Metrohm tiamo 1.2 Installation

Page 1
System requirements (minimal)
Computer Pentium 4, 1 GHz (or comparable) Operating system Windows 2000 SP1, Windows XP Professional Memory Program: 150 MB
Data: 2 GB (for about 5000 determinations)
The windows user must have administrator rights in order to be able to install the tiamo software.
Additional requirements for the tiamo server:
Network 10 MBit/s, stable and permanent Operating system Windows 2000 SP1, Windows XP Professional,
Windows 2000 Server, Windows 2003 Server
Installation
Single workplace installation
With this version the tiamo workplace and database will be installed on your com­puter.
1. On inserting the CD into the drive of your computer the installation will be started automatically. If this option is deactivated on your computer double click the file setup.exe.
If the minimum system requirements are not met (see above) a message appears. Click on [Yes] if you like to install the programm nevertheless.
Afterwards, click on [Next].
2. After having read the license agreement for tiamo and accepting it with
[Yes] a window will appear where you can enter the license code. Depend­ing on the license code which you have received together with the tiamo
software the assistant will guide you through the installation of the corre­sponding version:
light (single workplace version, max. 2 peripheral instruments) full (single workplace version, peripheral instruments unlimited)
Confirm your entry with [Next].
8.101.0323 tiamo 1.2 09.2006/doe
Page 2
3. Now enter the destination folder for the tiamo installation and confirm with
[Next].
4. In the dialogue window Additional installation information you can define
the path for the database and backup files:
Under Advanced... it is possible to change the ports tiamo uses to com­municate with the database and administration server. If the ports are in use already, an appropriate message will appear. Ask your system administrator for more information about this. Continue with [Next].
5. Follow the instructions of the program until the following message appears:
This message points out which ports tiamo uses. Write down these ports and inform your system administrator in case tiamo is not able to connect to the database. Confirm the message with [OK].
6. As soon as the copying procedure has been terminated you can carry out
further Workplace settings:
2 8.101.0323 tiamo 1.2
Page 3
The option "This computer identifier must exist in the current tiamo system." is only selectable if a database entry already exists from a previ-
ous installation on your computer or if you want to connect to a database server which has already been installed on an other computer.
If you activate this option tiamo checks whether the identifier you have en­tered exists in the database. If this is true the identifier and all associated settings will be adopted. With this option a renewed installation of a client is much easier.
Click [Next]. If the database ports are not available, an appropriate mes­sage will appear and the installation will be aborted. In this case, check your server and firewall settings before starting the installation again.
7. At the end of the installation the file info.txt will be created which contains all relevant information concerning your current tiamo installation. Save this file on your computer in case of need in future and print it (add to IQ). Com­plete the installation with [Finish].
An InstallLog file with a list of all files having been copied to your computer and with a confirmation for a successful installation is saved in the tiamo in­stallation folder (default: C:\Program Files\Metrohm\tiamo) under bin\InstallLog.
Client/Server installation
With the tiamo multi version (multiple workplace version with 3 licenses) you can choose during the installation whether you want to install a client (workplace) or the server (incl. a client) on your computer.
If you only want to install a client the server to which your client will be connected has to be installed in advance.
1. On inserting the CD into the drive of your computer the installation will be started automatically. If this option is deactivated on your computer double click the file setup.exe.
If the minimum system requirements are not met (see above) a message appears. Click on [Yes] if you like to install the programm nevertheless.
Afterwards, click on [Next].
2. After having read the license agreement for tiamo and accepting it with [Yes] a window will appear where you can enter the license code. Enter your tiamo multi license code and click [Next].
3. Now enter the destination folder for the tiamo installation and confirm with [Next].
8.101.0323 tiamo 1.2 3
Page 4
4. The dialogue window Additional installation information appears where you can choose whether you want to install a client or the server:
The option Client/Server installs the workplace and the database server on your computer. Choose this option if your computer will be used as server.
With Client only the workplace will be installed and with
you have to choose the database server (has to be installed in advance!) to which you want to connect. The network server name or the IP address are accepted.
Under Advanced... it is possible to change the ports tiamo uses to com­municate with the database and administration server. If the ports are in use already, an appropriate message will appear. Ask your system administrator for more information about this. Continue with [Next].
5. All further installation steps correspond to those of the single workplace in-
stallation from point 5.
4 8.101.0323 tiamo 1.2
Page 5
Modify / repair / remove installation and renew license
In order to carry out modifications on your current tiamo installation double click the file setup.exe on the installation CD or under Control panel/Add/Remove Pro-
grams click on Metrohm Tiamo 1.2. Then choose Change/Remove:
Modify: With this option you can change the path to the database and backup files
and set the ports which tiamo uses for communication. With the tiamo multi ver­sion you can additionally change the path to the database server.
