Kyocera FS-3040, FS-3140MFP Service Bulletin 2LW 001

Service Bulletin
SB Number:
Subject:
SB 2LW-001
Firmware upgrade
Creation Date: 15/09/2010
Item Contents
1 Trial based applications. When the date in the machine has been changed, the time to use trial
based applications will be set to 0.
2 Error code CF248. Error code CF248 may occur when printing.
3 Machine does not reach “Ready“
status.
Firmware
Type Program No. Check SUM Version Status Date Applicable models
ENGINE 2LW_1000.002.001 c43f 002.001 04/06/2010 FS-3040MFP/3140MFP
MAIN 2LW_2F00.002.007 ---- 002.007 ---------- FS-3040MFP
MAIN 2LX_2F00.002.007 ---- 002.007 ---------- FS-3140MFP
FAX 2H9_54000003003 ---- ------- ---------- FS-3140MFP
Machines using KYOmulticode may not reach the “Ready” status when the fax board is installed.
Classication
Field measure When the above mentioned phenomena occur, please upgrade the rmware to the latest version.
Serial numbers of affected machines
Type Serial number Installed rmware
FS-3040MFP Q8E0600320 Main and engine
FS-3140MFP Q8L0701063 Main and engine
Machines produced after the above mentioned serial numbers, should not have the above mentioned phenomena.
Entire stock rework
In-eld modication at next visit
In-eld modication by case
No modication necessary
KMIS Service Department, Kyocera Mita Europe A247 / SB 2LW-001
Page 1 of 1
Loading...