JULABO SC 10000w User Manual

0 (0)

Operating Manual

SemiChill Recirculating Coolers

Eco-Serie

ES

SC 5000a air cooled

SC 5000w water cooled

SC 10000w water cooled

SC 10000

 

JULABO GmbH

 

 

 

 

 

 

77960 Seelbach / Germany

 

 

Tel.

+49 (0) 7823

/ 51-0

 

 

Fax

+49 (0) 7823

/ 24 91

 

1.951.4555-V3

10/13

info@julabo.de

www.julabo.de

19514555-V3.doc

 

09.10.13

Congratulations!

You have made an excellent choice.

JULABO thanks you for the trust you have placed in us.

This operating manual has been designed to help you gain an understanding of the operation and possible applications of our circulators. For optimal utilization of all functions, we recommend that you thoroughly study this manual prior to beginning operation.

The JULABO Quality Management System

Temperature control devices for research and industry are developed, produced, and distributed according to the requirements of ISO 9001 and ISO 14001. Certificate Registration No. 01 100044846

Unpacking and inspecting

Unpack the circulator and accessories and inspect them for possible transport damage. Damage should be reported to the responsible carrier, railway, or postal authority, and a damage report should be requested. These instructions must be followed fully for us to guarantee our full support of your claim for protecting against loss from concealed damage. The form required for filing such a claim will be provided by the carrier.

Printed in Germany

Changes without prior notification reserved

Important: keep operating manual for future use

2

 

 

 

 

Recirculating Cooler

TABLE OF CONTENTS

 

Operating manual..................................................................................................................

5

1.

Intended use...................................................................................................................

5

1.1.

Description .................................................................................................................

5

2.

Operator responsibility – Safety instructions ..................................................................

5

2.1.

Disposal .....................................................................................................................

7

2.2. EC Declaration of Conformity ....................................................................................

8

2.3.

Warranty conditions ...................................................................................................

9

2.4.

Technical specifications ...........................................................................................

10

2.5.

Cooling water connection.........................................................................................

14

Operating instructions .........................................................................................................

15

3.

Operating controls and functional elements .................................................................

15

4.

Safety notes for the user ..............................................................................................

17

4.1. Explanation of safety notes......................................................................................

17

4.2. Explanation of other notes .......................................................................................

17

4.3.

Safety instructions....................................................................................................

18

5.

Preparations .................................................................................................................

20

5.1.

Installation................................................................................................................

20

5.2. Connecting the external system...............................................................................

21

 

5.2.1.Tubing .................................................................................................................

22

 

5.2.2.Bath fluids............................................................................................................

22

5.3.

Filling........................................................................................................................

23

5.4.

Draining....................................................................................................................

24

6.

Operating procedures...................................................................................................

25

6.1.

Power connection ....................................................................................................

25

6.2. Switching on / Start - Stop .......................................................................................

25

6.3. AUTOSTART ON / OFF...........................................................................................

26

7.

 

Setting the temperatures ....................................................................................

27

8.

 

Safety installations, warning functions................................................................

27

8.1.

Excess temperature protection ................................................................................

27

8.2. Early warning system, low level protection ..............................................................

28

8.3. High and low temperature warning functions...........................................................

29

8.4.

Limitation of the operating temperature range .........................................................

30

3

8.5.

Change-over of the warning function to shutdown function ......................................

31

9.

 

Menu functions ....................................................................................................

32

9.1.

Setting the pump pressure........................................................................................

33

9.2.

ATC Absolute Temperature Calibration, 3-point calibration......................................

33

9.3.

Remote control: activate – deactivate.......................................................................

36

9.4.

Interface - Baud rate, Handshake, Parity..................................................................

36

9.5.

Control parameters – Xp, Tv, Tn...............................................................................

37

9.6.

Reset.........................................................................................................................

39

10.

Troubleshooting guide / Error messages.......................................................................

39

11.

Electrical connections....................................................................................................

41

12.

Remote control ..............................................................................................................

42

12.1. Setup for remote control ...........................................................................................

42

12.2. Communication with a PC or a superordinated data system ....................................

42

12.3. List of commands......................................................................................................

43

12.4. Status messages ......................................................................................................

45

12.5. Error messages.........................................................................................................

45

13.

JULABO Service – Online remote diagnosis.................................................................

46

14.

Cleaning / repairing the unit...........................................................................................

47

4

Recirculating Cooler

Operating manual

1.Intended use

JULABO recirculating coolers have been designed to control the temperature of specific fluids in a bath tank. The units feature pump connections for temperature control of external systems (loop circuit).

