1 [Set Temperature] Button
2 [TIMER MENU] Button 3 [Mode] Button
[MONITOR/SET] Button [BACK] Button
4 [TIMER ON/OFF] Button 5 [Louver] Button
[SET DAY] Button [OPERATION] Button
6 [Fan Speed] Button 7 [Vane Control] Button
8 [Ventilation] Button
[OPERATION] Button
9 [CHECK/CLEAR] Button 0 [TEST RUN] Button
A [FILTER] Button B [ON/OFF] Button
[ ] Button
C Position of built-in room temperature sensor D [Set Time] Button
•Never expose the remote controller to direct sunlight. Doing so can result in
the erroneous measurement of room temperature.
•Never place any obstacle around the lower right-hand section of the remote
controller. Doing so can result in the erroneous measurement of room tem-
perature.
ON/OFF
FILTER
CHECK
CLEAR
MENU
ON/OFF
TEST
TEMP.
CLOCK
OPERATION
BACK DAY
MONITOR/SET
1
2
3
4D5689C
0
A
B
7
Remote controller-Button Touche Commande à distance
GB F
1 Touche [Réglage de la température]
2 Touche [TIMER MENU] 3 Touche [Mode]
Touche [MONITOR/SET] Touche [BACK]
4 Touche [TIMER ON/OFF] 5 Touche [Louvre]
Touche [SET DAY] Touche [OPERATION]
6 Touche [Vitesse du ventilateur] 7 Touche [
Commande des ailettes
]
8 Touche [Ventilation]
Touche [OPERATION]
9 Touche [CHECK/CLEAR] 0 Touche [TEST RUN]
A Touche [FILTER] B Touche [ON/OFF]
Touche [ ]
C Position du capteur de température de la pièce intégré
D Touche de [réglage de l’heure]
Ne jamais laisser la commande à distance en plein soleil sinon les données de
température ambiante risquent d’être erronées.
Ne jamais placer d’obstacle devant la partie inférieure droite de la commande
à distance sinon la lecture des températures ne sera pas correcte.
I
DFEINLPGRRUTRGBGBGBGBGB
GB
D
FINL EPGRRUTR
33
A Heure réelle/heure de la minuterie
B Témoin de commande à distance centralisée
C Témoin de minuterie OFF
D Témoin de mode de minuterie
E
Affichage du mode de fonctionnement
: FROID, DESHU, AUTO, VENTILATION,
CHAUD
F Témoin de mode de fonctionnement G Température prédéfinie
H Témoin d’alimentation I Louvre
J Ventilation K Signe du filtre
L Position du capteur M Température de la pièce
N Réglage des ailettes O Vitesse du ventilateur
P Témoin de fonctionnement
Remote controller-Display Affichage Commande à distance
GB F
A Current time/Timer time
B Centralized control indicator
C Timer OFF indicator
D Timer mode indicator
E Operation mode display: COOL, DRY, AUTO, FAN, HEAT
F Function mode indicator G Preset temperature
H Power indicator I Louver
J Ventilation K Filter sign
L Sensor position M Room temperature
N Vane setting O Fan speed
P Operation lamp
ON/OFF
ERROR CODE
TIME
ON
OFF
Hr
AFTER
SUN MON TUE WED THU FRI SAT
TIMER
AFTER
ONLY 1Hr.
˚C˚F
WEEKLY
SIMPLE
AUTO OFF
FILTER
FUNCTION
˚C˚F
TEMP.
E
B
C
H
IN MGPJD
L
A
O
F
K
44
2
:
In case of bottom inlet
En cas d’entrée sur le dessous
1
:
In case of rear inlet
En cas d’entrée arrière
A: Filter
Filtre
: Air Flow
Flux d’air
A
1
A
2
[Fig.A]
5
I
DFEINLPGRRUTRGBGBGBGBGB
GB
1. Safety precautions
s Before operating the unit, make sure you read all the “Safety
precautions”.
s “Safety precautions” lists important points about safety.
Please be sure to follow them.
Symbols used in the text
Warning:
Describes precautions that should be observed to avoid the risk of injury or
death to the user.
Caution:
Describes precautions that should be observed to prevent damage to the unit.
Symbols used in the illustrations
: Indicates an action that must be avoided.
: Indicates that important instructions must be followed.
: Indicates a part which must be grounded.
: Indicates that caution should be taken with rotating parts. (This symbol is
displayed on the main unit label.) <Color: yellow>
:Beware of electric shock. (This symbol is displayed on the main unit label.)
<Color: yellow>
Warning:
Carefully read the labels affixed to the main unit.
1.1. Installation
s After you have read this manual, keep it and the Installation Manual in a
safe place for easy reference whenever a question arises. If the unit is
going to be operated by another person, make sure that this manual is
given to him or her.
Warning:
The unit should not be installed by the user. Ask the dealer or an author-
ized company to install the unit. If the unit is installed improperly, water
leakage, electric shock or fire may result.
Use only accessories authorized by Mitsubishi Electric and ask your
dealer or an authorized company to install them. If accessories are in-
stalled improperly, water leakage, electric shock or fire may result.
