LG ARNU243M2A4, ARNU483BRA2 Owner's Manual

0 (0)

OWNER’S MANUAL

AIR CONDITIONER

Read this owner’s manual thoroughly before operating the appliance and keep it handy for reference at all times.

TYPE : Ceiling Concealed Duct

EN ENGLISH

FR FRANÇAIS ES ESPAÑOL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

www.lghvac.com

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

www.lg.com

 

MFL69889202

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rev.08_061220

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Copyright © 2017 - 2020 LG Electronics Inc. All rights reserved.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TABLE OF CONTENTS

3 SAFETY INSTRUCTIONS

3 IMPORTANT SAFETY INSTRUCTIONS

8 PRIOR TO OPERATION

8 Preparing for operation

8 Usage

8 Cleaning and maintenance

8 Service

8FOR YOUR RECORDS

9OPERATION DETAILS

9Operation range

9Usage Limitations

10OPERATION

10Parts and Functions

11MAINTENANCE

11Cleaning the Air Filter

12When air conditioner is not going to be used for a long period of time

12When using the air conditioner after a long period of non-use

12Operation Tips

13TROUBLESHOOTING

13Before Calling for Service

14WARRANTY (USA)

16 WARRANTY (CANADA)

SAFETY INSTRUCTIONS 3

SAFETY INSTRUCTIONS

READ ALL INSTRUCTIONS BEFORE USE

Your safety and the safety of others are very important.

We have provided many important safety messages in this manual and on your appliance. Always read and follow all safety messages.

This is the safety alert symbol.

This symbol alerts you to potential hazards that can kill or injure you and others.

All safety messages will follow the safety alert symbol and either the word WARNING, or CAUTION.

WARNING

Failure to follow these instructions could result in death or serious injury.

CAUTION

Failure to follow these instructions could result in minor or moderate injury or damage to the product.

All safety messages will tell you what the potential hazard is, inform you as to how to reduce the chance of injury, and tell you what may happen if the instructions are not followed.

<![if ! IE]>

<![endif]>ESPAÑOL FRANÇAIS ENGLISH

IMPORTANT SAFETY INSTRUCTIONS

WARNING

To reduce the risk of explosion, fire, death, electric shock, scalding or injury to persons when using this product, follow basic precautions, including the following:

•• Installation or repairs done by unauthorized persons can pose hazards to you and others.

•• Installation MUST conform to the local building codes or, in the absence of local codes, the National Electrical Code NFPA 70/ANSI C1-1003 or current edition and Canadian Electrical Code Part 1 CSA C22. 1.

•• The information contained in this manual is intended for use by a qualified service technician who is familiar with the safety procedures and equipped with the proper tools and test instruments.

•• Failure to read and follow all instructions in this manual can result in equipment malfunction, property damage, personal injury and/or death.

•• When the power cord needs to be replaced, the replacement work should be performed by authorized personnel using only genuine replacement parts.

•• This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety. Children should be supervised to

ensure that they do not play with the appliance.

4 SAFETY INSTRUCTIONS

Important Safety Instructions

WARNING

Installation

Contact the dealer to have the air conditioner installed.

•• Incomplete installation performed by yourself may result in a water leakage, electric shock, and fire.

Check the foundation for damaged on a continuous basis, especially if it has been in use for a long time.

•• It may cause injury or damage to the unit or other property.

Contact the dealer for repairs, maintenance and to reinstall the airconditioner.

•• Incomplete installation performed by yourself may result in a water leakage, electric shock, and fire.

Be sure to only use accessories made by LG which are specifically designed for use with the equipment and have them installed by a professional.

•• Improper installation or attachment of equipment or accessories could result in electric shock, a short circuit, leaks, fire or other damage to the equipment.

In the case of refrigerant leakage, consult the dealer. When installing the air conditioner in a small room, it is necessary to take proper measures so that even when it leaks, the amount of any leaked refrigerant does not exceed the limiting concentration even when it leaks. If the refrigerant leakage exceeds the limiting concentration level, an oxygen deficiencyrelated accident may occur.

