Kyocera FS-C2026, FS-2126MFP ServiceBulletin 2KW-004

Service Bulletin
SB Number:
Subject:
SB 2KW-004
Calibration errors due to the bent Belt cleaner ID
Creation Date: 15/09/2010
Phenomenon Several calibration errors may occur.
Examples
• Failure to perform the image density adjustment.
• Failure to perform the colour registration.
Cause The end of the belt cleaner ID has been bent. Under this condition, the belt cleaner ID may be
caught by the guide feed and motion failure of the shutter cleaner ID may occur. This can be corrected by pressing the belt cleaner ID down to the original shape. Therefore please check the condition of the above mentioned part when replacing the parts ID sensor assy SP.
Solution The length of the belt cleaner ID has been changed from 3mm to 1.8mm.
When the belt cleaner ID is bent, several calibration errors may occur.
Classication
Field measure When the above mentioned phenomena occur, please return the belt cleaner ID to the original
Entire stock rework
shape or replace the belt cleaner ID with the latest type.
In-eld modication at next visit
In-eld modication by case
X
No modication necessary
Serial numbers of affected machines
Type Serial number
FS-C2026MFP/2126MFP Not available
KMIS Service Department, Kyocera Mita Europe A273 / SB 2KW-004
Page 1 of 2
Service Bulletin
Back of the machine.
View after removing the primary transfer unit.
Shutter cleaner ID
ID sensor ASSY
Check if the edge of the belt cleaner ID is bent.
KMIS Service Department, Kyocera Mita Europe A273 / SB 2KW-004
Solution: The length of the belt cleaner ID has been changed.
Old length: 3mm New length: 1.8mm
Page 2 of 2