The Installation Manual details the suggested installation method. Any
structural alteration necessary for installation must comply with local
building code requirements.
•Never repair the unit or transfer it to another site by yourself. If repair is
performed improperly, water leakage, electric shock or fire may result. If
you need to have the unit repaired or moved, consult your dealer.
•Keep the electric parts away from water (washing water) etc.
It might result in electric shock, catching fire or smoke.
Note1:
When washing the Heat Exchanger and Drain Pan, ensure the Con-
trol Box, Motor and LEV remain dry, using a water proof covering.
Note2: Never drain the washing water for the Drain Pan and the Heat
Exchanger using the Drain Pump. Drain separately.
The appliance is not intended for use by young children or infirm per-
sons without supervision.
•Young children should be supervised to ensure that they do not play
with the appliance.
Do not use a leak detection additive.
1) Outdoor unit
Warning:
The outdoor unit must be installed on a stable, level surface, in a place
where there is no accumulation of snow, leaves or rubbish.
Do not stand on, or place any items on the unit. You may fall down or the
item may fall, causing injury.
Caution:
The outdoor unit should be installed in a location where air and noise emit-
ted by the unit will not disturb the neighbours.
2) Indoor unit
Warning:
The indoor unit should be securely installed. If the unit is loosely mounted, it
may fall, causing injury.
3) Remote controller
Warning:
The remote controller should be installed in such a way that children cannot
play with it.
4) Drain hose
Caution:
Make sure that the drain hose is installed so that drainage can go ahead
smoothly. Incorrect installation may result in water leakage, causing dam-
age to furniture.
5) Power line, fuse or circuit breaker
Warning:
Make sure that the unit is powered by a dedicated supply. Other appli-
ances connected to the same supply could cause an overload.
Make sure that there is a main power switch.
Be sure to adhere to the unit’s voltage and fuse or circuit breaker ratings.
Never use a piece of wire or a fuse with a higher rating than the one
specified.
6) Grounding
Caution:
The unit must be properly grounded. Never connect the grounding wire
to a gas pipe, water pipe, lightning conductor or telephone grounding
wire. If the unit is not grounded properly, electric shock may result.
Check frequently that the ground wire from the outdoor unit is properly
connected to both the unit’s ground terminal and the grounding electrode.
1.2. During operation
Caution:
Do not use any sharp object to push the buttons, as this may damage the
remote controller.
Do not twist or tug on the remote controller cord as this may damage the
remote controller and cause malfunction.
•Never remove the upper case of the remote controller. It is dangerous to
remove the upper case of the remote controller and touch the printed
circuit boards inside. Doing so can result in fire and failure.
•Never wipe the remote controller with benzene, thinner, chemical rags,
etc. Doing so can result in discoloration and failure. To remove heavy
stains, soak a cloth in neutral detergent mixed with water, wring it out
thoroughly, wipe the stains off, and wipe again with a dry cloth.
•Never block or cover the indoor or outdoor unit’s intakes or outlets. Tall
items of furniture underneath the indoor unit, or bulky items such as
large boxes placed close to the outdoor unit will reduce the unit’s effi-
ciency.
Warning:
Do not splash water over the unit and do not touch the unit with wet
hands. An electric shock may result.
Do not spray combustible gas close to the unit. Fire may result.
Do not place a gas heater or any other open-flame appliance where it will
be exposed to the air discharged from the unit. Incomplete combustion
may result.
Contents
1. Safety precautions ...................................................................................... 5
1.1. Installation ................................................................................. 5
1.2. During operation ........................................................................ 5
1.3. Disposing of the unit .................................................................. 6
2. Names and functions of various parts ........................................................ 6
3. How to operate ........................................................................................... 6
3.1. ON/OFF ..................................................................................... 6
3.2. Selecting operation .................................................................... 6
3.3. Room temperature adjustment .................................................. 7
3.4. Fan speed adjustment ............................................................... 7
3.5. Ventilation .................................................................................. 7
3.6. Others ........................................................................................ 7
4. The smart way to use ................................................................................. 7
5. Caring for the machine ............................................................................... 8
6. Troubleshooting ........................................................................................... 8
7. Installation, transferring works, and checking ............................................. 9
8. Specifications .............................................................................................. 9
6
DFEINLPGRRUTRGBGBGBGBGB
GB
Warning:
Do not remove the front panel or the fan guard from the outdoor unit
when it is running. You could be injured if you touch rotating, hot or high-
voltage parts.
•Never insert fingers, sticks etc. into the intakes or outlets, otherwise in-
jury may result, since the fan inside the unit rotates at high speed. Exer-
cise particular care when children are present.
If you detect odd smells, stop using the unit, turn off the power switch
and consult your dealer. Otherwise, a breakdown, electric shock or fire
may result.
When you notice exceptionally abnormal noise or vibration, stop opera-
tion, turn off the power switch, and contact your dealer.
Do not over-cool. The most suitable inside temperature is one that is
within 5 °C of the outside temperature.
