Service
Manual
ST6000/N1B, /N1G
/U1B, /F1N
Tuner
|
TABLE OF CONTENTS |
|
1. |
TECHNICAL SPECIFICATIONS ............................................................................. |
1 |
2. |
WIRING DIAGRAM ................................................................................................. |
2 |
3. |
BLOCK DIAGRAM .................................................................................................. |
3 |
4. |
SCHEMATIC DIAGRAM AND PARTS LOCATION ................................................. |
7 |
5. |
MICROPROCESSOR AND IC DATA .................................................................... |
19 |
6. |
ADJUSTMENT PROCEDURE .............................................................................. |
21 |
7. |
EXPLODED VIEW AND PARTS LIST ................................................................... |
23 |
8. |
ELECTRICAL PARTS LIST ................................................................................... |
26 |
Please use this service manual with referring to the user guide (D.F.U) without fail.
ST6000
R
- ST6000 -
282W855010 AO
3120 785 22160 First Issue:1999.09
MARANTZ DESIGN AND SERVICE
Using superior design and selected high grade components, MARANTZ company has created the ultimate in stereo sound. Only original MARANTZ parts can insure that your MARANTZ product will continue to perform to the specifications for which it is famous.
Parts for your MARANTZ equipment are generally available to our National Marantz Subsidiary or Agent.
ORDERING PARTS :
Parts can be ordered either by mail or by Fax.. In both cases, the correct part number has to be specified. The following information must be supplied to eliminate delays in processing your order :
1.Complete address
2.Complete part numbers and quantities required
3.Description of parts
4.Model number for which part is required
5.Way of shipment
6.Signature : any order form or Fax. must be signed, otherwise such part order will be considered as null and void.
USA
MARANTZ AMERICA, INC. 440 MEDINAH ROAD ROSELLE, ILLINOIS 60172 USA
PHONE : 630 - 307 - 3100 FAX : 630 - 307 - 2687
AMERICAS
SUPERSCOPE TECHNOLOGIES, INC. MARANTZ PROFESSIONAL PRODUCTS 2640 WHITE OAK CIRCLE, SUITE A AURORA, ILLINOIS 60504 USA
PHONE : 630 - 820 - 4800
FAX : 630 - 820 - 8103
AUSTRALIA
JAMO AUSTRALIA PTY LTD 1 EXPO COURT, P.O. BOX 350 MT. WAVERLEY VIC 3149 AUSTRALIA
PHONE : +61 - 3 - 9543 - 1522 FAX : +61 - 3 - 9543 - 3677
JAPAN Technical
MARANTZ JAPAN, INC.
35- 1, 7- CHOME, SAGAMIONO SAGAMIHARA - SHI, KANAGAWA JAPAN 228-8505
PHONE : +81 42 748 1013 FAX : +81 42 748 9190
EUROPE / TRADING
MARANTZ EUROPE B.V. P.O.BOX 80002, BUILDING SFF2 5600 JB EINDHOVEN
THE NETHERLANDS PHONE : +31 - 40 - 2732241 FAX : +31 - 40 - 2735578
CANADA
LENBROOK INDUSTRIES LIMITED 633 GRANITE COURT,
PICKERING, ONTARIO L1W 3K1 CANADA
PHONE : 905 - 831 - 6333
FAX : 905 - 831 - 6936
THAILAND
MRZ STANDARD CO.,LTD
746 - 754 MAHACHAI ROAD., WANGBURAPAPIROM, PHRANAKORN, BANGKOK, 10200 THAILAND
PHONE : +66 - 2 - 222 9181
FAX : +66 - 2 - 224 6795
TAIWAN
PAIYUING CO., LTD.
6 TH FL NO, 148 SUNG KIANG ROAD, TAIPEI, 10429, TAIWAN R.O.C. PHONE : +886 - 2 - 25221304
FAX : +886 - 2 - 25630415
BRAZIL
MARANTZ BRAZIL
CAIXA POSTAL 21462 CEP 04698-970
SAO PAULO, SP, BRAZIL
PHONE : 0800 - 123123(Discagem Direta Gratuita)
FAX : +55 11 534. 8988
SINGAPORE
WO KEE HONG (S) PTE LTD
WO KEE HONG CENTRE
NO.23, LORONG 8, TOA PAYOH
SINGAPORE 319257
PHONE : +65 2544555
FAX |
: +65 2502213 |
MALAYSIA
WO KEE HONG ELECTRONICS SDN. BHD. NO. 102 JALAN SS 21/35, DAMANSARA UTAMA, 47400 PETALING JAYA
SELANGOR DARUL EHSAN, MALAYSIA PHONE : +60 3 - 7184666
FAX : +60 3 - 7173828
KOREA
MK ENTERPRISES LTD.