JULABO recirculating coolers are not suitable for direct temperature control of foods, semi-luxury foods and tobacco, or pharmaceutical and medical products. Direct temperature control means unprotected contact of the object with the bath medium (bath fluid).

1.1.Description

PID2

ATC3

RS232

SMART

PUMP

The recirculating coolers are operated via the splash-proof keypad. The implemented microprocessor technology allows to set and to store different values that can be indicated on the MULTI-DISPLAY (LED). Three menu keys facilitate adjusting setpoints, warning and safety functions and menu functions.

The PID temperature control adapts the heat supplied to the thermal requirements of the bath.

Absolute Temperature Calibration (ATC3) provides a high temperature stability in the bath. With the 3-point calibration an offset is adjusted at three temperatures to ensure an accurate temperature pattern at the selected spot in the bath over the full temperature range.

Electrical connections:

The serial interface RS232 allows modern process technology without additional interface.

The excess temperature protection conforming to IEC 61010-2-010 is a safety installation independent from the control circuit. This protection can be indicated and set on the MULTI-DISPLAY (LED).

The early warning system for low level signals that bath fluid needs to be refilled before the low level protection conforming to IEC 61010-2-010 causes a complete shut-down of the main functional elements.

The pump capacity (electronically adjustable via the motor speed) enables to adapt to varying conditions for internal and external temperature applications.

2.Operator responsibility – Safety instructions

The products of JULABO ensure safe operation when installed, operated, and maintained according to common safety regulations. This section explains the potential dangers that may arise when operating the circulator and also specifies the most important safety precautions to preclude these dangers as far as possible.

The operator is responsible for the qualification of the personnel operating the units.

5

Operator responsibility – Safety instructions

The personnel operating the units should be regularly instructed about the dangers involved with their job activities as well as measures to avert these dangers.

Make sure all persons tasked with operating, installing, and maintaining the unit have read and understand the safety information and operating instructions.

When using hazardous materials or materials that could become hazardous, the circulator may be operated only by persons who are absolutely familiar with these materials and the circulator. These persons must be fully aware of possible risks.

If you have any questions concerning the operation of your unit or the information in this manual, please contact us!

Contact:

JULABO GmbH

Tel.

+49 (0) 7823

/ 51-0

info@julabo.de

 

Eisenbahnstraße 45

Fax

+49 (0) 7823

/ 24 91

www.julabo.de

 

77960 Seelbach / Germany

 

 

 

 

 

Safety instructions for the operator:

Avoid strikes to the housing, vibrations, damage to the operating-element panel (keypad, display), and contamination.

Make sure the product is checked for proper condition regularly (depending on the conditions of use). Regularly check (at least every 2 years) the proper condition of the mandatory, warning, prohibition and safety labels.

Make sure that the mains power supply has low impedance to avoid any negative effects on the instruments being operated on the same mains.

This unit is designed for operation in a controlled electromagnetic environment. This means that transmitting devices (e.g., cellular phones) should not be used in the immediate vicinity.

Magnetic radiation may affect other devices with components sensitive to magnetic fields (e.g., monitors). We recommend maintaining a minimum distance of 1 m.

Permissible ambient temperature: max. 40 °C, min. 5 °C.

Permissible relative humidity: 50% (40 °C).

Do not store the unit in an aggressive atmosphere. Protect the unit from contamination.

Do not expose the unit to sunlight.

Appropriate operation

Only qualified personnel is authorized to configure, install, maintain, or repair the circulator.

Persons who operate the circulator must be trained in the particular tasks by qualified personnel. The summarized user guidance (short manual) and the specification table with information on individual parameters are sufficient for this.

Use

The bath can be filled with flammable materials. Fire hazard!

There might be chemical dangers depending on the bath medium used.

Observe all warnings for the used materials (bath fluids) and the respective instructions (safety data sheets).

Insufficient ventilation may result in the formation of explosive mixtures. Only use the unit in well ventilated areas.

Only use recommended materials (bath fluids). Only use non-acid and non corroding materials.

6

Recirculating Cooler

When using hazardous materials or materials that could become hazardous, the operator must affix the enclosed safety labels (1 + 2) to the front of the unit so they are highly visible:

1

Warning label W00: Colors: yellow, black

 

Danger area. Attention! Observe instructions.

 

(operating manual, safety data sheet)

 

 

 

2

Mandatory label M018:

Colors: blue, white

Carefully read the user information prior to beginning operation.

Scope: EU

or

2 Semi S1-0701 Table A1-2 #9

Carefully read the user information prior to beginning operation.

Scope: USA, NAFTA

Particular care and attention is necessary because of the wide operating range.

