Kyocera FS-3040, FS-3140MFP Service Bulletin 2LW 0011 B382

(KMKR),
DP.)
motion failure
Check
SUM
Current
Ver,
Option
al language
KR
2LW_81KR00101
5
Option
al language
TW
2LW_81TW0010
1
3
Option
al language
BR
2LW_81BR00101
5
Option
al language
CN
2LW_81CN00101
2
Service Bulletin Ref. No.
Subject
(Page.1/2)
2LW-0011 (B382)
<Date> November 10, 2011
Firmware Upgrade (FAX: Ver.007.002 (Except KTST); Scanner: Ver.002.001; Optional Language: Ver.001.015 Ver.001.013( KMTW))
FS-3040MFP_FS-3140MFP_v.08.00.0030_(2011-02-07)
Model
FS-3040MFP, FS-3140MFP
Topic
The firmware was upgraded as follows.
Content of Changes
No. Item Details
1 Support for Mexico The Mexican country code was added.
2
Measure against the copy image dropout (Only leading edge or trailing edge of the image was printed.)
3
Measures against the solenoid
4
Support for KMKR and KMTW Change was made in order to support the FS-3140MFP+.
If DP was closed during scanning the original and copy was started in the state of opening DP after putting the original on the contact glass, only the image at the time of closing DP might be printed, or only the trailing edge of the original might be printed depending on the timing of closing DP. Therefore, this was corrected. (No particular problem is expected if copy is executed by using
The DP reverse solenoid might not be released after completing the duplex scanning. Therefore, this was corrected.
Program No.
ENGINE 2LW_1000004001 6EAA 004.001 2011/6/10 003.003
MAIN 2LW_2F00008003 008.003 - 007.010 FS-3040MFP
MAIN 2LX_2F00008003 008.003 - 007.010 FS-3140MFP
SCANER 2LW_1200002001 002.001 2011/6/10 001.013
001.015 - 001.014 For KMKR
001.013 - 001.009 For KMTW
001.015 - - For KMBR
001.012 - 001.010 For KTST
FAX BOOT/APL 2H9_5500007002 007.002 - 006.001 Except KTST
FAX BOOT/APL 2H9_5700N05001 N05.001 - N04.002 For KTST
Ver. Status Date
Remark
For the KM sales companies, it is possible to download the firmware at the download center on the ESDC.net. When upgrading the firmware or replacing a board, please upgrade all kinds of the firmware to the latest version at the same time.
CTL No.
556269
488853
TC-10-034
538810
←←←← New upgrade
←←←← New upgrade
←←←← New upgrade
←←←← New upgrade
FW
FAX
SCA
SCA
LAN
European Service & Development Center (ESDC)
Service Bulletin Ref. No.
KMC’s Classification Entire Stock Rework In-Field modification at next visit
Field Measure: Please upgrade the firmware when the problem described above arises.
Serial Nos. of the Affected Machines: Planned from the October 2011* production
(Page.2/2)
2LW-0011 (B382)
<Date> November 10, 2011
In-Field modification by case No modification necessary
*The above is the plan at the present moment. Please note that this information is subject to change.
European Service & Development Center (ESDC)