Service Bulletin
SB Number:
Subject:
SB 5JK-005
Latest registered service part and added protection sheet
Creation Date: 23/06/2010
Model: FS-C1020MFP
1. To improve the parts exchange efciency, the scanner relay wire has been registered as
Harness scanner 305JK74720.
2. To protect the above mentioned part, the protecion sheet (Sheet:cover:harness:ADF 305JK73900) has been
added.
1. Harness Scanner 305JK74720
2. Added protection sheet to protect the
harness scanner.
Parts
No. Old Parts
No.
1 ------------ 305JK74720
2 ------------ 305JK73900
New Parts
No.
5JK74720
5JK73900
Description Q’TY Interchange-
ability
Old New Old New
HARNESS SCANNER (scanner relay wire) - 1 - O -
SHEET:COVER:HARNESS:ADF (protecion
sheet)
- 1 - O -
SP
KMIS Service Department, Kyocera Mita Europe A122-A172 / SB 5JK-005
Page 1 of 2
Service Bulletin
Classication
Field measure To protect the scanner relay wire, please attach the sheet:cover:harness:ADF 305JK73900
Serial numbers of affected machines
Type Part Serial number
FS-C1020MFP HARNESS SCANNER This part is only for use in the eld.
FS-C1020MFP SHEET:COVER:HARNESS:ADF May 2010 production.
Machines produced after the above mentioned prodction date, should be affected by the above mentioned changes.
Attaching the protection sheet
1 Open the top cover, remove the
screw (B) and remove the slide rail
(D) while lifting up the arm (C).
Entire stock rework
according to the procedure mentioned below.
In-eld modication at next visit
In-eld modication by case
X
C
D
No modication necessary
2 Clean the protection sheet and
the top cover surface where the
sheet will be attached with cleaning
alcohol.
Remove the release paper from the
double faced tape surface on top of
the protection sheet (E). Insert the
protection sheet with the bottom of
the sheet between the hinge spring
(F) and the scanner relay wire (G).
3 Insert the double face tape
surface of the protection sheet to
the back of the rib (H) of the top
cover. Reseat and secure the slide
rail (D) with the screw and return
the arm (C) to the home position.
Check if the scanner relay wire (G)
is behind the protection sheet.
B
E
G
F
H
G
KMIS Service Department, Kyocera Mita Europe A122-A172 / SB 5JK-005
Page 2 of 2