KROHNE ENVIROMAG 2000 Data sheet

OPTIFLUX Electromagnetic Flowmeter
Application Information Sheet
Company name:
Address:
General Information
Equipment tag #
Piping information,
Meter orientation,
Agency approvals,
Process conditions
Flow conditions,
Flow rate,
System pressure,
Fluid temperature,
Fluid properties,
Any solids present?
Is fluid abrasive?
Entrained air present?
Signal converter/ transmitter
Converter type,
Converter housing,
Power supply,
IO communications,
Base IO module:
1st. IO module:
2nd IO module:
Reference method,
Flow sensor
Liner material,
Hard rubber
Electrodes,
Grounding rings,
Sensor housing,
Flange material,
Process connections,
FDA approval
Pipe size:
Horizontal
Without
Continous service
Normal
Normal
Normal
Density
Integral-mounted
Die-cast aluminum
12-24 VDC
HART
Standard method
PFA
Hastelloy C22
Without
Carbon steel
Carbon steel
Size:
Raised face
Wafer-style
ASME 150#
316L SST
316L SST
316 Ti SST
Stainless steel
Rilsan
PTFE (Teflon)
Virtual reference method
RS485 Modbus
100-230 VAC
Stainless steel
Field-mounted
NoNoNo
Batching service
NSF drinking water
FM Class 1, Div 2
Vertical
NPT
ASME 300#
304 SST
304 SST
Hastelloy
Titanium
ETFE (Tefzel)
(grounding rings not required)
Profibus PA
Battery powered
Polycarbonate
Wall-mounted
Yes
Yes
Yes
describe:
Inclined
AWWA
ASME 600#
316Ti SST
Titanium
Tantalum
Polyurethane
Profibus DP
remote signal cable length:
Full pipe?
yes
No
Foundation Fieldbus
ASME 900#
Tantalum
Cerment
Polypropylene
ASME 1500#
Platinum
Ceramic
Contact name:
Phone number:
Email address:
describe:
describe:
describe:
Minimum
Minimum
Minimum
Sp. gravity
Maximum
Maximum
Maximum
Viscosity
units:
psig°FConductivity
°C
barg
µMhos
page 1 of 2
Schedule:
Material:
OPTIFLUX 1000 OPTIFLUX 2000 OPTIFLUX 4000 OPTIFLUX 6000
The economical Solution
Water and wastewater meter
Solution for the process industry Food and pharmaceutical
OPTIFLUX 5000/7000
TIDALFLUX
WATERFLUX
Ceramic liner with For partially filled pipelines
Battery-powered water meter
non-wetted electrodes
Excellent chemical resistance
Signal converter/ transmitter types Communications protocol Out-of-Spec Diagnostics
• Integral/compact-mounted • HART • accuracy test
• Field-mounted
• Foundation Fieldbus
• gas bubbles
• Wall-mounted • RS485 Modbus • liner damage
• Rack-mounted
• Profibus PA or DP
• low conductivity
• electrode corrosion, deposit on electrodes
• short circuit
• external magnetic fields
• partial filling of measuring tube
KROHNE Electromagnetic Flowmeters
Documentation (QA/QC)
KROHNE standard (IOM + calibration certificate)
General arrangement drawing
Construction drawing (GA) for approval
Material certificates
Positive material identification (PMI)
Notes/ comments:
Test report including pressure test
Radiographic examination (RT)
Liquid (dye) penetrant examination (PT)
Welding book (WPQ, WPS & PQR)
Certificate of compliance
Inspection certificate
Inspection & test plan
Detailed production planning
page 2 of 2
Loading...