There are thermal dangers: Burn, scald, hot steam, hot parts and surfaces that can be touched. Warning label W26: Colors: yellow, black

Hot surface warning.

(The label is put on by JULABO)

Observe the instructions in the manuals for instruments of a different make that you connect to the circulator, particularly the corresponding safety instructions. Also observe the pin assignment of plugs and technical specifications of the products.

2.1.Disposal

The recirculating cooler contains a back-up battery that supplies voltage to the memory chips when the unit is switched off. Do not dispose of the battery with household waste!

Depending on battery regulations in your country, you may be obligated to return used or defective batteries to collection sites.

The product may be used with oil as bath fluid. These oils fully or partially consist of mineral oil or synthetic oil. For disposal, follow the instructions in the material safety data sheets.

This unit contains the refrigerant R404A, which at this time is not considered harmful to the ozone layer. However, over the long operating period of the unit, disposal rules may change. Therefore, only qualified personnel should handle the disposal.

Valid in EU countries

See the current official journal of the European Union – WEEE directive. Directive of the European Parliament and of the Council on waste electrical and electronic equipment (WEEE).

This directive requires electrical and electronic equipment marked with a crossedout trash can to be disposed of separately in an environmentally friendly manner. Contact an authorized waste management company in your country.

Disposal with household waste (unsorted waste) or similar collections of municipal waste is not permitted!

7

JULABO SC 10000w User Manual

Operator responsibility – Safety instructions

2.2.EC Declaration of Conformity

8

Recirculating Cooler

2.3.Warranty conditions

JULABO GmbH warrants its products against defects in material or in workmanship, when used under appropriate conditions and in accordance with appropriate operating instructions

for a period of ONE YEAR.

Extension of the warranty period – free of charge

With the ‘1PLUS warranty’ the user receives a free of charge extension to the warranty of up to 24 months, limited to a maximum of 10 000 working hours.

To apply for this extended warranty the user must register the unit on the JULABO web site www.julabo.de, indicating the serial no. The extended warranty will apply from the date of JULABO GmbH’s original invoice.

JULABO GmbH reserves the right to decide the validity of any warranty claim. In case of faults arising either due to faulty materials or workmanship, parts will be repaired or replaced free of charge, or a new replacement unit will be supplied.

Any other compensation claims are excluded from this guarantee.

9

Operator responsibility – Safety instructions

2.4.Technical specifications

EcoSeries

 

 

 

 

SC 5000a

 

SC 5000w

 

Working temperature ranges:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Standard unit

 

 

 

°C

+5 ... +35

 

+5 ... +35

 

Option

Low Temp

 

 

°C

-20 ... +35

 

-20 ... +35

 

 

 

 

 

 

 

 

 

Option

Low /HighTemp I

 

°C

-20 ... +80

 

-20 ... +80

 

Option

Low /HighTemp II

 

°C

-20 ... +130

 

-20 ... +130

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Temperature stability

 

 

°C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Absolute Temperature Calibration

 

 

0.1

 

 

0.1

 

 

 

 

 

 

 

 

±3

 

 

±3

 

 

 

 

 

 

 

 

 

 

 

Heater wattage (at 230 V) Option H5

 

kW

5.0

 

 

5.0

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling capacity

 

 

 

°C

+20

0

-10

+20

0

-10

Medium ethanol

 

 

 

kW

5.0

2.5

1.2

5.0

2.5

1.2

 

 

 

 

 

 

 

 

 

 

Refrigerant

 

 

 

 

R404A

 

 

R404A

 

 

 

 

 

 

 

 

 

Pump capacity P3 (Standard) / P4 * (Option)

 

 

 

 

 

 

 

see table 1 page 12

 

 

 

 

 

 

 

 

 

Flow rate

 

P3 / P4

l/min at 0 bar

34 / 42

 

 

34 / 42

 

 

 

 

 

 

 

 

Pressure max.

P3 / P4

bar at 0 liters

3.2 / 5.2

 

3.2 / 5.2

 

 

 

 

 

 

 

 

Overall dimensions (WxDxH)

 

cm

59x67/112

 

59x67/112

 

Filling volume

 

 

 

liters

43 ... 60

 

43 ... 60

 

 

 

 

 

 

 

 

 

 

 

 

 

Weight

 

 

 

 

kg

153

 

 

153

 

 

Ambient temperature

 

 

°C

5 ... 40

 

 

5 ... 40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mains power connection

 

V/ Hz

400/50/3 phases

400/50/3 phases

 

365-440V/3PNPE/50Hz

 

 

 

 

 

 

 

 

