Miele KFN9855IDERH Installation manual

Installation Instructions
KFN 9855 iDE en - CA
Installation, repair and maintenance work should be performed by a Miele authorized service technician in accordance with national and local safety regulations and the provided installation instructions.
Caring for the environment
Disposing of the packaging materials
Ensure that any plastic wrappings, bags, etc. are disposed of safely and kept out of the reach of children. Return the packaging to your dealer.
Disposal of your old appliance
Old appliances may contain materials that can be recycled. Please contact your local recycling authority about the possibility of recycling these materials.
Please take care not to damage the pipework while the appliance is being stored for transport to a waste disposal facility. By protecting the pipework, you help keep the coolants and compressor oil from contaminating the environment.
Before discarding an old appliance disconnect it from the electrical supply and cut off the power cord to prevent it from becoming a hazard.
58
Safe operation of the appliance is only assured if it has been installed and connected in accordance with these Operating and Installation Instructions.
WARNING! Danger of tipping! To avoid a hazard secure the appliance in accordance with these instructions.
WARNING! This appliance is very heavy and can tip forwards when the door / freezer drawers are open. Keep the appliance door shut until the appliance has been installed and secured in the cabinetry in accordance with these Operating and Installation Instructions. The appliance should be installed with the assistance of another person.
This fridge/freezer combination should not be installed side-by-side with another fridge/freezer combination. The appliance does not have heated side walls, a side-by-side arrangement can lead to a build-up of condensation water.
Installation Information
Location
The appliance should not be installed directly next to a heat source (such as a range or a heater) or under a window in direct sunlight. The higher room temperature, the more energy the appliance requires to operate. Most suitable is a dry, well-ventilated room.
The following should also be taken into consideration:
– The plug must be easily accessible
and not concealed behind the appliance so that the appliance can be quickly disconnected from the electrical supply in an emergency. In addition, no other appliances should be plugged into a socket located directly behind this appliance.
– The power cord must not come into
contact with the back of the appliance, it could be damaged by vibrations from the appliance resulting in a short circuit.
Important! When there is high humidity there can be a build-up of
condensation on the outer surfaces of the appliance. This can cause the surfaces to corrode. To prevent this, install the appliance in a dry and/or an air-conditioned room with sufficient ventilation. Please ensure that doors are closing and sealing properly after installation and that the appliance is installed in accordance with these installation instructions and with the required ventilation openings.
59
Installation Information
Climate class
The appliance is designed for use within a certain climate range (room temperature range) and should not be used outside this range. The climate range is specified on the data plate inside the appliance.
Climate class Room temperature
SN
N
ST
T
50 °F to 90 °F
(+10 °C to +32 °C)
61 °F to 90 °F (+16 °C to
+32 °C)
61 °F to 100 °F
(+16 °C to +38 °C)
61 °F to 109 °F
(+16 °C to +43 °C)
If the room is too cold, it will cause the cooling system in the appliance to remain off for too long. This can cause the temperature in the appliance to rise, resulting in damage.
Installation niche
Before installing the appliance, the cabinet must be carefully aligned using a level. The cabinet corners must be at a 90° angle to one another, otherwise the cabinet door will not be flush with all 4 corners of the cabinet. The sidewalls of the installation niche must be even.
Niche floor
To ensure that the appliance is installed safely and to assure all the functions, the floor of the niche where the appliance is to be installed must be even and horizontal.
It must be made from strong, rigid material.
The appliance is extremely heavy when fully loaded, and for this reason it is imperative that the floor it stands on is able to bear its weight. If in doubt, contact Miele.
When fully loaded, the approx. weight of the appliance is 1200 lbs (544 kg).
Adjacent furniture/units
The new appliance will be mounted securely to adjacent furniture/fixtures. For this reason, it is essential that all furniture/fixtures be connected securely to the ground and/or wall.
Door hinge
The appliance is supplied with fixed hinges. If the door needs to be hinged on the opposite side, contact Miele. Do NOT change the door hinging yourself!
60
Proper ventilation
Installation Information
Use only the matching base cover with the ventilation slits! If there is insufficient ventilation, the compressor will run more often and over a longer period of time. This results in higher energy consumption and a higher compressor temperature which can damage the compressor.
This appliance does not require ventilation openings in the surrounding cabinetry. Proper ventilation is ensured though the ventilation slits at the base of the appliance.
WARNING! Danger of damage from overheating. May restrict operation. Keep ventilation openings, in the appliance enclosure or in the built-in structure, clear of obstruction.
61
Installation Dimensions
Before installation, ensure the building-in niche is the correct size. The specified ventilation cross-sections must be adhered to in order to ensure the correct functioning of the appliance.
KFN 9855 iDE
62
AB C D E F
3"
(76 mm)
79 13/16"
(2,027 mm)
29 13/16" (757 mm)
24"
(610 mm)
55 5/8"
(1,413 mm)
37 1/2"
(952 mm)
Installation Dimensions
Opening angle of the door
Ensure that there is sufficient space at the installation location for the door to open wide enough.
a This dimension line indicates the height measured from the floor.
These measurements do not take the cabinet front and the door handle into account; they must be added on accordingly.
63
Niche Dimensions
The location of the electrical outlet can be within a radius of 80" from the appliance top center. Do not install the electrical outlet behind the appliance!
A
Cabinet WidthBInset cabinet
Depth
30"
(762 mm)
If you wish for the appliance panel to be flush with adjacent cabinetry, the adjacent cabinetry depth must equal appliance depth 24" (610 mm) plus panel thickness 5/8" – 3/4" (16 mm - 19 mm).
64
24" (610 mm)
+ panel
thickness
Frameless/Face
B
Cabinet Height
frame cabinet
Depth
24" (610 mm) 80"
(2,032 mm)
C
Door Swing Clearance
a Top view
b Right side wall of appliance housing
c Front of appliance housing
d Front panel - door closed
e Front panel - door opening angle = 115°
f Panel thickness
65
Planning the Water Connection
Water line feed-in (D) from left or right above the anti-tipping bracket.
Do not install the shut-off valve behind the appliance!
The water line lead-through for the water supply line (E) is at the bottom right of the appliance:
66
Information Concerning the door panel
Inset installation
Appliance and panels sit fully within the opening and are flush with what could be its own box, between two pantry cabinets or decorative columns, etc. This is the most common installation scenario.
a Cabinet frame
b Door panel
Stainless steel front panels are available through Miele.
Please take into account the following information concerning the door panel:
– The panels should be at least 5/8"
(16 mm) thick to allow the connecting rails to be fastened to them.
– The maximum panel thickness is 3/4"
(19 mm).
– The door panel weight must not
exceed 60 lb (27 kg).
Cabinet opening A Refrigerator door
panel B
80"
(2,032 mm)
45 1/4"
(1,150 mm)
67