Maytag PDB3600AWX, PDB3600AWE, PDB3600AWN Dimension Guide

5 (1)
Maytag PDB3600AWX, PDB3600AWE, PDB3600AWN Dimension Guide

www.dexpress.com DIMENSION EXPRESS Fax on Demand (775) 833-3600

 

This Data Sheet Includes Information On

 

 

Side View

 

Maytag

 

23 1/2"

1 13/16"

 

 

(not to scale)

Product Model Number (s):

 

 

 

 

24" Dishwashers:

 

 

 

 

PDB3600AWX. PDB3600AWE and PDB3600AWN

 

 

 

Dimensions (Actual Size)

 

35 1/4" Maximum

 

Height at full leg adjustment:

35 1/4" Maximum

 

 

 

 

1 1/2"

33 3/4" Minimum

 

Height at 0" leg adjustment:

33 3/4" Minimum

 

 

 

 

 

 

 

 

 

Width:

23 7/8"

 

 

 

 

Depth:

23 1/2"

 

 

 

Door thickness incl. control panel:

1 13/16"

 

 

 

 

Door thickness:

1 1/2"

 

 

 

 

Depth with door open:

48 1/2"

 

 

 

 

Vertical toe space:

3" to 4 1/4"

 

48 1/2"

 

 

Custom panel flange depth:

1/4"

 

 

 

Custom panel flange width: 5/16"

Additional Information

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

23 7/8"

 

 

 

 

 

 

 

 

 

 

 

DRAIN:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• 32" Drain loop, 1/2" minimum I.D. Floor drains require

 

 

Front View

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

a siphon break.

 

 

(not to scale)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Drain hose extension kit available 904024.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

When draining into a disposer, make sure disposer

 

 

 

 

 

 

 

 

 

 

 

1/4" Panel Size:

 

 

 

 

 

 

 

 

 

 

drain plug is removed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1/4" Panel Size:

 

WATER SUPPLY:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

35 1/4" Maximum

 

 

 

 

23 9/16" wide

 

 

 

 

 

 

 

 

 

 

• 15 to 120 psi water pressure. 120°F to 140° hot water

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X

 

 

 

 

 

23 11/16" wide

 

supply recommended.

 

 

 

33 3/4" Minimum

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18 3/16" high

 

 

 

 

 

 

 

 

X

 

Access for manual shut-off valve recommended.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4 5/8" high

 

• 3/8" compression to 3/8" male NPT fitting for water

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

valve.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Suggested water line size 3/8" O.D. copper or

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

equivalent.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ELECTRICAL SUPPLY:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3" to 4 1/4"

• 120 volts, 60 Hz protected by a GROUNDED 15 amp

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

fuse or comparable circuit breaker.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Max amperage draw 12.0 amps.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Minimum wire size 14 gauge (No. 12 wire preferred) -

 

 

Rough-in Information

 

Copper only. Check all local codes.

 

Plumbing and

 

(Not to Scale)

 

• Individual branch circuit serving only dishwasher

 

electrical service

 

Preferred

recommended.

 

must enter inside

 

Drain Area

• Electrical and water supplies should enter cabinet

 

shaded area

 

Wall area

 

opening on the floor, or through the side walls as shown

 

 

 

 

 

must be free

 

in shaded areas of drawing

 

3"

 

3"

 

 

of pipes and

• IMPORTANT: ALWAYS CHECK LOCAL AND NATIONAL

 

 

 

wires

 

 

Preferred

 

 

 

CODES FOR FULL COMPLIANCE

 

 

 

 

 

 

Drain Area

 

 

See page 2 for additional information

 

24" Minimum

 

 

7" from floor

 

 

34" - 35"

 

8"

5" from

Subject to change without notice. This system is designed to

 

underside of

 

5"

be updated daily if necessary. Dimension Express is not

 

countertop

 

back wall

responsible for use of superseded, voided, or outdated data

 

to floor

3"

 

sheets. Because of the difficulty or impracticability of deter-

 

 

mining actual damages, liability of Dimension Express shall

 

 

 

24" Minimum

 

not exceed $50.00.

307

 

 

 

Copyright © Dimension Express, 2002.

 

 

 

 

• NEVER reuse Data Sheets. Data Sheets are subject to change without

• Call Dimension Express if you have any questions at (775) 833-3633 •

notice. Dimension Express is a FREE service bureau and is updated daily,

• Always refer to a current Code at a Glance or manufacturer directory •

it makes far more sense to spend the time necessary to request new Data

• Data Sheet codes change on the first of odd numbered months at 12:01am •

Sheets for each project, as opposed to the problems, time, costs, and risks

BN • A307B149 • • 032603 • 95657 • 43687

associated with reusing old Data Sheets.

Loading...
+ 1 hidden pages