ROOM 604/605, ELECTRO-OFFICETEL, 16-58, 3GA, HANGANG-RO, YONGSAN-KU, SEOUL KOREA
PHONE : +822 - 3232 - 155
FAX : +822 - 3232 - 154
SHOCK, FIRE HAZARD SERVICE TEST :
CAUTION : After servicing this appliance and prior to returning to customer, measure the resistance between either primary AC cord connector pins ( with unit NOT connected to AC mains and its Power switch ON ), and the face or Front Panel of product and controls and chassis bottom.
Any resistance measurement less than 1 Megohms should cause unit to be repaired or corrected before AC power is applied, and verified before it is return to the user/customer.
Ref. UL Standard No. 1492.
In case of difficulties, do not hesitate to contact the Technical
Department at above mentioned address.
990729A.O
1. TECHNICAL SPECIFICATION |
2.WIRING DIAGRAM |
|
FM Section |
|
|
Frequency Range ...... |
87.50MHz-108.00MHz(50kHz steps) |
|
|
87.50MHz-108.00MHz(50kHz steps) |
|
|
76.00MHz-90.00MHz(50kHz steps) |
|
Usable Sensitivity (IHF) ................................... |
Mono : 10dBf |
|
Frequency Response ....................................... |
|
20Hz~15kHz |
|
|
+0.5 ~ -3.0dB |
T.H.D (at 65dBf, 1KHz) |
.................................... |
Mono : 0.1% |
|
|
Stereo : 0.2% |
Signal-to-Noise Ratio (at 65dBf, 1kHz) ............ |
Mono : 70dB |
|
|
|
Stereo : 65dB |
AM Suppression Ratio ................................................. |
|
60dB |
Stereo Separation (1kHz) ............................................ |
40dB |
|
General |
|
|
Power Requirements ........................ |
AC 230V ,50Hz ( /N1 ) |
|
|
AC 120V ,60Hz ( /U1 ) |
|
|
AC 100V ,50Hz/60Hz ( /F1 ) |
|
Power Consumption ........................................................ |
|
8W |
Dimensions (WxHxD) .................................. |
|
440x96x311mm |
Weight (net) ................................................................. |
|
3.8Kg |
MW Section |
|
|
Frequency Range ................. |
522kHz-1622kHz (9kHz step) |
|
|
520kHz-1710kHz (10kHz step) |
|
Usable Sensitivity (S/N 20dB) ................................... |
55dBm |
|
Image Response Ratio |
................................................ |
35dB |
T.H.D (400Hz) .............................................................. |
|
0.8% |
Signal-to-Noise Ratio ............................... |
|
40dB (at 85dB/m) |
LW Section (/N1 only) |
|
|
Frequency Range ................... |
146kHz-290kHz (1kHz step) |
|
Usable Sensitivity (S/N 20dB) ................................... |
60dBm |
|
T.H.D (400Hz) .............................................................. |
|
1.0% |
Signal-to-Noise Ratio ............................... |
|
40dB (at 85dB/m) |
Standard Accessories |
|
|
Audio signal connection cord ............................................. |
1 |
|
Remote control connection cord ........................................ |
1 |
|
FM Antenna ........................................................................ |
|
1 |
AM Loop Antenna .............................................................. |
|
1 |
User Guide ......................................................................... |
|
1 |
Remocon Unit ( /U1 , /F1 ) (RC6000ST) ............................ |
1 |
|
75-300ohm adaptor ( /U1 , /F1 ) ........................................ |
1 |
1 |
2 |
3. BLOCK DIAGRAM (/N1B,/N1G) VERSION
3 |
4 |
(/U1B,/F1N) VERSION
5 |
6 |
4. SCHEMATIC DIAGRAM AND PARTS LOCATION (/N1B,/N1G) VERSION
7 |
8 |
(/U1B) VERSION
9 |
10 |