1.951.0253-V2 06/13

19510253-V2.doc

Print date: 11.07.13

Congratulations!

You have made an excellent choice.

JULABO thanks you for the trust you have placed in us.

This operating manual has been designed to help you gain an understanding of the operation and possible applications of our circulators. For optimal utilization of all functions, we recommend that you thoroughly study this manual prior to beginning operation.

The JULABO Quality Management System

Temperature control devices for research and industry are developed, produced, and distributed according to the requirements of ISO 9001 and ISO 14001. Certificate Registration No. 01 100044846

Unpacking and inspecting

Unpack the circulator and accessories and inspect them for possible transport damage.

Damage should be reported to the responsible carrier, railway, or postal authority, and a damage report should be requested. These instructions must be followed fully for us to guarantee our full support of your claim for protecting against loss from concealed damage. The form required for filing such a claim will be provided by the carrier.

Printed in Germany

Changes without prior notification reserved

Important: keep operating manual for future use

2

EH

TABLE OF CONTENTS

 

Operating manual ....................................................................................................................

4

1.

Intended use....................................................................................................................

4

 

1.1. Description ..................................................................................................................

4

2.

Operator responsibility – Safety recommendations .........................................................

4

 

2.1. Disposal.......................................................................................................................

7

 

2.2. EC Conformity .............................................................................................................

8

 

2.3. Warranty conditions.....................................................................................................

8

 

2.4.

Technical specifications...............................................................................................

9

Operating instructions ............................................................................................................

13

3.

Safety notes for the user................................................................................................

13

 

3.1. Explanation of safety notes .......................................................................................

13

 

3.2. Explanation of other notes.........................................................................................

13

 

3.3. Safety recommendations...........................................................................................

13

4.

Operating controls and functional elements...................................................................

16

5.

Preparations ..................................................................................................................

18

 

5.1.

Installation .................................................................................................................

18

 

5.2.

Bath fluids..................................................................................................................

18

 

5.3.

Filling / Draining.........................................................................................................

20

 

5.4. Temperature application to external systems ............................................................

21

 

5.4.1.

Tubing...............................................................................................................

21

 

5.5. Adjusting the pump flow ............................................................................................

22

6.

Operating procedures ....................................................................................................

23

 

6.1. Power connection ......................................................................................................

23

 

6.2. Switching on / Start - Stop .........................................................................................

23

 

6.3. Automatic / non-automatic start mode .......................................................................

24

 

6.4. Setting the temperatures ...........................................................................................

25

 

6.5. ATC - Absolute Temperature Calibration...................................................................

26

 

6.6. Timer function............................................................................................................

27

 

6.6.1.

Setting the time.................................................................................................

27

 

6.6.2.

Timer operation.................................................................................................

27

 

6.7. Safety installations according to IEC 61010-2-010....................................................

28

 

6.7.1.

Excess temperature protection .........................................................................

28

 

6.7.2. Low liquid level protection.................................................................................

28

7.

Troubleshooting guide / Error messages .......................................................................

29

8.

Electrical connections ....................................................................................................

31

9.

Cleaning / repairing the unit...........................................................................................

31

3

Operating manual

Operating manual

1.Intended use

JULABO circulators have been designed to control the temperature of specific fluids in a bath tank. The units feature pump connections for temperature control of external systems (loop circuit).

JULABO circulators are not suitable for direct temperature control of foods, semi-luxury foods and tobacco, or pharmaceutical and medical products.

Direct temperature control means unprotected contact of the object with the bath medium (bath fluid).

1.1.Description

PID1

40

80

120

 

0

160

°C

The circulators are operated via the splash-proof keypad. The implemented microprocessor technology allows to set and to store the setpoint that can be indicated on the LED temperature display.

The PID temperature control adapts the heat supplied to the thermal requirements of the bath.

ATC - Absolute Temperature Calibration (1-point calibration)

Safety installations conforming to IEC 61010-2-010

The excess temperature protection is a safety installation independent from the control circuit.

