also displays messages of the
BIOS SETUP utility, such as the start-up message, while in progress.
With the factory setup of the CPU blade, the NEC logo appears on the display unit (if connected)
while POST is in progress. To display the POST check results, press Esc.
NOTE: You can set the POST check results to appear on the display
unit without pressing Esc. To do so, select "Enabled" for "Boot-time
Diag Screen" under the Advanced menu of the BIOS SETUP utility.
See Chapter 4 for details.
You don't always need to check the POST check results. Check messages that POST displays when:
you use the blade server for the first time.
the server appears to fail.
an error message appears on the display unit.
General Description 2-17
POST Execution Flow
The following describes the progress of POST in the chronological order.
IMPORTANT:
Do not make unnecessary key entries or perform mouse operations
while POST is in progress.
Some system configurations may display the message "Press Any
Key" to prompt a key entry. This message is driven by BIOS of an
installed optional board. Make sure to read the manual that comes
with the optional board before any key entry.
Powering on the server, after you installed or removed an optional
mezzanine card, may display the message that indicates incorrect
board configuration and suspend POST.
In such a case, press F1 to continue POST. Board configuration can
be made using the utility described later.
1. After a few seconds from power-on, POST starts checking the memory. The count
message of the basic and expansion memory appears on the screen of the display unit (if
connected). The memory check may takes a few minutes to complete depending on the
memory size of the CPU blade. Also, it may take approximately one minute for the screen
display to appear after rebooting the CPU blade.
2. Some messages appear upon completion of the memory check. These messages appear to
indicate that the system has detected the CPU and other devices installed.
3. After a few seconds, POST displays the following message prompting you to launch the
BIOS setup utility, SETUP, stored in the system memory of the CPU blade. This message
appears at bottom left on the screen.
Press <F2> to enter SETUP
Launch the BIOS SETUP utility when you need to change the settings to meet the
requirements for the CPU blade. As long as the above message is not displayed with an
error message, you don't have to launch the utility. (Ignore the message. POST will
automatically proceed.)
To launch the SETUP utility, press F2 while the above message is displayed. See Chapter
4 for setup and parameters.
The CPU blade automatically restarts POST all over again when you exit the SETUP
utility.
4. If the server has an optional board installed, POST displays the board information on the
screen.
Refer to the manual supplied with the board for details.
POST will automatically proceed a few seconds later.
2-18 General Description
5. If you have set the password using the BIOS SETUP utility, the password entry screen
appears upon successful completion of POST.
Up to three password entries will be accepted. Three incorrect password entries disable
the system to boot. In such a case, turn off the power and wait about 30 seconds before
turning on to boot the CPU blade.
IMPORTANT: Do not set a password before installing an OS.
6. The OS starts when POST completes.
POST Error Messages
When POST detects an error, it displays an error message on the screen. See Chapter 8 for POST
error codes.
IMPORTANT: Take a note on the messages displayed before
consulting with your service representative. Alarm messages are useful
information for maintenance.
General Description 2-19
Device Identification
To identify the device to be maintained among more than one device, ID lamp is used.
The ID lamp is located on the CPU blade installed in the Blade Enclosure.
The ID lamp allows you to identify the device subject to maintenance among more than one CPU
blade installed in the Blade Enclosure.
The ID lamp on CPU blade can also be made blink blue by proper software commands from the
management PC on the network. In addition, pressing the ID switch on the CPU blade brings the ID
lamp to light.
You may use the remote control feature of EXPRESSSCOPE Engine 2 (BMC) to perform the same
operation as using the ID switch on the CPU blade.
1
ID switch
ID lamp
2
ID
2-20 General Description
(This page is intentionally left blank.)
Chapter 3
Setting Up Your Server
This chapter describes how to set up the server appropriate for your system, on a step-by-step basis.
3-2 Setting Up Your Server
BEFORE INSTALLING CPU BLADE
Be sure to check the MAC addresses before installing a CPU blade in the Blade Enclosure.
Check of MAC Address
A MAC address indicates the address specific for the network. It is expressed by 12-digit
alphanumeric starting with "003013". A CPU blade has two MAC addresses. Check the MAC
addresses before installing a CPU blade in the Blade Enclosure.
A MAC address is indicated in the area as shown in the figure below.
Label indicating
MAC address
The address of LAN port depends on the numeral and alphabet of the last digit of MAC address.
When the numeral/alphabet of the last digit is even number, A, C, or E:
The MAC address for LAN port 1 is as described on the label.
The MAC address for LAN port 2 can be obtained by adding 1 to the described MAC
address.
When the numeral/alphabet of the last digit is odd number, B, D, or F:
The MAC address for LAN port 1 can be obtained by adding 1 to the described MAC
address.
The MAC address for LAN port 2 can be obtained by adding 2 to the described MAC
address.
The MAC addresses can be checked from the proper Windows or Linux command.
Windows
Enter "ipconfig /all" for the MS-DOS prompt or from [Run] in the Start menu to see the
indicated physical address part.
Linux
Enter "ifconfig" for the prompt to see the indicated "Hwaddr".
You may use the remote control feature of EXPRESSSCOPE Engine 2 (BMC) to check the MAC
address.
Installing DIMM
If your CPU blade is not equipped with memory device, install DIMMs according to Chapter 9.
Setting Up Your Server 3-3
INSTALLING THE CPU BLADE
Install the CPU blade in the dedicated Blade Enclosure. Refer to the User's Guide of Blade
Enclosure for how to install the CPU blade.
IMPORTANT: The CPU blade is extremely sensitive to static
electricity. Make sure to touch the metal frame of the CPU blade to
discharge static electricity from your body before handling the CPU
blade. Do not touch the pins, leads, or circuitry and place the CPU
blade directly on the desk. For static notes, see "Anti-static Measures"
in Chapter 9.
3-4 Setting Up Your Server
MAKING CONNECTIONS
Connect peripheral devices to the CPU blade.
