Mitsubishi Electric MSC-CB20VB, MSC-CB25VB, MSC-CB35VB Service Manual

SPLIT-TYPE, AIR CONDITIONERS SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS
INDOOR UNIT
SERVICE MANUAL
Wireless type Models
No. OB439
MSC-CB20VB ­MSC-CB25VB ­MSC-CB35VB -
MSC-CB20VB MSC-CB25VB MSC-CB35VB
E1
E1
E1
Outdoor unit service manual
MU-GA·VB Series (OB386) MUH-GA·VB Series (OB387) MUX-A·VB Series (OB384) MXZ-A·WV Series (OB319)
CONTENTS
1. TECHNICAL CHANGES ····································2
2. PART NAMES AND FUNCTIONS······················3
3. SPECIFICATION·················································5
4. NOISE CRITERIA CURVES·······························6
5. OUTLINES AND DIMENSIONS·························7
6. WIRING DIAGRAM ············································8
7. REFRIGERANT SYSTEM DIAGRAM················8
8. SERVICE FUNCTIONS ······································9
9. TROUBLESHOOTING······································11
10. DISASSEMBLY INSTRUCTIONS·····················18
12. OPTIONAL PARTS ···········································22
NOTE:
•This manual describes technical data of indoor units.
1
TECHNICAL CHANGES
MSC-GA20VB - MSC-CB20VB -
MSC-GA25VB - MSC-CB25VB ­MSC-GA35VB - MSC-CB35VB -
1. Panel logo has been changed.
E1E1
E1E1
E1E1
2
2
Emergency operation switch
Fan
Catechin air filter (With deodorizer)
Air outlet
Vertical vanes
Air inlet
to Breaker
Remote control receiving section
Display section
Air cleaning filter(option) (white bellows type)
Front panel
Power supply cord
Panel
Horizontal vane
Operation section
(When the front panel is opened)
Remote controller
Operation indicator lamp Remote control
receiving section
PART NAMES AND FUNCTIONS
MSC-CB20VB MSC-CB25VB MSC-CB35VB
INDOOR UNIT
3
MSC-CB20VB
Installation plate Installation plate fixing screw 4 o 25 mm Remote controller holder Fixing screw for 3 3.5 o 16 mm Battery (AAA) for remote controller Wireless remote controller Felt tape (Used for left or left-rear piping)
1 5 1 2 2 1 1
<Indoor unit>
1
2
3
4
5
6
7
ON/OFF
FAN
TOO
WARM
TOO
COOL
VANE
MODE
ECONO COOL
STOP
START
HR.
MIN.
I FEEL
COOL
DRY
PM
CLOCK
AM
RESET
CLOCK
HEAT /FAN
/
Open the front lid.
ON/OFF
TOO
COOL
PM
AM
TOO
WARM
Signal transmitting section
Operation display section
OPERATE /STOP (ON /OFF) button
TEMPERATURE buttons
Indication of remote controller model is on back.
OPERATION SELECT button
FAN SPEED CONTROL button
OFF-TIMER button
HR. button
MIN. button
(TIME SET button)
ON-TIMER button
RESET button
ECONO COOL button
VANE CONTROL button
CLOCK SET button
MSC-CB25VB MSC-CB35VB
ACCESSORIES
REMOTE CONTROLLER
4
3
Indoor model
Function
Indoor unit power supply
Air flow(High/Med./Low) Power outlet Running current Power input Power factor Fan motor current Model Winding resistance (at 20:) Dimensions WOHOD Weight Air direction Sound level (High/Med./Low) Fan speed (High/Med./Low) Fan speed regulator Remote controller model
K/h
A
A W %
A
"
mm
kg
dB
rpm
MSC-CB20VB
Single phase
230V,50Hz
10
0.17 35 90
0.17
RC4V19-JA
WHT-BLK 283
BLK-RED 188 815O278O244
9 5
3
KP1A
Cooling
474/372/276
36/31/25
900/750/600
Heating
510/420/342
36/31/25
950/820/700
MSC-CB25VB
Single phase
230V,50Hz
10
0.17 35 90
0.17
RC4V19-JA
WHT-BLK 283
BLK-RED 188 815O278O244
9 5
3
KP1A
Cooling
474/384/306
36/31/25
900/770/650
Heating
588/456/342
39/32/25
1,050/870/700
MSC-CB35VB
Single phase
230V,50Hz
10
0.19 40 92
0.19
RC4V19-HA
WHT-BLK 224
BLK-RED 318 815O278O244
10
5
3
KP1A
Cooling
582/444/324
40/33/26
930/760/600
Heating
606/498/396
39/33/26
960/830/700
Electrical
data
Fan
motor
Special
remarks
Capacity
NOTE: 1. Test conditions are based on ISO 5151.
