MITSMI PST9327U, PST9328U, PST9329U, PST9330U, PST9331U Datasheet

...
0 (0)

MITSUMI

System Reset PST93XX

 

 

System Reset

Monolithic IC PST93XX Series

Outline

These low reset type ICs function in a variety of CPU systems and other logic systems, to detect power supply voltage and reset the system accurately when power is turned on or interrupted.

They are ideal for use in battery check circuits for products using batteries, as they have ultra-low current consumption and a high precision voltage detection function.

Features

1.

High precision voltage detection

VS±2% max.

 

2.

Ultra-low current consumption

ICCH=2.0µA typ.

ICCL=2.0µA typ.

3.

Low operating limit voltage

0.65V typ.

 

4.

Hysteresis voltage provided in detection voltage

50mV typ.

 

5.

Output current high for ON

5mA min.

 

6.Detection voltage can be selected as desired within a range of 1.9V ~ 4.6V in 0.1V steps, as indicated below.

PST93XX

detection voltage value (Example: for 4.2V ....... PST9342)

Package

SC-82ABA (PST93U)

Applications

1.Reset circuits in microcomputers, CPUs and MPUs.

2.Logic circuit reset circuits.

3.Battery voltage check circuits.

4.Back-up power supply switching circuits.

5.Level detection circuits.

Pin Assignment

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

NC

 

4

3

 

 

 

 

 

 

 

 

 

2

GND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

VOUT

 

1

2

 

 

 

 

 

 

 

4

VCC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SC-82ABA

MITSMI PST9327U, PST9328U, PST9329U, PST9330U, PST9331U Datasheet

MITSUMI

System Reset PST93XX

 

 

Block Diagram

Pin Description

Pin no.

Pin name

Function

 

 

 

1

NC

 

 

 

 

2

GND

GND pin

 

 

 

3

VOUT

Reset signal output pin

 

 

 

4

VCC

Power supply pin/voltage detection pin

 

 

 

Absolute Maximum Ratings (Ta=25°C)

Item

Symbol

Rating

Units

 

 

 

 

Storage temperature

TSTG

-40~+125

°C

Operating temperature

TOPR

-20~+75

°C

Power supply voltage

VCC max.

-0.3~10

V

 

 

 

 

Allowable loss

Pd

150

mW

 

 

 

 

Recommended Operating Conditions

Item

Symbol

Rating

Units

 

 

 

 

Operating temperature

TOPR

-20~+75

°C

Power supply voltage

VCC

+0.85~+10

V

 

 

 

 