Do not leave handicapped people or infants sitting or standing in the path
of the airflow from the air-conditioner. This could cause health problems.
Caution:
Do not direct the airflow at plants or caged pets.
•Ventilate the room frequently. If the unit is operated continuously in a
closed room for a long period of time, the air will become stale.
In case of failure
Warning:
•Never remodel the air conditioner. Consult your dealer for any repair or serv-
ice. Improper repair work can result in water leakage, electric shock, fire, etc.
If the remote controller displays an error indication, the air conditioner
does not run, or there is any abnormality, stop operation and contact
your dealer. Leaving the unit as it is under such conditions can result in
fire or failure.
If the power breaker is frequently activated, get in touch with your dealer.
Leaving it as it is can result in fire or failure.
If the refrigeration gas blows out or leaks, stop the operation of the air
conditioner, thoroughly ventilate the room, and contact your dealer. Leav-
ing the unit as it is can result in accidents due to oxygen deficiency.
When the air conditioner is not to be used for a long
time
If the air conditioner is not to be used for a long time due to a seasonal
change, etc., run it for 4 - 5 hours with the air blowing until the inside is
completely dry. Failing to do so can result in the growth of unhygienic,
unhealthy mold in scattered areas throughout the room.
When it is not to be used for an extended time, keep the [power supply]
turned OFF.
If the power supply is kept on, several watts or several tens of watts will
be wasted. Also, the accumulation of dust, etc., can result in fire.
•Keep the power switched ON for more than 12 hours before starting op-
eration. Do not turn the power supply OFF during seasons of heavy use.
Doing so can result in failure.
1.3. Disposing of the unit
Warning:
When you need to dispose of the unit, consult your dealer. If pipes are re-
moved incorrectly, refrigerant (fluorocarbon gas) may blow out and come
into contact with your skin, causing injury. Releasing refrigerant into the
atmosphere also damages the environment.
2. Names and functions of various parts
Attachment and detachment of filter
[Fig. A] (P.4)
3. How to operate
Before starting operation
Start running after the “PLEASE WAIT” display has disappeared. The “PLEASE
WAIT” display briefly appears on the room temperature display (max. 3 min-
utes) when the power is turned on and after a power failure. This does not
indicate any failure of the air-conditioner.
The choice of indoor unit operation mode is limited by the operation status of
the outdoor unit to which a given indoor unit is connected. If an outdoor unit
and some of the indoor units that are connected to the outdoor units are al-
ready operating in the cooling mode, for example, only the cooling mode is
available for the rest of the units in the same group. If a different mode is re-
quested, the symbol that corresponds to the requested mode will blink, notify-
ing the user that the mode is currently unavailable. The same is true for the dry
and heating mode. This restriction, however, does not apply to the models that
support a simultaneous cooling/heating function.
The outdoor units stop when all the indoor units connected to the counterpart
outdoor units stop.
During heating operation, even if the indoor unit is set to operation while the
outdoor unit is in defrosting operation, operation starts after the defrosting op-
eration of the outdoor unit has ended.
3.1. ON/OFF
Start an operation
1. Press the B [ON/OFF] button
P Operation lamp lights up and operation starts.
Stop an operation
1. Press the B [ON/OFF] button again
Operation lamp goes off and operation stops.
Once the Buttons have been set, pressing of the [ON/OFF] Button only can
repeat the same operation thereafter.
During operation, the operation lamp above the [ON/OFF] button lights up.
Caution:
Even if the [ON/OFF] Button is pressed immediately after the operation is
once stopped, operation is not restarted for about 3 minutes. This function
protects the machine. It automatically starts operation after the lapse of
approximately 3 minutes.
3.2. Selecting operation
When selecting operation
1. Press the 3 [Mode (BACK)] Button
Consecutive press of the selecting operation Button switches the operation
over to E
COOL”, “ DRY”, “ FAN”, (“ AUTO”), and (“ HEAT”). For
the contents of operation, check the display.
For cooling
Press the 3 [Mode (BACK)] Button and bring up the COOL display.
For dry
Press the 3 [Mode (BACK)] Button and bring up the DRYdisplay.
The indoor fan turns to the low-speed operation, disabling the change of fan
speed.
•Dry operation cannot be carried out at room temperature of less than 18 °C
[65 °F].
Caution:
In removing the filter, precautions must be taken to protect your eyes
from dust. Also, if you have to climb up on a stool to do the job, be careful
not to fall.
•Turn off the power supply when the filter is changed.
ON/OFF
CHECK
CLEAR
MENU
ON/OFF
TEST
TEMP.
CLOCK
OPERATION
BACK DAY
MONITOR/SET
1
E
2
3
68
B
P
7
FILTER
ERROR CODE
TIME
ON
OFF
Hr
AFTER
SUN MON TUE WED THU FRI SAT
TIMER
AFTER
ONLY 1Hr.
˚C˚F
WEEKLY
SIMPLE
AUTO OFF
FILTER
FUNCTION
˚C˚F
Loading...
+ 14 hidden pages