IMPORTANT:
Contact the maintenance engineer in your service representative if
you have any requests on the system configuration including the
connection to the uninterruptible power supply system or auto
power controller and the time schedule operation.
If you are installing the CPU blade in the Blade Enclosure
(SIGMABLADE), follow instructions described in the User's Guide
of the Blade Enclosure.
Observe the following instructions to use the server safely. Failure to follow
these instructions may result in death or serious personal injury. See pages 1-2
to 1-6 for details.
■ Do not hold the power plug with a wet hand.
■ Do not connect earth lines to any gas tubes.
WARNING
CAUTION
Observe the following instructions to use the server safely. Failure to follow
these instructions may cause a fire, personal injury, or property damage. See
pages 1-2 to 1-6 for details.
■ Do not plug the power cord in to an improper power source.
■ Do not connect the power cord to an outlet that has an illegal number of
connections.
■ Insert the power plug into the outlet as far as it goes.
■ Use the authorized power cord only.
■ Do not connect or disconnect any interface cable with the power cord of the
server plugged to a power source.
■Do not use any unauthorized interface cable.
Setting Up Your Server 3-5
In the ordinary operation, any cables may not be connected to a CPU blade. Proper cable(s) should
be connected to the USB, serial, and/or VGA ports on the CPU blade in the following cases:
Installing OS (when the CPU blade is installed in the Blade Enclosure (SIGMABLADE-
H))
Maintenance
Updating BIOS and firmware
The K410-150(00) SUV cable is a standard accessory for the Blade Enclosure (SIGMABLADE).
The K410-150(00) SUV cable has the USB, serial interface, and monitor connection connectors at
the other ends. Connect a proper device at each of the ends.
To serial interface device
To monitor
To USB devices
To CPU blade
IMPORTANT:
To connect a peripheral or interface cable provided by a vendor
other than NEC (or third party) to the CPU blade, make sure that the
device is available for the CPU blade. Some third party devices are
not available for the CPU blade.
The serial port connector cannot be directly connected with the
leased line.
Do not connect/disconnect the SUV cable or add/remove the USB
device until the operating system starts running.
To connect/disconnect the SUV cable or add/remove the USB
device after OS startup, follow restrictions of operating system.
If the device having serial interface is connected, first power off the
CPU blade and destination device, and remove the power cord from
the destination device before connecting/disconnecting SUV cable
or serial cable. Failure to follow it may cause the devices to be
defected due to the potential difference between them.
If the CPU blade is installed in the Blade Enclosure
(SIGMABLADE-H) and you are going to install an OS in it, use the
SUV cable. See the next page for connection.
3-6 Setting Up Your Server
USB Connection by K410-150(00) SUV Cable
Connect the floppy disk drive, DVD-ROM drive, keyboard, and mouse according to the figure
shown below.
Display unit
1
2
ID
USB
CPU blade
* Use the USB hub and external DVD-ROM
drive supported by this CPU blade.
USB
Self-powered
USB hub *
External floppy disk drive
External DVD-ROM drive *
Mouse
Keyboard
Network
The CPU blade is connected with network via the Blade Enclosure. Refer to the User's Guide of the
Blade Enclosure for details.
Chapter 4
Configuring Your Server
This chapter describes Basic Input Output System (BIOS) configuration.
When you install the blade server for the first time or install/remove optional devices, thoroughly
read this chapter for better understanding and correct setups.
SYSTEM BIOS ~ SETUP ~
The SETUP utility is provided to make basic hardware configuration for the CPU blade. This utility
is pre-installed in the flash memory of the CPU blade and ready to run.
The CPU blade is configured with the correct parameters using the SETUP utility and shipped in the
best conditions. Thus, you don't need to use the SETUP utility in most cases. However, you might
wish to use the SETUP utility in the cases described below.
IMPORTANT:
The SETUP utility is intended for system administrator use only.
The SETUP utility allows you to set a password. The CPU blade is
provided with two levels of password: Supervisor and User. With
the Supervisor password, you can view and change all system
parameters of the SETUP utility. With the User password, system
parameters available for viewing and changing are limited.
Do not set any password before installing the OS.
The CPU blade contains the latest version of the SETUP utility.
Dialog boxes appear on your SETUP utility, thus, may differ from
descriptions in this manual. If you find anything unclear, see the
online help or ask your sales representative.
4-2 Configuring Your Server
Starting SETUP Utility
Powering on the CPU blade starts POST (Power On Self-Test) and displays its check results. If the
NEC logo is displayed, press Esc.
After a while, the following message appears at bottom left on the screen.
Press <F2> to enter SETUP
Press F2 to start the SETUP utility and display its Main menu.
If you have previously set a password with the SETUP utility, the password entry screen appears.
Enter the password.
Enter password:[ ]
Up to three password entries will be accepted. If you fail to enter the password correctly for three
consecutive times, the CPU blade halts. (You can no longer proceed.) Power off the CPU Blade.
NOTE: The CPU blade is provided with two levels of password:
Supervisor and User. With the Supervisor password, you can view and
change all system parameters. With the User password, system
parameters available for viewing and changing are limited.
Configuring Your Server 4-3
Description on On-Screen Items and Key Usage
Use the following keyboard keys to work with the SETUP utility. (Key functions are also listed at
the bottom of the screen.)
Indicates
there are
submenus.
Setup item
menu
Indicates the current menu.
Online help
window
Explanation of key functions
Cursor (↑, ↓):
Selects an item on the screen. The highlighted item is currently
Parameter (high-lights upon selection) menu
selected.
Cursor (←, →):
Selects the Main, Advanced, Security, Server, Boot, or Exit menu.
– and +:Changes the value (parameter) of the selected item. When a
submenu option (an option preceded by "
³") is selected, these
keys are disabled.
Enter:Press Enter to select (determine) parameters.
Esc:
Displays the previous screen.
F1:Press F1 when you need help on SETUP operations. The help
screen for SETUP operations appears. Press Esc to return to the
previous screen.
F9:
Sets the parameter of the currently displayed item back to the
factory set parameter.
F10:
Save and exit the SETUP utility.