•• There is a risk of asphyxiation which could lead to serious injury or death.

Do not install the unit in an area where there are flammable materials.

•• There is a risk of explosion that could result in serious injury or death.

Use a vacuum pump or insert (nitrogen) gas when performing a leakage test or air purge. Do not allow air etc. to enter the refrigerant circuit (piping). Never use refrigerants that are not specified on the specification. label and in the manuals.

•• There is a risk of death, injury, fire or explosion.

Power

Do not attempt to do electrical work or grounding work unless you are licensed to do so. Consult with the dealer for electrical work and grounding work.

•• There is a risk.

Do not modify or extend the power cable.

•• There is risk of fire or electric shock.

Be sure to establish an earth.

•• There is risk of fire or electric shock.

Be sure to install an earth leakage breaker.

•• There is risk of fire or electric shock.

Always install a dedicated circuit and breaker.

•• Improper wiring or installation may cause fire or electric shock.

Do not turn on the breaker or power if the front panel, cabinet, top cover, or control box cover are removed or opened.

•• Doing so could cause fire, electric shock, explosion or death.

Do not use a defective or underrated circuit breaker. Use this appliance on a dedicated circuit.

•• There is a risk of fire or electric shock.

Consult with the installation contractor for cleaning or maintenance. Turn off all electrical power before doing any cleaning or maintenance.

•• There is a risk of water leakage, electric shock or serious injury.

Take care to ensure that the power cable cannot be pulled out or damaged during operation.

•• There is a risk of fire or electric shock.

Do not place anything on the power cable.

•• There is a risk of fire or electric shock.

Do not turn off the power immediately after stopping operation. Always wait for at least five minutes before turning off the power.

•• Otherwise, water leakage may occur.

Indoor/outdoor wiring connections must be secured tightly and the cable should be routed properly so that there is no force pulling the cable from the connection terminals.

•• Improper or loose connections can cause heat generation or fire.

Do not touch (operate) the product with wet hands.

•• There is a risk of electrical shock.

LG ARNU243M2A4, ARNU483BRA2 Owner's Manual

 

SAFETY INSTRUCTIONS 5

Operation

If the product becomes soaked (flooded or

 

 

submerged), contact the dealer.

Be sure to use only those parts which are listed in the SVC parts list. Never attempt to modify the equipment.

•• The use of inappropriate parts can cause an electrical shock or fire.

Do not install the air conditioner at any place where flammable gas may leak out. If the gas leaks out and stays around the air conditioner, a fire may break out.

•• There is a risk of explosion, fire and serious injury.

Never use flammable spray such as hair spray, lacquer or paint near the unit.

•• Flammable spray may cause a fire.

If equipment utilizing a burner is used in the same room as the air conditioner,

there is the danger of oxygen deficiency, which could lead to asphyxiation. Be sure to ventilate the room sufficiently to avoid this hazard.

•• There is a risk of serious injury or death.

Do not put fingers or other objects into the air inlet or air outlet. Never remove the fan guard of the unit.

•• The fan rotates at a high speed and will cause injury.

Never sprinkle or spill water or liquids on unit.

•• Doing so could cause fire, failure of the product, or electric shock.

Never let the indoor unit or the remote controller get wet.

•• Water can cause an electric shock or a fire.

Do not let the air conditioner run while a door or window is open on a day with high humidity.

This could result in excessive moisture and water damage.

•• Excess moisture may collect and cause water damage to walls or furniture.

If there are any abnormalities in the operation of the air conditioner such as strange sounds, smoke or fire. turn off the power and contact the dealer immediately.

•• There is a risk of severe injury or death.

Take care to ensure that nobody can step on or fall onto the outdoor unit.

•• This could result in personal injury and product damage.

Stop operation and close all window in storm or hurricane. If possible, remove the product from the window before the hurricane arrives.

•• There is a risk of property damage, product failure, or electric shock.

