Marantz ST-6000 Service Manual

5 (1)

Service

Manual

ST6000/N1B, /N1G

/U1B, /F1N

Tuner

 

TABLE OF CONTENTS

 

1.

TECHNICAL SPECIFICATIONS .............................................................................

1

2.

WIRING DIAGRAM .................................................................................................

2

3.

BLOCK DIAGRAM ..................................................................................................

3

4.

SCHEMATIC DIAGRAM AND PARTS LOCATION .................................................

7

5.

MICROPROCESSOR AND IC DATA ....................................................................

19

6.

ADJUSTMENT PROCEDURE ..............................................................................

21

7.

EXPLODED VIEW AND PARTS LIST ...................................................................

23

8.

ELECTRICAL PARTS LIST ...................................................................................

26

Please use this service manual with referring to the user guide (D.F.U) without fail.

ST6000

R

- ST6000 -

282W855010 AO

3120 785 22160 First Issue:1999.09

MARANTZ DESIGN AND SERVICE

Using superior design and selected high grade components, MARANTZ company has created the ultimate in stereo sound. Only original MARANTZ parts can insure that your MARANTZ product will continue to perform to the specifications for which it is famous.

Parts for your MARANTZ equipment are generally available to our National Marantz Subsidiary or Agent.

ORDERING PARTS :

Parts can be ordered either by mail or by Fax.. In both cases, the correct part number has to be specified. The following information must be supplied to eliminate delays in processing your order :

1.Complete address

2.Complete part numbers and quantities required

3.Description of parts

4.Model number for which part is required

5.Way of shipment

6.Signature : any order form or Fax. must be signed, otherwise such part order will be considered as null and void.

USA

MARANTZ AMERICA, INC. 440 MEDINAH ROAD ROSELLE, ILLINOIS 60172 USA

PHONE : 630 - 307 - 3100 FAX : 630 - 307 - 2687

AMERICAS

SUPERSCOPE TECHNOLOGIES, INC. MARANTZ PROFESSIONAL PRODUCTS 2640 WHITE OAK CIRCLE, SUITE A AURORA, ILLINOIS 60504 USA

PHONE : 630 - 820 - 4800

FAX : 630 - 820 - 8103

AUSTRALIA

JAMO AUSTRALIA PTY LTD 1 EXPO COURT, P.O. BOX 350 MT. WAVERLEY VIC 3149 AUSTRALIA

PHONE : +61 - 3 - 9543 - 1522 FAX : +61 - 3 - 9543 - 3677

JAPAN Technical

MARANTZ JAPAN, INC.

35- 1, 7- CHOME, SAGAMIONO SAGAMIHARA - SHI, KANAGAWA JAPAN 228-8505

PHONE : +81 42 748 1013 FAX : +81 42 748 9190

EUROPE / TRADING

MARANTZ EUROPE B.V. P.O.BOX 80002, BUILDING SFF2 5600 JB EINDHOVEN

THE NETHERLANDS PHONE : +31 - 40 - 2732241 FAX : +31 - 40 - 2735578

CANADA

LENBROOK INDUSTRIES LIMITED 633 GRANITE COURT,

PICKERING, ONTARIO L1W 3K1 CANADA

PHONE : 905 - 831 - 6333

FAX : 905 - 831 - 6936

THAILAND

MRZ STANDARD CO.,LTD

746 - 754 MAHACHAI ROAD., WANGBURAPAPIROM, PHRANAKORN, BANGKOK, 10200 THAILAND

PHONE : +66 - 2 - 222 9181

FAX : +66 - 2 - 224 6795

TAIWAN

PAIYUING CO., LTD.

