Phenomenon 1. A full page solid image may appear on the print-out.
2. A developer leak image may appear on the print-out.
Cause The Drum unit may not be charged, or a Charge leak may occur between the drum and the
developer sleeve.
Solution Please check if there is contact failure at the high voltage board and follow the procedure
below.
Full page solid image
Developer leak image
Classication
Field measure When the above mentioned phenomena occur, please check of there is contact failure at the
KMIS Service Department, Kyocera Mita Europe B157 / SB 2KW-014
Entire stock rework
high voltage board. Please follow the procedure below.
In-eld modication at next visit
Page 1 of 2
In-eld modication by case
X
No modication necessary
Service Bulletin
NG
NG: Leading edge of the spring is caught by the plastic wall
OK: Leading edge of the spring enters the hole.
Wall
Spring
If the leading edge of the spring is caught by the wall, use a minus screw driver to release it. Push the spring down the hole properly.