4-4 Configuring Your Server
Menu and Parameter Descriptions
The SETUP utility has the following six major menus:
Main
Advanced
Security
Server
Boot
Exit
To set minute functions, select a submenu from the above menus. The following describes available
functions and parameters, as well as the factory-set, for each menu.
Configuring Your Server 4-5
Main
OptionParameterDescriptionYour Setting
System TimeHH:MM:SSSet the system time.
System DateMM/DD/YYYYSet the system date.
Processor SettingsSelect submenuShows the processor settings
submenu.
[ ]: Factory-set
IMPORTANT: Check and adjust the system clock before the
operation if any of the following conditions is applicable.
After carriage of device
After storage of device
After the device is entered into the pause state under the
10°C - 35°C, humidity: 20% - 80%)
Check the system clock at the rough rate of once per month. When the
system clock is installed in a system requiring high time precision, it is
recommended to use a time server (NTP server).
If the system clock is remarkably delayed or advanced as the passage of
time in spite of adjustment, contact your service representative for
maintenance.
4-6 Configuring Your Server
Processor Settings
OptionParameterDescriptionYour Setting
Processor Speed Settingnnn GHzDisplays clock speed for the
processor. (View only)
Processor 1 CPUIDNumeral
Disabled
Not Installed
Error
Processor 1 L2 Cachennn KBDisplays L2 cache size for
Processor 1 L3 Cachennn KBDisplays L3 cache size for
Processor 2 CPUIDNumeral
Disabled
Not Installed
Error
Processor 2 L2 Cachennn KBDisplays L2 cache size for
Processor 2 L3 Cachennn KBDisplays L3 cache size for
Displays CPU ID for processor, if
present.
"Disabled" indicates that the
processor is defected.
"Not Installed" indicates that no
processor is installed.
"Error" indicates that the processor
is forcedly booted. (View only)
processor.
processor.
Displays CPU ID for processor, if
present.
"Disabled" indicates that the
processor is defected.
"Not Installed" indicates that no
processor is installed.
"Error" indicates that the processor
is forcedly booted. (View only)
processor.
processor.
Specifies the number of valid cores
in the processor.
TBD
Displayed only when the CPU
supports Execute Disable Bit.
Fixed to "Disabled" if the processor
does not support this feature.
Enables or disables the C1
Enhanced Mode.
Enables or disables the Intel(R)
virtualization technology.
Enables or disables the hardware
prefetcher.
Enables or disables the optimization
of an access from memory to cache.
[ ]: Factory-set
NOTE: Turbo Boost Technology is enabled or disabled linking with
setting of Intel SpeedStep(R) Technology, if the processor supports this
feature.
(Example) If Intel SpeedStep(R) Technology is disabled, Turbo Boost
Advanced Chipset Control–Displays Advanced Chipset Control
submenu.
Boot-time Diagnostic
Screen
Reset Configuration Data[No]
NumLockOn
Memory/Processor Error[Boot]
[Disabled]
Enabled
Yes
[Off]
Halt
When disabled, the BIOS will display
the NEC logo during POST. Press
Esc to switch to the POST execution
screen.
Select "Yes" if you want to clear the
system configuration data during the
next boot. Automatically reset to
"No" in the next boot.
Sets power on Numlock state.
If "Halt" is selected, the boot is
stopped when POST error occurs.
[ ]: Factory-set
IMPORTANT: Be sure to take a note of boot priority before selecting
"Yes" for [Reset Configuration Data], because the information on boot
device will be cleared. Select [Exit Saving Changes] to reboot the
system, run BIOS SETUP utility, and provide settings for boot device
order again.
4-8 Configuring Your Server
Memory Configuration
OptionParameterDescriptionYour Setting
Installed memorynnn MBIndicates the total capacity of the basic
memory. (View only)
Available under
4GB
CPU1_DIMM1 CPU1_DIMM6
Status
nnnnnnn MBIndicates the capacity of memory
available in the area under 4GB. (View
only)
Normal
Disabled
Not installed
Error
Indicates the current memory status
installed in CPU1_DIMM1 to
CPU1_DIMM6.
"Normal" indicates the normal status,
"Disabled" indicates a memory error, "Not
installed" indicates no DIMM installed, and
"Error" indicates the system is forcibly
started with memory error. (View only).
CPU2_DIMM1 CPU2_DIMM6
Status
Memory Retest[No]
Extended RAM
Step
Memory RAS
Mode
NUMA
configuration
Normal
Disabled
Not installed
Error
Yes
1MB
1KB
Every location
[Disabled]
[Independent]
Mirror
Lock Step
[Disabled]
Enabled
Indicates the current memory status
installed in CPU2_DIMM1 to
CPU2_DIMM6.
"Normal" indicates the normal status,
"Disabled" indicates a memory error, "Not
installed" indicates no DIMM installed, and
"Error" indicates the system is forcibly
started with memory error. (View only).
Causes BIOS to retest all memory on the
next boot.
"1MB" indicates that the memory test is
done in the unit of 1MB. "1KB" indicates
that the memory test is done in the unit of
1KB. "Every location" tests every memory
location. "Disabled" indicates that only
memory initialization is done.
Only pressing Space is acceptable to
suspend the test during the memory test.
Specifies the memory RAS mode. See
"DIMM" in Chapter 9 for details.
Disables or enables Non-Uniform Memory
Access feature.
[ ]: Factory-set
Configuring Your Server 4-9
PCI Configuration
OptionParameterDescriptionYour Setting
Mezzanine Slot
#1-2 Option ROM
Scan
PXE/iSCSI Select[PXE]
Enabled
[Disabled]
iSCSI
Indicates whether the expansion of
BIOS of mezzanine card to be
installed is enabled or disabled.
Specify PXE or iSCSI to boot the
mezzanine card to be installed.
[ ]: Factory-set
IMPORTANT: An option [PXE/iSCSI Select] is displayed only when
the mezzanine card that supports iSCSI standard is installed.
