KITCHENAID KEWS175SSS, KEWS175SPA, KEWS145SSS, KEWS145SPA, KEWS105SSS Installation Instructions

...

INSTALLATION INSTRUCTIONS

24" (61 CM), 27" (68.6 CM), AND 30" (76.2 CM) INDOOR/OUTDOOR ELECTRIC WARMING DRAWER

INSTRUCTIONS D'INSTALLATION

TIROIR-RÉCHAUD ÉLECTRIQUE POUR USAGE

INTÉRIEUR/EXTÉRIEUR DE

24" (61 CM), 27" (68,6 CM), ET 30" (76,2 CM)

Table of Contents/Table des matières

WARMING DRAWER SAFETY ........................

1

SÉCURITÉ DU TIROIR-RÉCHAUD .................

5

INSTALLATION REQUIREMENTS..................

2

EXIGENCES D'INSTALLATION.......................

6

Tools and Parts..............................................

2

Outillage et pièces .........................................

6

Location Requirements .................................

2

Exigences d'emplacement ............................

6

Electrical Requirements.................................

3

Spécifications électriques..............................

7

INSTALLATION INSTRUCTIONS....................

4

INSTRUCTIONS D'INSTALLATION ................

8

Install Warming Drawer .................................

4

Installation du tiroir-réchaud..........................

8

Complete Installation.....................................

4

Achever l'installation......................................

8

WARMING DRAWER SAFETY

Your safety and the safety of others are very important.

We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.

This is the safety alert symbol.

This symbol alerts you to potential hazards that can kill or hurt you and others.

All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.” These words mean:

DANGER

WARNING

You can be killed or seriously injured if you don't immediately follow instructions.

You can be killed or seriously injured if you don't follow instructions.

All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.

IMPORTANT:

Save for local electrical inspector's use.

IMPORTANT :

À conserver pour consultation par l'inspecteur local des installations électriques.

9763140B

INSTALLATION REQUIREMENTS

Tools and Parts

Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.

Tools needed

Phillips screwdriver

Hand or electric drill

1³⁄ " (3.5 cm) hole saw

Parts supplied

Two #8–18 x ⁄ " screws

Lens (for panel ready models)

Check local codes. Check existing electrical supply. See “Electrical Requirements.”

It is recommended that all electrical connections be made by a licensed, qualified electrical installer.

Location Requirements

IMPORTANT: Observe all governing codes and ordinances.

Cutout dimensions that are shown must be used. Given dimensions provide minimum clearance with warming drawer.

Recessed installation area must provide complete enclosure around the recessed portion of the warming drawer.

Grounded electrical supply is required. See “Electrical Requirements” section.

Electrical supply outlet should be located in the rear wall on the upper right-hand side of the cutout or in an adjacent cabinet. The outlet must be recessed. If the electrical outlet is located in an adjacent cabinet, a 1³⁄ " (3.5 cm) minimum diameter hole should have been drilled in the back of the cutout or support surface to pass the power supply cord through to the outlet.

Warming drawer support surface must be solid, level and flush with bottom of cabinet cutout.

For best performance results make sure the warming drawer is leveled before completing installation. There is no way to level the warming drawer after it has been installed. If the installation is not level, the door may slide open or not seal tightly, allowing heat to escape.

Product Dimensions

B

C

A

WARMING

OVERALL

RECESSED

RECESSED

DRAWER

WIDTH (A)

WIDTH (B)

HEIGHT (C)

SIZE

 

 

 

 

 

 

 

24"

23³⁄ "

22¹⁄ "

9"

(61 cm)

(60.3 cm)

(56.5 cm)

(22.9 cm)

 

 

 

 

27"

26³⁄ "

25¹⁄ "

9"

(68.6 cm)

(67.9 cm)

(64.1 cm)

(22.9 cm)

 

 

 

 

30"

29³⁄ "

28¹⁄ "

9"

(76.2 cm)

(75.6 cm)

(71.8 cm)

(22.9 cm)

Cabinet Dimensions

Cabinet Side View

Warming

 

 

 

 

 

 

 

 

 

Support surface must be

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

drawer

 

 

 

 

 

 

 

 

 

solid, level, flush with

front

 

 

 

 

 

 

 

 

 

bottom of cabinet cutout.