•• There is a risk of fire or electric shock.

Do not use the product in a tightly closed space for a long time.

•• Doing so could result in a state of oxygen deficiency.

Maintenance

The heat exchanger fins are sharp edges enough to cut. To avoid injury, wear gloves or cover the fins while working around them.

Tear apart and throw away plastic packaging bags so that children will not play with them.

•• Children playing with plastic bags are at risk of death by suffocation.

Safely dispose of the packing materials. Packing materials, such as nails and other metal or wooden parts.

•• These materials could cause puncture wounds or other injuries.

<![if ! IE]>

<![endif]>ESPAÑOL FRANÇAIS ENGLISH

6

 

SAFETY INSTRUCTIONS

 

 

 

CAUTION

The Limited Warranty is void and of no effect, and

 

 

LG will have no liability hereunder to any Customer

 

Installation

or third party, to the extent any of the following occur:

 

acts, omissions, and conduct of any and all third

 

If the refrigerant gas leaks during the installation,

parties including, but not limited to, the installing

 

contractor and any repairs, service or maintenance

 

ventilate the area immediately.

 

by unauthorized or unqualified persons.

 

•• Such leakage it can be harmful for your health.

 

Do not install the unit in potentially explosive

 

Always check for gas (refrigerant) leakage after

 

atmospheres.

 

installation or repair of product.

 

•• Low refrigerant levels may cause product failure.

Keep the product level, even when installing it.

•• This will help to avoid vibration or water leakage.

Use two or more people to lift and transport the product.

•• This will help to avoid personal injury.

Operation

If refrigerant gas leaks while the unit is being repaired do not touch the leakaing refrigerant gas.

•• The refrigernat gas can cause frostbite (cold burn)

Do not mix air or gases other than the specified refrigerant used in the system.

Installation work must be performed in accordance with the National Electric Code by qualified and authorized personnel only.

Do not place objects in direct proximity of the outside unit. Do not let leaves and other debris accumulate around the unit. Leaves are a hotbed for small animals, which can enter the unit. Once inside the unit, these animals can lead to the unit malfunctioning, and end up causing in smoke or fire when they make contact with electrical parts.

•• There is a risk of fire or electric shock.

Do not install the product where it will be exposed to sea wind (salt spray) directly.

•• This can cause corrosion on the product. Corrosion, particularly on the condenser and evaporator fins, could cause product malfunction or inefficient operation.

Make sure that the drainpipe is installed properly to drain water. Arrange the drain hose to ensure smooth drainage.

•• Incomplete drainage may lead to water damage done to the building, furniture, etc. If no water is discharged from the drainpipe while the air conditioner or heat pump is in the cooling mode, it may be because the drainpipe has become clogged with dust or dirt, and could result in water leakage in the indoor unit. In such a situation, stop operating the air conditioner or heat pump and contact the dealer.

Do not install the product where the noise or hot air from the outdoor unit could be harmful to your immediate surroundings.

•• Improper placement could cause problems for your neighbors.

•• Air entering the refrigerant system can lead to excessively high pressure causing equipment damage or injury.

Make sure that there are no obstacles close to the outdoor unit. The presence of obstacles close to the outdoor unit may reduce the performance of outdoor unit or increase its operating sound.

•• This could cause product failure.

Do not use the air conditioner for any other purposes other than comfort cooling or heating. Do not use the unit for cooling precision instruments, food, plants, animals or works of art.

•• Doing so could lead to risk of damage or loss of property.

Replace all the batteries in the remote control with new ones of the same type. Do not mix old and new batteries or different types of batteries.

•• Doing so could lead to a risk of fire or explosion.

Do not recharge or disassemble the batteries. Do not dispose of batteries in a fire.

•• They may burn or explode.

If the liquid from the batteries gets onto your skin or clothes, wash it well with clean water. Do not use the remote if the batteries have leaked.

•• The chemicals in batteries could cause burns or other health hazards.

Loading...
+ 12 hidden pages