Onboard LAN
OptionParameterDescriptionYour Setting
LAN #1-2 Option
ROM Scan
PXE/iSCSI Select[PXE]
[Enabled]
Disabled
iSCSI
Indicates whether the expansion of
BIOS of on-board LAN controller is
enabled or disabled.
Specify PXE or iSCSI to boot the
onboard LAN controller.
[ ]: Factory-set
I/O Blade
OptionParameterDescriptionYour Setting
PCI Slot Option
ROM Scan
LAN #3-4 Option
ROM Scan
PXE/iSCSI Select[PXE]
Mezzanine Slot
#3-4 Option ROM
Scan
PXE/iSCSI Select[PXE]
[Enabled]
Disabled
[Enabled]
Disabled
iSCSI
Enabled
[Disabled]
iSCSI
Indicates whether the expansion of
BIOS of SCSI controller on I/O Blade
is enabled or disabled.
Indicates whether the expansion of
BIOS of LAN controller on I/O Blade is
enabled or disabled.
Specify PXE or iSCSI to boot the LAN
controller on I/O Blade.
Indicates whether the expansion of
BIOS of mezzanine card to be
installed on I/O Blade is enabled or
disabled.
Specify PXE or iSCSI to boot the
mezzanine card to be installed on I/O
Blade.
[ ]: Factory-set
4-10 Configuring Your Server
Peripheral Configuration
IMPORTANT: Note that the interrupt and/or base I/O address are not
overlapped with others. If the value set for the interrupt or base I/O
address is used in another resource, the yellow asterisk (*) appears.
Reset any item with the yellow asterisk properly.
OptionParameterDescriptionYour Setting
Serial Port BDisabled
[Enabled]
Base I/O
address
Interrupt[IRQ 3]
3F8h
[2F8h]
3E8h
2E8h
IRQ 4
Selects whether serial port B is enabled or
disabled.
Selects the base I/O address for serial port
A.
Selects the interrupt for a serial port A.
[ ]: Factory-set
Configuring Your Server 4-11
Advanced Chipset Control
OptionParameterDescriptionYour Setting
Multimedia TimerDisabled
[Enabled]
Intel(R) I/O ATDisabled
[Enabled]
Intel(R) VT-dDisabled
[Enabled]
Wake On
LAN/PME
Wake On Ring[Disabled]
Wake On RTC
Alarm
Disabled
[Enabled]
Enabled
[Disabled]
Enabled
Specify whether the system supports
the multimedia timer feature.
Enables or disables the Intel(R)
Acceleration technology.
Specify whether the Intel(R)
Virtualization Technology for Directed
I/O feature is enabled or disabled. This
item appears only when the processor
supports this feature.
Specify whether the remote power-on
feature through the device connected
to the standard network card or
expansion slot card is enabled or
disabled. To use Wake On LAN
feature, set the link speed and duplex
to [Auto].
Specify whether the remote power-on
function through a serial port is
enabled or disabled.
Specify whether the remote power-on
function by using RTC alarm feature is
enabled or disabled.
[ ]: Factory-set
IMPORTANT:
If the AC power is turned off while the Wake On Ring feature is
enabled, this feature is disabled at the next system boot after AC
power-on. You need to press the Power switch to boot the system. If
the AC power is turned off, Wake On Ring feature on power
management chip is disabled until the next DC power-on.
To use this feature on Windows Server 2003, see Chapter 8
"Problems with Windows Server 2003".
4-12 Configuring Your Server
Security
The Security menu appears if you move the cursor to the position of "Security."
Press Enter on "Set Supervisor Password" or "Set User Password," to display the following screen.
Enter the passwords on the dialog box. Passwords may have up to eight characters including
alphanumerics and symbols.
IMPORTANT:
User password can be set only when Supervisor password is already
set.
Set the passwords only after OS is installed.
See the table below for the items.
OptionParameterDescriptionYour Setting
Security Chip
Configuration
Supervisor
Password Is
User PasswordIsClear
Set Supervisor
Password
–Security Chip Configuration
submenu is displayed.
Clear
Set
Set
Up to eight
alphanumerics
Status only, user cannot modify.
Once set, this can be disabled by
setting it to a null string, or by
clearing password jumper on system
board (see Configuring Mother
Board Jumpers in this Chapter).
Status only, user cannot modify.
Once set, this can be disabled by
setting it to a null string, or by
clearing password jumper on system
board (see Configuring Mother
Board Jumpers in this Chapter).
When the <Enter> key is pressed,
the user is prompted for a password;
press ESC key to abort. Once set,
this can be disabled by setting it to a
null string, or by clearing password
jumper on system board (refer to
Configuring Mother Board Jumpers
in this
chapter).
Configuring Your Server 4-13
OptionParameterDescriptionYour Setting
Set User
Password
Password on
boot
Fixed disk boot
sector
Power Switch
Inhibit
Up to eight
alphanumerics
[Disabled]
Enabled
[Normal]
Write Protect
[Disabled]
Enabled
Supervisor password controls
access to the setup utility.
When Enter is pressed, the user is
prompted for a password; press Esc
to abort. Once set, this can be
disabled by setting it to a null string,
or by clearing password jumper on
system board (refer to Configuring
Mother Board Jumpers in this
chapter).
Disables or enables password entry
on boot.
Will write protect the boot sector of
the hard drive to prevent viruses
from corrupting the drive under DOS
if set to write protect.
Enables or disables the POWER
switch mask feature. If "Enabled" is
selected, power-off with the POWER
switch becomes unavailable after
OS boot-up. (Forced shut down
feature is always acceptable to the
server. Forced shut down is a
feature to shut down by pressing the
POWER switch for at least four
seconds.)
Changes TPM state.
(This option can be selected only
when the supervisor password is
set.)
[ ]: Factory-set
4-14 Configuring Your Server
T
T
T
T
T
IMPORTANT: If you select any parameter except for [No Change] to
change TPM State, a confirmation screen as shown below appears at
the end of POST after restarting the system. Select [Execute] on the
confirmation screen to determine the change you have made.
