The MECHANISM OPERATION DESCRIPTION is the same as model KDC-S3007 and KDC-5050RG.
Please refer to the service manual for model KDC-S3007(B51-7029-00) or KDC-5050RG(B51-7099-00).
1P120/RTP0CHCON1OChanger 1 controlActive: Hi
2P121/RTP1CH_MUTEIChanger muting inputMUTE Requested : Hi
3P122/RTP2REQHOHandshake request to changersActive: Lo
4P123/RTP3ILL_ONOIllumination outputActive: Hi
5P124/RTP4NCOOpen
6P125/RTP5CD_SW2I12cm DISC detectionON: Lo
7P126/RTP6CD_SW1ILoading detectionON: Lo
8P127/RTP7NCOOpen
9VddVdd-Positive power supply
10X2X2-Main clock connection
11X1X1-Main clock connection
12VssVss-GND
13XT2XT2-Sub clock connection
14XT1XT1-Sub clock connection
15RESETRESETIReset inputActive: Lo
16P00/INTP0CH_RSTOChanger reset outputActive: Lo
17P01/INTP1R_CLKIRDS clock input
18P02/INTP2/NMIREQCIHandshake request from changerActive: Lo
19P03/INTP3NCI/O
20P04/INTP4NCI/O
21P05/INTP5NCI/O
22P06/INTP6SC_REQIHandshake request from panel µ-com
23AVddAVdd-A/D analog power supply
24AVref0AVref-A/D reference voltage input
25P10/AN10PHONEIPHONE detection terminal1V or less: PHONE
2.5V or more: NAVI MUTE
26P11/ANI1SRM_SW1ISRM position detectionOpen: Hi
27P12/ANI2NOISEIFM noise detectionAnalog input
28P13/ANI3SMETERIFM signal meter detectionAnalog input
29P14/ANI4IF_MODEIK2I IF selectorWide: Hi/Narrow: Lo
30P15/ANI5NCIGND
31P16/ANI6M_MUTE_RIMute request from mechanismMute requested: Lo
32P17/ANI7M_MUTE_LIMute request from mechanismMute requested: Lo
33AVssAVss-A/D GND
34P130/ANO0EXT_AMPOEXT_AMP control
35P131/ANO1M_RSTOReset output to mechanismReset: Lo
36AVref1-D/A reference voltage input
37P70/RxD2/SI2DATACIData line from changer
38P71/TxD2/SO2DATAHOData line to changer
39P72/ASCK2/SCK2CH_CLKI/OClock line from/to changer
40P20/RxD1/SI1
41P21/TxD1/SO1
42P22/ASCK1/SCK1L_CLK/MC_CLKI/OClock line to LCD driver
43P23/PCLM_STOPOStop request to mechanismStop requested: Lo
44P24/BUZBEEPOBeep outputActive: Hi
45P25/SI0PLL_CEOCE output to PLL
46P26/SO0PLL_DATAI/OData in/out with PLL
47P27/SCK0PLL_CLKOClock output to PLL
48P80/A0CD_SW3ISwitch detectionON : Hi
49P81/A1LO/EJOLoading/Eject controlLoading: Lo/Eject: Hi
50P82/A2MOSWOMotor outputLoading: Hi/Eject: Lo
51P83/A3MECH_ DETIMechanism detectionON: Hi/OFF: Lo
52P84/A4PAN5VOPanel detectionOFF: Hi
53P85/A5L_CE/P_RSTOCE to LCD driver/Panel µ-com reset
54P86/A6L_INH/MC_REQOReset to LCD driver
55P87/A7DIM_CONODIM control
56P40/AD0QUALIRDS receiving conditionGood: Hi
57P41/AD1R_DATAIRDS data input
58P42/AD2SRM_SUB-OSRM sub motor output
59P43/AD3SRM_SUB+OSRM sub motor output
60P44/AD4SRM_DETISRM mechanism detectionON: Lo/OFF: Hi
61P45/AD5SRM_SW2ISRM eject detection : Eject
62P46/AD6FM_SDIFM SD inputStation detected: Hi
Not detected: Lo
63P47/AD7NCOOpen
64P50/A8AFCONoise detection time constant switchingDuring reception: Hi
During search: Lo
65P51/A9O
66P52/A10WIDEOK2I Wide outputActive: Hi
67P53/A11NARROWI/OK2I Narrow outputActive: Hi
68P54/A12AM+BOAM power supplyActive: Hi
69P55/A13FM+BOFM power supplyActive: Hi
70P56/A14NCOOpen
71P57/A15NCOOpen
72Vss-GND
73P60/A16TYPE0IDestination type switch
74P61/A17TYPE1IDestination type switch
75P62/A18TYPE2IDestination type switch
76P63/A19ST_TYPE0IIC2 Var. 3 destination type 0Initial value: Lo
77P64/RDST_TYPE1IIC2 Var. 3 destination type 1Initial value: Lo
78P65/WRNCOOpen
79P66/WAITPRE MUTE ROOpenActive: Lo
80P67/ASTBPRE MUTE LOOpenActive: Lo
81Vdd-Positive power supply
82P100/TI5/TO5NCOOpen
83P101/TI6/TO6SVROPower IC resetPower ON: Lo
84P102/TI7/TO7NCOOpen
85P103/TI8/TO8P_MUTEOPower IC mutingActive: Lo
86P30/TO0ANT_CONOAntenna controlActive: Hi
87P31/TO1IC2_SCKOIC2, IC5, EEPROM clock line