 

 

 

 

 

22³⁄"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(57.8 cm)

 

 

 

 

 

 

 

 

 

 

 

 

recessed

 

 

 

 

 

 

 

 

 

oven depth

 

 

 

 

 

 

 

24"

 

 

 

 

 

 

 

 

 

 

(61 cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

min. cutout

 

 

 

 

 

 

 

 

 

 

 

depth

2

KITCHENAID KEWS175SSS, KEWS175SPA, KEWS145SSS, KEWS145SPA, KEWS105SSS Installation Instructions

Cabinet Front View

Electrical Requirements

120 volt grounded outlet

(or located in adjacent cabinet)

 

 

 

 

 

 

 

 

2¹/ " (6.4 cm) min.

 

 

 

 

 

 

 

 

 

 

cm)

Warming

 

 

 

 

 

 

9¹/ " (23.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

drawer

 

 

 

 

 

 

2¹/ " (6.4 cm) min.

cutouts

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

cm)

 

 

 

 

 

 

 

 

9¹/ " (23.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Recommended 4¹/ " (10.8 cm)

 

 

 

 

 

 

 

 

 

Toe

 

 

 

 

 

 

 

Minimum 1" (2.5 cm)

kick

 

 

 

 

 

 

4" (10.2 cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WARMING

CUTOUT

 

MIN. CABINET

DRAWER SIZE

WIDTH (A)

 

WIDTH (B)

 

 

 

 

 

 

 

 

 

 

 

 

24" (61 cm)

22¹⁄ " (57.1 cm)

 

24" (61 cm)

 

 

 

 

 

 

 

 

 

 

 

 

27" (68.6 cm)

25¹⁄ " (64.8 cm)

 

27" (68.6 cm)

 

 

 

 

 

 

 

 

 

 

 

 

30" (76.2 cm)

28¹⁄ " (72.4 cm)

 

30" (76.2 cm)

 

 

 

 

 

 

 

 

 

 

 

 

Warming drawer can be installed as an indoor single or double installation or installed under a single oven. Two warming drawers under a single oven are shown.

NOTE: The warming drawer cannot be leveled after being installed.

For outdoor installation follow the cutout dimensions above. Install the outdoor warming drawer in a permanent fixture.

Custom Wood Drawer Front

If you plan to install a custom wood panel to match your cabinets, we recommend consulting a qualified cabinetmaker or carpenter. The back of the wood panel must be sealed to avoid moisture damage.

WARNING

Electrical Shock Hazard

Plug into a grounded 3 prong outlet.

Do not remove ground prong.

Do not use an adapter.

Do not use an extension cord.

Failure to follow these instructions can result in death, fire, or electrical shock.

IMPORTANT: The warming drawer must be electrically grounded in accordance with local codes and ordinances, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1.

If codes permit and a separate ground wire is used, it is recommended that a qualified electrical installer determine that the ground path is adequate.

A copy of the above code standards can be obtained from:

National Fire Protection Association One Batterymarch Park

Quincy, MA 02269

CSA International

8501 East Pleasant Valley Road Cleveland, OH 44131-5575

A 120 volt, 60 Hz., AC only, 15-amp fused, electrical circuit is required. A time-delay fuse or circuit breaker is also recommended. It is recommended that a separate circuit serving only this warming drawer be provided.

The model/serial rating plate is located above the left-hand side receiving slide. The warming drawer must be removed to view the model/serial rating plate. See the illustration below.

A

A. Model/serial number plate

3

Loading...
+ 5 hidden pages