When [Enable & Activate] is selected:
Physical Presence operations
PM configuration change was requested to
State:Enable & Activate
Note:
his section will switch on the TPM
Reject
Execute
When [Deactivate & Disable] is selected:
Physical Presence operations
PM configuration change was requested to
State:Deactivate & Disable
Note:
his action will switch off the TPM
Doing so might prevent security applications
that rely on the TPM from functioning
as expected
Reject
Execute
When [Clear] is selected:
Physical Presence operations
PM configuration change was requested to
State:Clear
Clearing erases information stored on the TPM.
You will lose all created keys and access to
data encrypted by these keys.
Reject
Execute
WARNING!!!
WARNING!!!
Configuring Your Server 4-15
Server
OptionParameterDescriptionYour Setting
System
Management
Console
Redirection
BMC LAN
Configuration
Event Log
Configuration
Assert NMI on
PERR
Assert NMI on
SERR
FRB-2 PolicyDisable FRB2
Specify the address/interrupt of the
serial port to which a remote console
is connected.
Specify the baud rate used for the
interface with successive remote
consoles.
Specify the flow control method.
Specify the type of remote console.
Specify whether to continue console
redirection feature after completion of
POST.
Specify whether to enable or disable
resetting by Escape command (Esc R)
sent from the remote console.
If the server is connected with the
management PC that uses NEC
ESMPRO Manager, this option is
always enabled even if "Disabled" is
specified here.
[ ]: Factory-set
Configuring Your Server 4-19
BMC LAN Configuration Submenu
OptionParameterDescriptionYour Setting
IP Address[192.168.001.129]Specify an IP address for
management LAN.
Subnet Mask[255.255.255.000]Specify a subnet mask for
management LAN.
Default Gateway[192.168.001.254]Specify a default gateway for
management LAN.
DHCPDisabled
[Enabled]
Web Interface––
HTTPDisabled
[Enabled]
HTTP Port
Number
HTTPSDisabled
HTTPS Port
Number
Command Line
Interface
TelnetDisabled
Telnet Port
Number
SSH[Disabled]
SSH Port Number[22]Specify the TCP port number to be
Clear BMC
Configuration
[80]
[Enabled]
[443]Specify the TCP port number
––
[Enabled]
[23]Specify the TCP port number to be
Enabled
[Enter]
Set to [Enabled] to obtain an IP
address from DHCP server
automatically. If you intend to
specify an IP address manually,
set to [Disabled].
Set to [Enabled] to use HTTP
communication for Web interface.
Specify the TCP port number
which the management LAN uses
for HTTP communication.
Set to [Enabled] to use HTTPS
communication for Web interface.
which the management LAN uses
for HTTPS communication.
Set to [Enabled] to use Telnet
communication as a command line
interface.
used for Telnet communication.
Set to [Enabled] to use SSH
communication as a command line
interface.
used for SSH communication.
Press Enter and select "Yes" to
initialize the BMC configuration.
[ ]: Factory-set
4-20 Configuring Your Server
IMPORTANT: Notes on performing Clear BMC Configuration
Executing "Load Setup Defaults" in BIOS SETUP utility does not
restore the default value for settings related to management LAN of
BMC. To restore the default value, you need to execute Clear BMC
Configuration.
It takes about several tens seconds until initialization completes
after execution of Clear BMC Configuration.
If you are using NEC ESMPRO Agent Extension, settings for
remote management feature made in NEC ESMPRO Agent
Extension is also cleared by executing Clear BMC Configuration.
Before execution, be sure to make backup copy of setting
information for remote management feature by using NEC
ESMPRO Agent Extension or "System Management" in Tool menu
of NEC EXPRESSBUILDER.
NOTE: Executing [Save Custom Defaults/Load Custom Defaults] of
BIOS SETUP does not save the settings you have made in BMC LAN
Configuration menu.
Event Log Configuration Submenu
OptionParameterDescriptionYour Setting
System Event Log–System Event Log submenu is
displayed.
Auto Clear Event
Logs
Clear All Event
Logs
[Disabled]
Enabled
–
If set to "Enabled", logs are
automatically cleared when the error
log area is fulfilled.
Press Enter and select "Yes" to clear
the system event log.
[ ]: Factory-set
Configuring Your Server 4-21
Boot
The CPU blade searches for devices in the order set in this menu on booting. Finding the boot
software, the CPU blade starts the software.
The priority of the boot devices can be changed by using the ↑, ↓, +, and - keys. Move the cursor to
the desired device with the ↑ or ↓ key and change the priority with the + or - key.
The boot device priority is factory-set in the following order.
– USB CDROM (optical drive)
– USB FDC (removable device)
– IBA GE Slot 0100 v1322 (LAN1)
– Hard Drive
– USB Hard Drive
– IBA GE Slot 0101 v1322 (LAN2)
4-22 Configuring Your Server
Exit
The options on the menu are described below.
IMPORTANT: The values of SETUP at the shipment may be
different from their default values depending on the model of the CPU
blade. It is necessary to set the values meeting the environment in
which the CPU blade is used referring to the models.
Exit Saving Changes
Exit after writing all modified BIOS SETUP item values to CMOS.
Exit Discarding Changes
Exit leaving CMOS unmodified. User is prompted if any of the setup fields ware modified.
Load Setup Defaults
Load default values for all BIOS SETUP items.
Load Custom Defaults
Load custom defaults for BIOS SETUP options.
Save Custom Defaults
Saves the current values as custom defaults. The “Load Custom Defaults” menu appears on the
screen after saving the custom default values.
Discard Changes
Read the previous values of the all BIOS SETUP items from CMOS.
Save Changes
Write all BIOS SETUP item values to CMOS.
Chapter 5
Installing the Operating System with Express
Setup
This section describes information on using Express Setup to install and configure the following
operating systems to server.