SPECIFICATION
Cooling : Indoor DB27°C WB19°C Heating : Indoor DB20°C
Outdoor DB35°C WB24°C Outdoor DB7°C WB6°C
Indoor-Outdoor piping length : 5m
5
4
90
80
70
60
50
40
30
20
10
63 125 250 500 1000 2000 4000 8000
APPROXIMATE TERESHOLD OF HEARING FOR CONTINUOUS NOISE
NC-60
NC-50
NC-40
NC-30
NC-20
NC-70
OCTAVE BAND SOUND PRESSURE LEVEL, dB re 0.0002 MICRO BAR
BAND CENTER FREQUENCIES, Hz
Test conditions,
Cooling : DB27: WB19: Heating : DB20: WB -:
MSC-CB20VB
COOLING
High
FUNCTIONFAN SPEED
36
HEATING
SPL(dB
(A)) LINE
90
80
70
60
50
40
30
20
10
63 125 250 500 1000 2000 4000 8000
APPROXIMATE TERESHOLD OF HEARING FOR CONTINUOUS NOISE
NC-60
NC-50
NC-40
NC-30
NC-20
NC-70
OCTAVE BAND SOUND PRESSURE LEVEL, dB re 0.0002 MICRO BAR
BAND CENTER FREQUENCIES, Hz
Test conditions.
Cooling : DB27: WB19: Heating : DB20: WB -:
MSC-CB25VB
COOLING
High
FUNCTIONFAN SPEED
36
HEATING 39
SPL(dB
(A)) LINE
90
80
70
60
50
40
30
20
10
63 125 250 500 1000 2000 4000 8000
APPROXIMATE TERESHOLD OF HEARING FOR CONTINUOUS NOISE
NC-60
NC-50
NC-40
NC-30
NC-20
NC-70
OCTAVE BAND SOUND PRESSURE LEVEL, dB re 0.0002 MICRO BAR
BAND CENTER FREQUENCIES, Hz
Test conditions.
Cooling : DB27: WB19: Heating : DB20: WB -:
MSC-CB35VB
COOLING
FUNCTIONFAN SPEED
40
HEATING
High
39
SPL(dB
(A)) LINE
INDOORUNIT
WALL
MICROPHONE
0.8m
1m
NOISE CRITERIA CURVES
6
5
OUTLINES AND DIMENSIONS
MSC-CB20VB MSC-CB25VB
INDOOR UNIT
278
60
58
162
Wireless remote controller
606
783
815
Installation plate
Indoor unit
149
19
Power supply cord Lead to right 1.0m Lead to left 0.3m
81.5
41
81.5
Air in
30
Air out
242 5
7 or more
244
326326
Installation plate
{
90
110
133.5
4.5
271
231.5
42
2.5
81.5
Wall hole
Liquid line Gas line Insulation
Drain hose (Connected part O,D) Insulation
[65
[6.35-0.5m
[9.52-0.43m
[37 O.D
[21 I.D
[16
[28
Unit: mm
MSC-CB35VB
INDOOR UNIT
278
60
58
162
Wireless remote controller
606
783
815
Installation plate
Indoor unit
149
19
Power supply cord Lead to right 1.0m Lead to left 0.3m
41
Air in
30
Air out
7
242
7 or more
244
161.5161.5
326326
5
Installation plate
{
90
110
81.581.5 Wall hole
Liquid line [6.35-0.5m Gas line Insulation
Drain hose (Connected part O,D) Insulation
17.5
258
218.5
42
2.5
[65
[9.52-0.43m
[37 O.D [21 I.D
[16
[28
6
SYMBOL
NR11 RT11 RT12
SR141
NAME
NAME NAME INDOOR FAN CAPACITOR FUSE(T3.15AL250V) INDOOR FAN MOTOR (INNER FUSE) VANE MOTOR
VARISTOR ROOM TEMPERATURE THERMIST OR INDOOR COIL THERMISTOR SOLID STATE RELAY
TERMINAL BLOCK
SYMBOL
C11 F11
MF
MV
SYMBOL
TB
T11
TRANSFORMER
MF
1 2 3 4 5 6
125
CNCN
109
5
REMOTE CONTROLLER
23
POWER MONITOR RECEIVER P.C.BOARD
GRN
LD103
PE
12V
FOR MU OR MUX TYPE
FOR MUH OR MXZ-A TYPE
MV
GRN/YLW
POWER SUPPLY CORD
~/N 230V
50Hz
TO OUTDOOR UNIT CONNECTING
12V
1
2
N
3
L
BRN
BLU
BLK
WHT
BLU
RED
BRN
5
CN 151
1
2
CN202
1
2
3
CN201
LD105
CN211
ELECTRONIC CONTROL P.C. BOARD
F11
T11
NR11
RT11
RT12
CN 112
CN 111
5
3
1
CN 121
BLK GRY YLW BRN
3
WHT RED
C11
SR141
CIRCUIT BREAKER
TB
WIRING DIAGRAM
MSC-CB20VB MSC-CB25VB MSC-CB35VB
INDOOR UNIT
NOTE:1. About the outdoor side electric wiring refer to the outdoor unit electric wiring diagram for servicing.
2. Use copper conductors only. (For field wiring)
3. Symbols below indicate.
/: Terminal block, : Connector
7
REFRIGERANT SYSTEM DIAGRAM
MSC-CB20VB MSC-CB25VB MSC-CB35VB
INDOOR UNIT
Indoor heat exchanger
Room temperature
thermistor RT11
Refrigerant flow in cooling
Refrigerant pipe [9.52 (with heat insulator)
Indoor coil thermistor RT12
Flared connection
Flared connection
Refrigerant pipe [6.35
(with heat insulator)
8
Unit:mm
Loading...