Current consumption

without heater

 

A

11/ phase (at 400 V)

11/ phase (at 400 V)

Current consumption

with 5kW heater

A

23/ phase (at 400 V)

23/ phase (at 400 V)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mains power connection

 

V/ Hz

208-230/60/3 phases

208-230/60/3 phases

 

192-254V/3PPE/60Hz

 

 

 

 

 

 

 

 

Current consumption

without heater

 

A

20/ phase (at 230 V)

20/ phase (at 230 V)

Current consumption

5kW heater

 

A

21/ phase (at 230 V)

21/ phase (at 230 V)

 

 

 

 

 

 

 

 

 

 

 

 

All measurements have been carried out at: rated voltage and frequency ambient temperature: 20 °C Technical changes without prior notification reserved.

* Pump P4reduces cooling capacity by 0.3 kW

10

Recirculating Cooler

EcoSeries

 

 

SC 10000w

 

Working temperature ranges:

 

 

 

 

 

 

 

 

 

Standard unit

 

°C

+5 ... +35

 

Option

Low Temp

°C

-20 ... +35

 

 

 

 

 

 

Option

Low /HighTemp I

°C

-20 ... +80

 

Option

Low /HighTemp II

°C

-20 ... +130

 

 

 

 

 

 

 

 

 

 

 

 

 

Temperature stability

°C

0.1

 

 

 

 

 

 

 

Absolute Temperature Calibration

 

±3

 

 

 

 

 

 

 

Heater wattage (at 230 V) Option H5

kW

5.0

 

 

 

 

 

 

 

 

Cooling capacity

 

°C

+20

0

-10

Medium ethanol

 

kW

10

5.0

2.5

 

 

 

 

 

Refrigerant

 

 

R404A

 

 

 

 

 

Pump capacity P3 (Standard) / P4 * (Option)

 

 

 

see table 1 page 12

 

 

 

 

Flow rate

 

P3 / P4

l/min at 0 bar

33 / 43

 

 

 

 

 

 

Pressure max.

P3 / P4

bar at 0 liters

3.5 / 4.4

 

 

 

 

 

Overall dimensions (WxDxH)

cm

59x67/112

 

Filling volume

 

liters

43 ... 60

 

 

 

 

 

 

 

 

Weight

 

 

kg

159

 

 

Ambient temperature

°C

5 ... 40

 

 

 

 

 

 

 

 

 

 

 

Mains power connection

V/ Hz

400/50/3 phases

 

365-440V/3PNPE/50Hz

 

 

 

 

Current consumption without heater

A

11/ phase (at 400 V)

Current consumption 5 kW heater

A

23/ phase (at 400 V)

 

 

 

 

 

 

 

 

 

 

Mains power connection

V/ Hz

208-230/60/3 phases

 

197-254V/3PPE/60Hz

 

 

 

 

Current consumption without heater

A

19/ phase (at 208 V)

Current consumption 5 kW heater

A

23/ phase (at 230 V)

 

 

 

 

 

 

 

All measurements have been carried out at: rated voltage and frequency ambient temperature: 20 °C Technical changes without prior notification reserved.

* Pump P4reduces cooling capacity by 0.3 kW

11

Operator responsibility – Safety instructions

EcoSeries

 

 

 

 

 

Temperature selection

 

 

 

digital

 

 

 

 

 

 

 

via keypad

 

 

 

indication on LED-Multi-Display

 

remote control via personal computer

 

 

 

indication on monitor

 

 

 

 

 

 

 

Temperature indication

°C

 

 

LED-Multi-Display

 

Resolution

°C

0.1

 

 

 

 

 

 

 

Electrical connection:

Computer interface RS232

Table 1

Pump capacity

 

XX.XX

 

XX.XX

 

 

 

 

 

 

Bath fluid:

Water, Silicone -oil

PUMP

 

PUMP

 

 

 

 

1

 

2

 

Circulating pump:

 

P3

P4

P3

P4

 

 

 

 

 

Flow rate max.

Lpm at 0 bar

30

40

33

43

 

 

 

 

Pressure max.

bar at 0 liter

1.8

2.5

3.5

4.4

 

 

 

 

Bath fluid:

Galden®

 

 

 

 

eg. Fluorinert® 3283

 

 

 

 

Pressure max.

bar at 0 liter

3.5

4.4

 

 

 

 

 

 

 

 

Notice:

 

 

 

 

If Galden® or Fluorinert® is used the the charge of the motor increases. Wrong adjustment causes overheating and eventually destruction of the motor.

With the circulation pump P3 as well as P4 a maximum pump pressure stage >PUMP 1< may be adjusted.