Windows Server 2008 Standard 64-bit (x64) Edition / Windows Server 2008 Enterprise
64-bit (x64) Edition
Windows Server 2008 Standard 32-bit (x86) Edition / Windows Server 2008 Enterprise
32-bit (x86) Edition
Windows Server 2003 R2 Standard Edition / Windows Server 2003 R2 Enterprise Edition
To use the server with the other operating systems described in this section, contact your service
representative.
IMPORTANT: Before installing the operating system, adjust the
system date and time by using the BIOS setup utility "SETUP." See
Chapter 4 for detail.
5-2 Installing the Operating System with Express Setup
About Express Setup
"Express Setup" helps you to install the Windows Operating System. The setup automatically
configures the RAID System and installs the Operating System and some management software.
IMPORTANT: Executing the Express Setup erases all data on the
hard disk drive.
You can also use "Parameter File" at "Express Setup" in order to save or backup parameters for
installation.
If you want to set up the server as before, execute the Express Setup with the parameter file you
have saved before.
NOTES:
If you want to create a parameters file, have a blank floppy disk
(MS-DOS 1.44MB format) ready.
When using a floppy disk, a USB floppy disk drive is required.
If you want to use the drivers located on the "OEM-Disk for Mass
Storage Device" that ships with optional boards, a parameters file
is mandatory.
You can create a parameters file in advance using "Parameter File
Creator" included in NEC EXPRESSBUILDER.
Installing the Operating System with Express Setup 5-3
Windows Server 2008
This section explains how to install Windows Server 2008 by using the Express Setup.
NOTE: If you install Windows Server 2008 without using Express
Setup, see Appendix B.
Notes on Windows Installation
This section explains the notes on the Windows installation.
Confirm these notes before starting the Express Setup.
About the Windows Family
This computer supports the following Windows editions:
Windows Server 2008 Standard 64-bit (x64) Edition / Windows Server 2008 Enterprise
64-bit (x64) Edition (hereinafter, referred to as "Windows Server 2008")
Windows Server 2008 Standard 32-bit (x86) Edition / Windows Server 2008 Enterprise
32-bit (x86) Edition (hereinafter, referred to as "Windows Server 2008")
On installing other OS, contact sales dealer or the maintenance service representative.
NOTE: If you use iSCSI environment, "Server Core Installation" is
not supported.
In this case, select "Full Installation".
BIOS Settings
Confirm the BIOS settings described in Chapter 4 before installing Windows Server 2008.
Service Pack Which EXPRESSBUILDER Supports
The NEC EXPRESSBUILDER DVD attached to the server supports following combination of the
OS installation media and Service Pack.
Windows Server 2008
– OS installation media (No Service Pack)
5-4 Installing the Operating System with Express Setup
Supported Options by NEC EXPRESSBUILDER
The NEC EXPRESSBUILDER DVD attached to your system supports the following options for
installation.
NOTE: If you want to install the other boards by using a driver floppy
disk ("OEM-FD for Mass storage device"), except ones listed below,
see "Installing with the OEM-FD for Mass storage device" and
"Installing Optional Mass Storage Driver" of "Parameter File Creator"
in Chapter 6.
Options supporting installation of OS with Express Setup
The driver of option card mentioned above is stored in the NEC
EXPRESSBUILDER DVD.
If you use the board not mentioned above, the Express Setup will
fail. Refer to the instructions attached to the board.
About the Hardware Components
When you install the Windows Server 2008, Express Setup requires several preparations if this
computer uses the following hardware components.
Installing on the Mirrored Volume
When re-installing the OS to a hard disk drive which has been upgraded to Dynamic Disk, only the
simple dynamic volume is available for installation.
If you want to install the OS on a volume that is mirrored using Disk Management, invalidate the
mirroring and reset to the basic disk before the installation, and validate the mirroring again after the
installation.
You can create, invalidate, or delete the mirror volume by using Disk Management in Computer
Management.
Installing the Operating System with Express Setup 5-5
Connecting Hard Disk Drive
Do not connect the other hard disk drives except the drive that you want to create the Windows
system drive.
If you create multiple logical drives in your system, see "Re-installing the Operation System if
Multiple Logical Drives Exist" (Appendix B).
Re-installing to the hard disk drive which has been upgraded to Dynamic
Disk
You cannot re-install Windows Server 2008 with the current partition of the hard disk drive
upgraded to Dynamic Disk kept remained.
If you want to keep the current partition remained, see Appendix B to re-install the system.
Case of using RAID Controller
When you install Windows Server 2008 32bit (x86) Edition by Express Setup after RAID is newly
constructed, the following message may be displayed.
When the message is displayed, refer to following procedure and create RAID beforehand.
Creating RAID manually
For the detailed operation, refer to "RAID Configuration (Chapter 4)" in User's Guide that
comes with the Storage and I/O Blade AD106a.
Creating RAID using EXPRESSBUILDER
See "Creating new RAID using RAID Controller (Page 5-55 in this User's Guide)".
5-6 Installing the Operating System with Express Setup
About the System Partition Size
The system partition size can be calculated from the following formula.
When the system is Windows Server 2008 64-bit (x64) Edition:
Required partition size= size required to install OS + paging file size + dump
file size + application size
Size required to install OS= 11,600MB (Full Installation)
The above-mentioned paging file size is recommended for
collecting debug information (memory dump). The paging file
with initial size large enough to store the dump file in the boot
drive is required.
Correct debug information might not be able to be collected due to
virtual memory shortage when the paging file is insufficient, so set
an enough size of the paging file with the entire system.
Regardless of the size of the mounted memory, or the Write
debugging information (type of memory dump), the maximum size
of the dump file is 'The size of the mounted memory + 300MB'.
If you install any application program or the like, add necessary
space to the partition to install these programs.
Example:
The partition size required for a system with an installed memory size of 512 MB and a full
installation of the operating system:
The above-mentioned paging file size is recommended for
collecting debug information (memory dump). The paging file
with initial size large enough to store the dump file in the boot
drive is required.
Correct debug information might not be able to be collected due to
virtual memory shortage when the paging file is insufficient, so set
an enough size of the paging file with the entire system.
