Increased toner consumption due to T7 control
Creation Date: 21/10/2011
Phenomenon When at machine start-up low print coverage is detected and the fusing temperature is 50 °C
or more or when the machine recovers from from sleep mode, the T7 toner disposal mode is executed every 5 pages. In this case, the toner band width for disposal is at the maximum level until the machine enters sleep mode. Under this condition, too much toner may be
consumed.
Note If bias calibration is executed after a print job of 80 pages, when the machine starts-up or
recovers from sleep mode, the toner band width of the T7 control returns to normal.
Solution Upgrade the Engine rmware to the latest version.
Firmware
Type Program No. Version Applicable model(s) Applicable Service Bulletin
ENGINE 2KW_1000.007.004 007.004 FS-C2026MFP/2126MFP SB 2KW-012
Classication
Field measure When the above mentioned phenomenon occurs, please upgrade the Engine rmware to the
Entire stock rework
latest version.
In-eld modication at next visit
In-eld modication by case
X
No modication necessary