To avoid the risk of accidents or
damage to the appliance, it is
essential to read these
instructions before it is installed
and used for the first time.
en - AU, NZ
M.-Nr. 07 843 130
Contents
Safety instructions for installation....................................3
All connections must be installed by
a suitably qualified and competent
person in strict accordance with
current national and local safety
regulations.
Before installation, check the
~
appliance for visible signs of damage.
Before connecting the appliance,
~
make sure that the connection data on
the data plate (voltage and rated load)
match the mains electricity supply.
This data must correspond in order to
avoid the risk of damage to the
appliance. Consult a qualified
electrician if in any doubt.
The electrical safety of this
~
appliance can only be guaranteed
when continuity is complete between it
and an effective earthing system which
complies with local and national safety
regulations. It is most important that this
basic safety requirement is present and
regularly tested and, where there is any
doubt, the household wiring system
should be inspected by a qualified
electrician. The manufacturer cannot be
held liable for the consequences of an
inadequate earthing system (e.g.
electric shock).
This appliance may be connected
~
via a fused plug and switched socket. If
you wish to connect it to an isolator
switch, or if the appliance is supplied
without a plug, it must be installed and
connected by a suitably qualified and
competent person in strict accordance
with current local and national safety
regulations. The manufacturer cannot
be held liable for damage caused by
incorrect installation or connection.
This appliance must not be installed
~
and used in mobile installations such as
ships etc.
The appliance must be positioned
~
so that you can see the contents of a
cooking container placed on the top
runner. Otherwise you may risk
scalding or burning yourself with hot
water and food when taking containers
out of the oven.
Keep these instructions in a safe place
and pass them on to any future owner.
All dimensions in this instruction booklet
are given in mm.
Do not connect the steam combi
~
oven to the mains electricity supply via
a multi-socket unit or an extension lead.
These do not guarantee the required
safety of the appliance (e.g. danger of
overheating).
The socket and on-off switch should
~
be easily accessible after the appliance
has been built in.
3
Installation note - important!
Front dimensions
4
Room for the fascia panel to
open and shut
Installation note - important!
In the space in front of the fascia panel,
there must be nothing (e.g. door
handle) that would hinder the panel
from opening and shutting.
5
DGC 5080 XL
Appliance and building-in dimensions
Installation in a tall unit
a Steam combi oven
b Building-in recess
c Inlet for mains connection cable to the appliance
d Recommended position for electrical socket
e Mains connection cable
* Appliances with a glass front
** Appliances with a metal front
6
Cut-outs for venting the steam combi oven
DGC 5080 XL
To ensure that the steam combi oven has adequate ventilation, the following
cut-outs measuring 500 x 40 mm must be made:
a In the top of the housing
b In the interim shelf above the building-in recess
Make sure there is no back wall behind the building-in recess.
7
DGC 5080 XL
Installation in a base unit
If the appliance is to be installed under a cooktop, observe the instructions for
installation of the cooktop, as well as the installation height of the cooktop.
a Steam combi oven
b Building-in recess
c Inlet for mains connection cable to the appliance
d Recommended position for electrical socket
e Mains connection cable
* Appliances with a glass front
** Appliances with a metal front
8
DGC 5080 XL
Cut-outs for venting the steam combi oven
To ensure that the steam combi oven has adequate ventilation, the following
cut-outs measuring 500 x 40 mm must be made:
a In the base of the building-in recess
b In the floor of the cupboard space below the building-in recess
Make sure there is no back wall behind the building-in recess.
9
DGC 5080 XL
Installation in a tall unit in combination with an oven
a Steam combi oven
b Building-in recess
c Inlet for mains connection cable to the appliance
d Recommended position for electrical socket
e Mains connection cable
f Oven
* Appliances with a glass front
** Appliances with a metal front
10
Cut-outs for venting the steam combi oven
DGC 5080 XL
To ensure that the steam combi oven has adequate ventilation, the following
cut-outs measuring 500 x 40 mm must be made:
a In the top of the housing
b In the interim shelf above the building-in recess
Make sure there is no back wall behind the building-in recess.
Ventilation cut-out for the oven:
Please refer to the Installation instructions for the oven.