The maximum paging file size which can be set on one partition is
4095MB. If the above paging file size exceeds 4095MB, specify
4095MB for the paging file size.
The maximum dump file size for the system with more than 2GB
memory mounted is '2048MB + 300MB'.
If you install any application program or the like, add necessary
space to the partition to install these programs.
Example:
The partition size required for a system with an installed memory size of 512 MB and a full
installation of the operating system:
If the partition where the operating system is installed is smaller than that required to install the OS
and paging file, expand the partition size or utilize a larger disk. If your system does not have a
sufficient dump file size, divide the required file space into multiple disks by performing the steps
below:
1. Set the partition size to a size sufficient to install the OS and paging file.
2. See "Setting for Solving Problems" to write the debug information of the dump file on to
another disk.
If there is not enough disk space to write the debug information, add another disk for the dump file.
5-8 Installing the Operating System with Express Setup
A
Flow of Setup
Remove the Floppy Disk and CD/DVD-ROM
from the Drive
Loading parameters (Step 2)
Next
Select the operating system (Step 3)
Next
RAID configuration (Step 4)
Next
Windows Confirm Setting / Input
(Steps 5 to 10)
Next
Save parameters (Step 11)
Next
Start Express Setup (Step 12)
Perform
RAID Configuration
Create the OS partition / format
Copying Windows driver
↓
Copying Selected Application
Skip
Insert Windows CD-ROM
Install OS Automatically
gree Software License Agreement
Log on
The installation is completed.
: Process that needs to input or select
: Process that proceeds automatically
Installing the Operating System with Express Setup 5-9
Installing the Windows Server 2008
Express Setup proceeds the setup by selecting or inputting several parameters on the wizard. You
can also save the parameters to a floppy disk as a parameters file.
1. Turn the power of peripheral device on, and then turn on the server.
2. Insert the NEC EXPRESSBUILDER DVD into the optical disk drive of the server.
3. Press the RESET switch or press Ctrl, Alt, and Delete to reboot from the NEC
EXPRESSBUILDER. (You may also turn off and then on again to reboot the server.)
The system will boot from the DVD and NEC EXPRESSBUILDER starts.
Select "Os installation *** default ***" from the Boot selection menu.
(If you do not hit any key, "Os installation" is selected automatically.)
The Top menu will appear.
5-10 Installing the Operating System with Express Setup
4. Select [English] from the Select Language, click [OK].
5. Select [Perform the Express setup] from the Top Menu, click [Next].
Installing the Operating System with Express Setup 5-11
6. [Load parameters] steps are displayed.
[Do not load parameters]
(1) Select [Do not load parameters].
(2) Click [Next].
NOTE: If a floppy disk drive is not connected, select this item.
[Load parameters]
(1) Insert the floppy disk containing the parameters file.
(2) Select [Load parameters], enter the file path of the parameters file into the text box.
(3) Click [Next].
5-12 Installing the Operating System with Express Setup
7. Select the installing Operating System.
Select [Install the Windows (32bit editions)] from the menu, click [Next].
8. Enter the setting of a logical drive.
[Enter RAID settings] steps are displayed. Confirm the parameters, modify if necessary,
and then click [Next].
Installing the Operating System with Express Setup 5-13
NOTES:
You can use only the physical devices that have same model
number to configure logical drive.
If the process is not finished normally, the driver may not be stored
in the EXPRESSBUILDER. Refer to "Optional Board Supported
by NEC EXPRESSBUILDER" described earlier in this chapter.
When you use RAID Controller, if [Skip the logical drive creation]
is not selected at [Enter RAID settings] screen, refer to "RAID
Configuration (Chapter 4)" in User's Guide that comes with the
Storage and I/O Blade AD106a, or "Creating New RAID using
RAID Controller (Page 5-55 in this User's Guide)" to create RAID
beforehand.
9. Specify the installing medium and the Windows system partition.
[Specify medium / Partition] steps are displayed. Confirm the parameters, modify if
necessary, and then click [Next].
5-14 Installing the Operating System with Express Setup
IMPORTANT:
If you use iSCSI environment, "Server Core Installation" is not
supported.
In this case, select "Full Installation".
About partition size
– Specify the partition size larger than required minimum size for
OS installation.
– Do not specify larger partition size than the capacity of
connected hard disk drive.
– You can not specify a logical drive larger than 2,097,144MB at
RAID system.
If you select "Create a new partition" at "Windows system drive
settings", the contents of the hard disk will be all deleted.
If "Use existing partitions" is selected, EXPRESSBUILDER
installs the Operating System to the 1st partition (1st partition is
deleted). The data in the other partition is kept if the system has
two or more partitions. (See the figure below.)
First
Partition
Deleted
Second
Partition
Retained
Third
Partition
Retained
You can not re-install the system with the existing partition that is
upgraded to Dynamic Disk remained. Do not select "Use existing
partitions" at "Windows system drive settings".
Installing the Operating System with Express Setup 5-15
10. Enter the user information and client license mode.
[Enter basic parameters] steps are displayed. Confirm the parameters, modify if necessary,
and then click [Next].
IMPORTANT: Computer name and Administrator password that
satisfy the next condition, are required.
– More than 6 characters
– Contains characters from three of the following categories
(numbers, uppercase letters, lowercase letters, and signs).
5-16 Installing the Operating System with Express Setup
11. Enter the setting of the network protocol.
[Enter Network Protocol] steps are displayed. Confirm the parameters, modify if
necessary, and then click [Next].
12. Enter the domain or workgroup name to be used.
[Enter domain account] steps are displayed. Confirm the parameters, modify if necessary,
and then click [Next].
Installing the Operating System with Express Setup 5-17
13. Select the installing components.
[Select Windows components] steps are displayed. Confirm the parameters, modify if
necessary, and then click [Next].
<Full Installation>
<Server Core Installation>
5-18 Installing the Operating System with Express Setup
14. Select the installing applications.
[Select applications] steps are displayed. Confirm the parameters, modify if necessary, and
then click [Next].
15. Save the parameters.
[Save parameters] steps are displayed.