The pump type can be recognized in the order no. on the name plate. 95 xx xxx _ xx PX xx

12

Recirculating Cooler

Safety installations according to IEC 61010-2-010:

Excess temperature protection

adjustable from 0 °C ... 320 °C

Low liquid level protection

float switch

Classification according to DIN 12876-1

class III

Supplementary safety installations

 

Early warning system for low level

float switch

High temperature warning function

optical + audible (in intervals)

Low temperature warning function

optical + audible (in intervals)

Supervision of working sensor

plausibility control

Reciprocal sensor monitoring between

 

working and safety sensors

difference >35 K

Alarm message

optical + audible (permanent)

Warning message

optical + audible (in intervals)

Environmental conditions according to IEC 61 010-1: Use indoors only.

Altitude up to 2000 m - normal zero.

Ambient temperature: see Technical specifications Humidity:

Max. relative humidity 80% for temperatures up to +31 °C,

linear decrease down to 50% relative humidity at a temperature of +40 °C Max. mains voltage fluctuations of ±10% are permissible.

Protection class according to IEC 60 529

IP21

The unit corresponds to Class I

 

Overvoltage category

II

Pollution degree

2

Caution:

The unit is not for use in explosive environment.

EMC requirements according to EN 61326-1

This unit is an ISM device classified in Group 1 (using high frequency for internal purposes), Class A (industrial and commercial range).

13

Operator responsibility – Safety instructions

2.5.Cooling water connection

Cooling water pressure (IN/OUT)

max.

6 bar

Pressure difference (IN - OUT)

 

3.5 to 6 bar

Cooling water temperature

 

 

< 20 °C

Notice:

Cooling water circuit

 

Risk of oil leaking from the refrigeration system (compressor) of the recirculating cooler into the cooling water in case of a fault in the cooling water circuit!

Observe the laws and regulations of the water distribution company valid in the location where the unit is operated.

Notice:

Danger of corrosion of heat exchanger due to unsuitable quality of cooling water.

Due to its high content of lime, hard water is not suitable for cooling and causes scale in the heat exchanger.

Ferrous water or water containing ferrous particles will cause formation of rust even in heat exchangers made of stainless steel.

Chlorinated water will cause pitting corrosion in heat exchangers made of stainless steel.

Due to their corrosive characteristics, distilled water and deionized water are unsuitable and will cause corrosion of the bath.

Due to its corrosive characteristics, sea water is not suitable.

Due to its microbiological (bacterial) components, which settle in the heat exchanger, untreated and unpurified river water and water from cooling towers is unsuitable.

Avoid particulate matter in cooling water.

Avoid putrid water.

Recommended quality of cooling water:

pH

7.5 to 9.0

Sulfate [SO4 2- ]

< 100 ppm

Hydrocarbonate [HCO 3-]/sulfate [SO4 2-]

> 1 ppm

Hardness [Ca 2+, Mg 2+]/[HCO 3-]

> 0.5 dH

Alkalinity

60 ppm < [HCO 3-] < 300 ppm

Conductivity

< 500 μS/cm

Chloride (Cl -)

< 50 ppm

Phosphate (PO4 3-)

< 2 ppm

Ammonia (NH3)

< 0.5 ppm

Free chlorine

< 0.5 ppm

Trivalent iron ions (Fe 3+)

< 0.5 ppm

Manganese ions (Mn 2+)

< 0.05 ppm

Carbon dioxide (CO2)

< 10 ppm

Hydrogen sulfide (H2S)

< 50 ppm

Content of oxygen

< 0.1 ppm

Algae growth

impermissible

Suspended solids

impermissible

14

Recirculating Cooler

Operating instructions

3.Operating controls and functional elements

Front view

 

 

 

 

 

 

Rear view

 

 

7

5

4

3

2

1

 

12

 

 

 

 

ES

 

 

 

 

 

 

 

6

 

 

 

 

 

19

OUT

IN

22

 

 

 

 

 

 

 

 

 

 

 

 

 

20

1

 

23

 

 

 

 

 

 

0

 

8

 

 

 

 

 

 

 

 

 

9

 

 

 

 

SC 10000

21

 

 

24

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

26

1

2

 

60

130

3

180

30

 

 

 

10

220

°C

4 Keypad

Mains power switch

Emergency stop switch

Adjustable excess temperature protection according to IEC 61010-2-010

Start / stop key

Key for selecting the working temperature - Setpoint 1, 2, 3 Key for selecting the warning and safety values

MENU button - for selecting the menu functions

Cursor keys (left or right)

15

Loading...
+ 33 hidden pages