88P32/TO2DIMMERIDimmer detectionActive: Lo
89P33/TI1P_CONOPower controlActive: Hi
90P34/TI2ACC_DETIACC detectionACC OFF: Hi
91P35/TI00REMOIRemote control input
92P36/TI01P_ONOµ-com peripheral power supplyActive: Hi
93P37BU_DETIMomentary power down detectionMomentary power down: Hi
94TEST-TestGND
95P90IC2_SDAI/OIC2, IC5, EEPROM data line
96P91MUTEOMuting outputActive: Hi
97P92SW5O5V power supplyActive: Lo
98P93MS_CLOCD mechanism clock line
99P94MS_DAI/OCD mechanism data line
100 P95ONC
4
TEST MODE
1.Entering the test mode
Reset the unit by pressing the FM key and the Preset 6 key
at the same time.
When the test mode is entered, all indicators light up.
2.Releasing the test mode
Reset the unit by pressing the Preset 6 key.
Note: The unit cannot be reset by simply turning ACC off,
turning power off, or turning power off for a brief
moment.
3.Voltage adjustment on the FM S-meter
(1) Enter the test mode.
(2) While pressing the Preset 1 key, keep on pressing the
Preset 6 key.
(3) When the adjustment is made, "ADJ OK" is displayed.
When adjustment cannot be made, "ADJ NG" is
displayed.
4.Writing SD voltage for the AM
(1) Enter the test mode.
(2) While pressing the Preset 1 key, keep on pressing the
Preset 6 key, which results in writing SD.
5.Forced switching of K2I Auto/Manual
In tuner-mode, keeping on pressing TI key, and the Auto
and Manual modes can be swieched. The initial condition
is manual modes, which is indicated by flashing DUAL dots.
6.Forced narrow/wide switchng of K2I
In tuner-mode, when Preset 6 is pressed, forced narrow/
wide mode switching is made. The initial condition is in wide
mode and the NEWS dot flashes.
7.CD receiver test mode specification
By pressing the track-up key, the unit jumps to the following
tracks:
No. 9 ➔ No. 15 ➔ No. 10 ➔ No. 11 ➔ No. 12 ➔ No. 13 ➔
No. 14 ➔ No. 9 (Goes back to the first position.)
When the track-down key is pressed, the unit jumps to the
previous track.
9.Tape test mode
In the initial step, the blank skip is turned off.
10.Audio-related items
• The volume is -10dB (on display, it is 30).
• The loudness is off and CRSC is off regardless of
functions.
• Buss/treble and balance/fader are to be adjusted by the
up/down key to full-boost/fullcut and fullfront/fullrear
respectively.
• The high-pass filter is adjusted by the up-key to
throughput/100Hz/200Hz and, by the down-key, to
200Hz/100Hz/throughput.
• Other adjustments are the same as before.
11.Backup current measurement
When reset in ACC-off condition (backup is on), the mute
terminal goes off after 2 seconds instead of 15 seconds,
when the ACC is tuned off in the test mode. (In this case,
the panel/CD/C/MD mechanisms are not activated.)
12.Registering security code after changing
E2PROM at the services (Only for type
M. However, RDS models are excluded)
(1) Put the unit into the test mode (Refer to 1. Above for
how to enter the test mode.)
(2) Press SRC key to put the unit into the tuner mode.
(3) Press Audio key for one second and put the unit into
the menu mode.
(4) Press FM/AM key and then select "SECURITY."
(5) Press track up/down key for full 2 seconds.
(6) Press Preset 1, Preset 2, Preset 3, and Preset 4 and
then input codes.
Example: Inputting "3510."
• Preset 1 key 4 times.
• Preset 2 key 6 times.
• Preset 3 key 2 times.
• Preset 4 key once.
(7) Press DISP key for 3 seconds and confirm that
"APPROVED" is displayed.
(8) Release the test mode. (Refer to "2. Releasing the test
mode" above.)
8.MD test mode specification
After loading MD, the unit plays No. 7. Then, the unit jumps
as follows each time it track-ups.