If you want to save the parameters , set the free formatted floppy disk.
Select [Save parameters], enter the file path of the parameters files into the text box and
click [Next].
If not, select [Do not save parameters].
Installing the Operating System with Express Setup 5-19
16. The Express Setup will start when you click [Perform] in [Start Express setup] step.
17. Copy optional Mass Storage Driver module.
If you install optional Mass Storage Driver, the message will be shown.
Insert CD-ROM or floppy disk attached to the Mass Storage Driver and proceed operation
according to the message.
18. Remove NEC EXPRESSBUILDER DVD from the optical disk drive according to the
message.
If you proceed the setup by using setup parameter file, remove the floppy disk from the
floppy disk drive.
19. Insert Windows Server 2008 DVD-ROM into the optical disk drive.
NOTE: Windows Server 2008 and selected applications will be
installed automatically and reboots several times.
5-20 Installing the Operating System with Express Setup
Setup your computer in advance so that it can recover from any trouble precisely and as soon as
possible when it should occur.
For more information, refer to Page 5-42.
5-24 Installing the Operating System with Express Setup
Windows Server 2003
This section explains how to install Microsoft® Windows Server® 2003 by using the Express
Setup.
NOTES:
Express Setup does not support the installation of Windows Server
x64 Editions. If you want to install it, see Appendix B.
If you install Windows Server 2003 without using Express Setup,
see Appendix B.
Notes on Windows Installation
This section explains the notes on the Windows installation.
Confirm these notes before starting the Express Setup.
About the Windows family
This computer supports the following Windows editions:
Microsoft® Windows Server® 2003 R2 Standard Edition / Microsoft® Windows Server®
2003 R2 Enterprise Edition (hereinafter, referred to as "Windows Server 2003")
NOTE: Express Setup does not support the installation of Windows
Server 2003 x64 Editions. If you want to install it, see Appendix B.
On installing other OS, contact sales dealer or the maintenance service representative.
BIOS Settings
Confirm the BIOS settings described in Chapter 4 before installing Windows Server 2003.
Installing the Operating System with Express Setup 5-25
Service Pack Which EXPRESSBUILDER Supports
The NEC EXPRESSBUILDER DVD attached to the server supports following combination of the
OS installation media and Service Pack.
Windows Server 2003 R2 x64 Edition
– OS installation media (with Service Pack 2)
– OS installation media (No Service Pack) + Service Pack 2
– OS installation media (No Service Pack)
Windows Server 2003 R2
– OS installation media (with Service Pack 2)
– OS installation media (No Service Pack) + Service Pack 2
– OS installation media (No Service Pack)
Supported Options by NEC EXPRESSBUILDER
The NEC EXPRESSBUILDER DVD attached to your system supports the following options for
installation.
NOTE: If you want to install the other boards by using a driver floppy
disk ("OEM-FD for Mass storage device"), except ones listed below,
see "Installing with the OEM-FD for Mass storage device" and
"Installing Optional Mass Storage Driver" of "Parameter File Creator"
in Chapter 6.
Options supporting installation of OS with Express Setup
The driver of option card mentioned above is stored in the NEC
EXPRESSBUILDER DVD.
If you use the board not mentioned above, the Express Setup will
fail. Refer to the instructions attached to the board.
5-26 Installing the Operating System with Express Setup
About the Hardware Components
When you install the Windows Server 2003, Express Setup requires several preparations if this
computer uses the following hardware components.
Installing on the Mirrored Volume
If you want to install the Windows Server 2003 on the volume that is mirrored using "Disk
Management", invalidate the mirroring and set back to the basic disk before the installation, and
validate the mirroring again after the installation.
You can create, invalidate or delete the mirror volume by using "Disk Management" in "Computer
Management".
Mounting MO Device
Do not mount an MO device on this computer during the Windows installation.
About Removable Media
Do not set removable media, such as DAT, into the device mounted on this computer during the
Windows installation.
Connecting Hard Disk Drive
Do not connect the other hard disk drives except the drive that you want to create the Windows
system drive.
If you create multiple logical drives in your system, see "Re-installing the Operation System if
Multiple Logical Drives Exist" (Appendix B).
Re-installing to the hard disk drive which has been upgraded to Dynamic Disk
You cannot re-install Windows Server 2003 with the current partition of the hard disk drive
upgraded to Dynamic Disk kept remained.
If you want to keep the current partition remained, see Appendix B to re-install the system.
Installing the Operating System with Express Setup 5-27
About the System Partition Size
The system partition size can be calculated from the following formula.
Size necessary to install the system + Paging File Size + Dump File Size
+ Application Size
Size necessary to install the system = 3500MB (Windows Server 2003 R2)
The above-mentioned paging file size is recommended for
collecting debug information (memory dump). The paging file
with initial size large enough to store the dump file in the boot
drive is required.
Correct debug information might not be able to be collected due to
virtual memory shortage when the paging file is insufficient, so set
an enough size of the paging file with the entire system.
The maximum paging file size which can be set on one partition is
4095MB. If the above paging file size exceeds 4095MB, specify
4095MB for the paging file size.
The maximum dump file size for the system with more than 2GB
memory mounted is '2048MB + 12MB'.
If you install any application program or the like, add necessary
space to the partition to install these programs.
For example, if the mounted memory size is 512MB, the partition size will be calculated by the
above formula as follows:
5-28 Installing the Operating System with Express Setup
Dividing into the partition of the recommended size into multiple disks as written below will solve
problem that it cannot be reserved in one disk.
1. Set the "Size required for installation + Paging file size".
2. See Chapter 5 and set that debugging information (equivalent to the dump file size) is to
be written to a separate disk.
(If the disk does not have enough free space to enable the dump file size to be written,
then after installing the system using the "Size required for installation + Paging file size",
install an additional new disk.)
Installing the Service Pack
When installing Windows Server 2003 R2, it is not necessary to install the Service Pack 1.
When installing Windows Server 2003 R2, do not apply Service Pack by Express Setup.
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.