6 TH FL NO, 148 SUNG KIANG ROAD, TAIPEI, 10429, TAIWAN R.O.C. PHONE : +886 - 2 - 25221304

FAX : +886 - 2 - 25630415

BRAZIL

MARANTZ BRAZIL

CAIXA POSTAL 21462 CEP 04698-970

SAO PAULO, SP, BRAZIL

PHONE : 0800 - 123123(Discagem Direta Gratuita)

FAX : +55 11 534. 8988

SINGAPORE

WO KEE HONG (S) PTE LTD

WO KEE HONG CENTRE

NO.23, LORONG 8, TOA PAYOH

SINGAPORE 319257

PHONE : +65 2544555

FAX

: +65 2502213

MALAYSIA

WO KEE HONG ELECTRONICS SDN. BHD. NO. 102 JALAN SS 21/35, DAMANSARA UTAMA, 47400 PETALING JAYA

SELANGOR DARUL EHSAN, MALAYSIA PHONE : +60 3 - 7184666

FAX : +60 3 - 7173828

KOREA

MK ENTERPRISES LTD.

ROOM 604/605, ELECTRO-OFFICETEL, 16-58, 3GA, HANGANG-RO, YONGSAN-KU, SEOUL KOREA

PHONE : +822 - 3232 - 155

FAX : +822 - 3232 - 154

SHOCK, FIRE HAZARD SERVICE TEST :

CAUTION : After servicing this appliance and prior to returning to customer, measure the resistance between either primary AC cord connector pins ( with unit NOT connected to AC mains and its Power switch ON ), and the face or Front Panel of product and controls and chassis bottom.

Any resistance measurement less than 1 Megohms should cause unit to be repaired or corrected before AC power is applied, and verified before it is return to the user/customer.

Ref. UL Standard No. 1492.

In case of difficulties, do not hesitate to contact the Technical

Department at above mentioned address.

990729A.O

1. TECHNICAL SPECIFICATION

2.WIRING DIAGRAM

FM Section

 

 

Frequency Range ......

87.50MHz-108.00MHz(50kHz steps)

 

87.50MHz-108.00MHz(50kHz steps)

 

76.00MHz-90.00MHz(50kHz steps)

Usable Sensitivity (IHF) ...................................

Mono : 10dBf

Frequency Response .......................................

 

20Hz~15kHz

 

 

+0.5 ~ -3.0dB

T.H.D (at 65dBf, 1KHz)

....................................

Mono : 0.1%

 

 

Stereo : 0.2%

Signal-to-Noise Ratio (at 65dBf, 1kHz) ............

Mono : 70dB

 

 

Stereo : 65dB

AM Suppression Ratio .................................................

 

60dB

Stereo Separation (1kHz) ............................................

40dB

General

 

 

Power Requirements ........................

AC 230V ,50Hz ( /N1 )

 

AC 120V ,60Hz ( /U1 )

 

AC 100V ,50Hz/60Hz ( /F1 )

Power Consumption ........................................................

 

8W

Dimensions (WxHxD) ..................................

 

440x96x311mm

Weight (net) .................................................................

 

3.8Kg

MW Section

 

 

Frequency Range .................

522kHz-1622kHz (9kHz step)

 

520kHz-1710kHz (10kHz step)

Usable Sensitivity (S/N 20dB) ...................................

55dBm

Image Response Ratio

................................................

35dB

T.H.D (400Hz) ..............................................................

 

0.8%

Signal-to-Noise Ratio ...............................

 

40dB (at 85dB/m)

LW Section (/N1 only)

 

 

Frequency Range ...................

146kHz-290kHz (1kHz step)

Usable Sensitivity (S/N 20dB) ...................................

60dBm

T.H.D (400Hz) ..............................................................

 

1.0%

Signal-to-Noise Ratio ...............................

 

40dB (at 85dB/m)

Standard Accessories

 

Audio signal connection cord .............................................

1

Remote control connection cord ........................................

1

FM Antenna ........................................................................

 

1

AM Loop Antenna ..............................................................

 

1

User Guide .........................................................................

 

1

Remocon Unit ( /U1 , /F1 ) (RC6000ST) ............................

1

75-300ohm adaptor ( /U1 , /F1 ) ........................................

1

1

2

3. BLOCK DIAGRAM (/N1B,/N1G) VERSION

3

4

(/U1B,/F1N) VERSION

5

6

Marantz ST-6000 Service Manual

4. SCHEMATIC DIAGRAM AND PARTS LOCATION (/N1B,/N1G) VERSION

7

8

(/U1B) VERSION

9

10

Loading...
+ 14 hidden pages