No. 2 ➔ No. 13 ➔ No. 23 ➔ No. 30 ➔ No. 34 ➔
No. 7 (Goes back to the first position.)
When the track-down key is pressed, the unit jumps to the
previous track.
13.Simplified method for clearing the
security code (Only for type K)
(1) When code is requested, continue pressing VOL UP
key for three seconds while pressing the DISP key.
(.... disappear.)
(2) Input "KCAR," using the remote controller (the same
as the 98 Model)
• Press Tenkey 5 twice and then press track-up key.
(Inputting "K")
• Press Tenkey 2 three times and then press track-up
key. (Inputting "C")
• Press Tenkey 2 once and then press track-up key.
(Inputting "A")
• Press Tenkey 7 twice and then press track-up key.
(Inputting "R")
(3) Then, the security is released and the unit goes into
the Tuner Mode.
14.Writing MASK KEY on line (E2PROM in
initial codition)
(1) While pressing the FM key and Preset 6 key, press
reset key to enter the test mode.
(2) Press AUDIO key for full one second to put the unit
into the menu mode.
(3) Select the "MASK KEY," using the
(4)
Press on the track up/down key to display "TRANSMIT 1."
(5) Point the MASK KEY to the light receptor and press it
for 0.5 second or longer.
(6) When "TRANSMIT 2" is displayed, press MASK KEY
for 0.5 second or longer. When this is conducted, the
counter codes for the first time and the second time
will not be compared.
(7) When "APPROVED" is displayed, writing is completed.
Time the demonstration mode is set and the test mode
is released.
Note: After an elapse of 30-minuite period, during
which no code is written, an error is effected
and the device will power off.
15.
Releasing MASK KEY requests (When
FM key or AM
key.
reset or backup is off when MASK KEY is
approved)
(1) When power is turned on, "TRANSMIT 1" is displayed
and the unit goes into MASK KEY request mode.
(2)
Point the MASK KEY to the light receptor and press it for
more than 3 seconds (until the level display indicates full)
(3) When "TRANSMIT 2" is displayed, press the MASK
KEY again for more than three seconds. At this point,
when "TRANSMIT 1" is displayed, repeat the process
in (2) above for the second time.
(4) When "APPROVED" is displayed, MASK KEY is
approved and the unit turns power on.
16.
Initializing MASK KEY (returning to the
default condition from MASK KEY
approved state)
(1) While pressing the FM key and Preset 6 key at the
same time, press RESET to enter the test mode.
(2) "TRANSMIT 1" is displayed and the unit goes into
MASK KEY request mode. The display at this point will
be "**" instead of "[ ]".
(3) Use MASK KEY release remote controller for more than
three seconds.
(4) When "TRANSMIT 2" is displayed, press the MASK
KEY for more than three seconds for the second time.
(5)
When "APPROVED" is displayed, the MASK KEY is
released and the demonstration mode is set. Then, the test
mode is released, returning the unit into default condition.
17.Clearing from the MASK KEY
(1) While pressing FM key and Preset 6 key at the same
time, press RESET to enter the test mode.
(2) Press the AUDIO key for full one second to put the unit
into the menu mode.
(3) Select MASK KEY, using track up/down key.
(4) Press on the FM key or AM key for full two seconds
and the unit will display "TRANSMIT 1."
(5) Point the MASK KEY release controller to the light
receptor and press it for 3 seconds or longer. (Until the
level display indicates full.)
(6) When "TRANSMIT 2" is displayed, press MASK KEY
for 3 seconds or longer for the second time. If
"TRANSMIT 1" is displayed, start again from (5) above.
(7)
When "APROVED" is displayed, E2PROM is cleared.
The unit goes back to the condition described in Line
14: Writing MASK KEY on line (E2PROM in initial
condition)
18.Other
• Automatic panel closing does not occur in case a TAPE,
CD, or MD is inserted.
• Panel is opened/closed when ATT key is turned On/Off.
(A remote controller is used when turning ATT on.)
• The DNPP/SBF key of the remote controller (RC-510) is
used for tuning the menu mode On/Off.
• The OPEN/CLOSE key of the remote controller (RC-510)
is used for tuning the audio mode On/Off.
• The feed on the menu will be feeds only for necessary
features.
• "CODE OFF" and other displays will not be issued when
the power is turned on.
•
The dimmer of the FL model and contrast on the LCD model
can be adjusted only for 0/5/10 by the UP/DOWN key.
6
KDC-X915/X815/PS9016R/PS9080R
KDC-PS9016R/PS9080R
ADJUSTMENT
Set the controls and switches as follows.
BALANCE: center positionBASS: center positionLOUD: OFFDOLBY NR: OFF
FADER: center positionTREBLE: center position