Repair/Update: In case of a defective tiamo installation because e.g. a DLL file is missing or a program file has been deleted by mistake tiamo can be repaired with this option.
License update: This option allows you to directly update your current tiamo in- stallation to a higher version: light full and full multi. In order to do this enter your new license code in the next dialogue window.
Remove: This removes your tiamo installation. Data which has been generated af- ter the installation (e.g. database entries, log files, exported data etc.) will remain on your hard disk.
8.101.0323 tiamo 1.2 5
Page 6
Program update with tiamo light/full
At the program update, the configuration database (system configuration, methods, templates) and the determination databases are automatically updated for further use with tiamo 1.2. All files in the database directory, in the backup directory, and in the sub-directory bin are maintained. The files in the sub-directories jre, lib, res, doc, and examples are deleted.
1. Save the configuration database into an external directory using the backup
function of tiamo. For that, select the menu item File/Save/Manually in the program part Configuration. Select the Backup directory, enter a name for the backup file and click on [Start]. The backup is finished automatical­ly. It is recommended to copy the backup file to CD/DVD.
2. If desired, export the methods in addition to the automatic backup with the configuration database (see above) into an external directory. For that, se­lect the menu item File/Method Manager in the program part Method. Se­lect the desired Method group, mark all methods to be exported and click on Edit/Export. Select the desired export directory and click on [OK]. The methods are exported into the desired directory. It is recommended to copy the exported methods to CD/DVD.
3. Save all determination databases created by yourself into an external direc­tory using the backup function of tiamo. For that, select the menu item Fi- le/Database Manager in the program part Database. Select the desired database and click on [Backup]. Select the Backup directory, enter a name for the backup file and click on [Start]. The backup is finished auto­matically. It is recommended to copy the backup file to CD/DVD.
4. Save further files created by yourself in the installation directory (e.g. export files) into an external directory or to CD/DVD.
5. Close tiamo 1.1. Insert the installation CD and double click the file se- tup.exe. Then select Repair/Update and click on [Next].
6 8.101.0323 tiamo 1.2
Page 7
6. Complete the installation with [Finish].
An UpdateLog file with a list of all files having been copied to your computer and with a confirmation for a successful installation is saved in the tiamo in­stallation folder (default: C:\Program Files\Metrohm\tiamo) under bin\InstallLog.
Program update with tiamo multi
At the program update, the configuration database (system configuration, methods, templates, user-specific data for all clients) and the determination databases are automatically updated on the server for further use with tiamo 1.2. All files in the da­tabase directory, in the backup directory, and in the sub-directory bin are maintai­ned. The files in the sub-directories jre, lib, res, doc, and examples are deleted.
1. Make sure the tiamo 1.1 will be closed on all clients.
2. Open tiamo 1.1 on the server and save the configuration database into an external directory using the backup function of tiamo. For that, select the menu item File/Save/Manually in the program part Configuration. Select the Backup directory, enter a name for the backup file and click on [Start]. The backup is finished automatically. It is recommended to copy the backup file to CD/DVD.
3. If desired, export the methods in addition to the automatic backup with the configuration database (see above) into an external directory. For that, se­lect the menu item File/Method Manager in the program part Method. Se­lect the desired Method group, mark all methods to be exported and click on Edit/Export. Select the desired export directory and click on [OK]. The methods are exported into the desired directory. It is recommended to copy the exported methods to CD/DVD.
4. Save all determination databases on the server into an external directory using the backup function of tiamo. For that, select the menu item Fi- le/Database Manager in the program part Database. Select the desired database and click on [Backup]. Select the Backup directory, enter a name for the backup file and click on [Start]. The backup is finished auto­matically. It is recommended to copy the backup file to CD/DVD.
5. Save further files created by the users in the installation directory (e.g. ex­port files) into an external directory or to CD/DVD.
6. Close tiamo 1.1 on the server and on all clients. Insert the installation CD and double click the file setup.exe. Then select Repair/Update and click on [Next].
8.101.0323 tiamo 1.2 7
Page 8
7. Complete the installation with [Finish].
An UpdateLog file with a list of all files having been copied to the server and with a confirmation for a successful installation is saved in the tiamo instal- lation folder (default: C:\Program Files\Metrohm\tiamo) under bin\InstallLog.
8. For each client, insert the installation CD and double click the file se- tup.exe. Then select Repair/Update and click on [Next]. Complete the in­stallation with [Finish].
An UpdateLog file with a list of all files having been copied to the client computer and with a confirmation for a successful installation is saved in the tiamo installation folder (default: C:\Program Files\Metrohm\tiamo) under bin\InstallLog.
8 8.101.0323 tiamo 1.2