Milton CAT G250LG4 User Manual

Sound Test Results
92
Genset:
Enclosure:
Right Left
Pos 4
G250LG 12.9L
Standard Enclosure
Pos 1
GENERATOR END
Pos 2
RADIATOR END
Pos 3
Front
Measured Sound Levels - 60 Hz
90
88
86
84
82
82.3
80
dB (A) @ 7 Meters
78
76
74
72
83.3
Avg. 83.8 dBA
85.0
84.4
1234
Position Number
Notes: 1. All positions 23 ft (7M) from side faces of generator set.
2. Generator operating at full load.
3. Test conducted on a 100 foot diameter asphault surface.
4. Non-enclosed sets do not include exhaust sound during testing.
Actual Average
OLYMPIAN POWER SYSTEMS
OLYMPIAN POWER SYSTEMS
DATA SUBJECT TO CHANGE WITHOUT NOTICE
DATA SUBJECT TO CHANGE WITHOUT NOTICE
0197500SSD 11/12
0197500SSD 11/12