The safety value is set using a tool (screwdriver).

If the low level protection device is triggered, a complete shutdown of the heater and circulating pump is effected.

Electrical connection:

Alarm output for external alarm message or control of JULABO refrigerating baths.

2.Operator responsibility – Safety recommendations

The products of JULABO ensure safe operation when installed, operated, and maintained according to common safety regulations. This section explains the potential dangers that may arise when operating the circulator and also specifies the most important safety precautions to preclude these dangers as far as possible.

The operator is responsible for the qualification of the personnel operating the units.

The personnel operating the units should be regularly instructed about the dangers involved with their job activities as well as measures to avert these dangers.

Make sure all persons tasked with operating, installing, and maintaining the unit have read and understand the safety information and operating instructions.

When using hazardous materials or materials that could become hazardous, the circulator may be operated only by persons who are absolutely familiar with these materials and the circulator. These persons must be fully aware of possible risks.

4

EH

If you have any questions concerning the operation of your unit or the information in this manual, please contact us!

Contact:

JULABO GmbH

Tel.

+49 (0)

7823 / 51-0

info@julabo.de

 

Eisenbahnstraße 45

Fax

+49 (0)

7823 / 24 91

www.julabo.de

 

77960 Seelbach / Germany

 

 

 

 

 

Safety instructions for the operator:

You have received a product designed for industrial use. Nevertheless, avoid strikes to the housing, vibrations, damage to the operating-element panel (keypad, display), and contamination.

Make sure the product is checked for proper condition regularly (depending on the conditions of use). Regularly check (at least every 2 years) the proper condition of the mandatory, warning, prohibition and safety labels.

Make sure that the mains power supply has low impedance to avoid any negative effects on instruments being operated on the same mains.

This unit is designed for operation in a controlled electromagnetic environment. This means that transmitting devices (e.g., cellular phones) should not be used in the immediate vicinity. Magnetic radiation may affect other devices with components sensitive to magnetic fields (e.g., monitors). We recommend maintaining a minimum distance of 1 m.

Permissible ambient temperature: max. 40 °C, min. 5 °C.

Permissible relative humidity: 50% (40 °C).

Do not store the unit in an aggressive atmosphere.

Protect the unit from contamination.

Do not expose the unit to sunlight.

Appropriate operation

Only qualified personnel is authorized to perform configuration, installation, maintenance and repairs of the circulator.

Routine operation can also be carried out by untrained personnel who should however be instructed by trained personnel.

Use:

The bath can be filled with flammable materials. Fire hazard!

There might be chemical dangers depending on the bath medium used.

Observe all warnings for the used materials (bath fluids) and the respective instructions (safety data sheets).

Insufficient ventilation may result in the formation of explosive mixtures. Only use the unit in well ventilated areas. The unit is not for use in explosive atmosphere.

Only use recommended materials (bath fluids). Only use non-acid and non corroding materials.

5

Operator responsibility – Safety recommendations

When using hazardous materials or materials that could become hazardous, the operator must affix the enclosed safety labels (1 + 2) to the front of the unit so they are highly visible:

1

Warning label W00:

Colors: yellow, black

 

Danger area. Attention! Observe instructions.

 

(operating manual, safety data sheet)

 

 

 

2

Mandatory label M018:

Colors: blue, white

 

Carefully read the user information prior to beginning operation.

or

Scope: EU

 

 

 

2

Semi S1-0701 Table A1-2 #9

 

Carefully read the user information prior to beginning operation.

 

Scope: USA, NAFTA

 

 

 

 

Particular care and attention is necessary because of the wide operating range.

There are thermal dangers:

Burn, scald, hot steam, hot parts and surfaces that can be touched.

Warning label W26: Colors: yellow, black

Hot surface warning.

(The label is put on by JULABO)

Observe the instructions in the manuals for instruments of a different make that you connect to the circulator, particularly the respective safety recommendations. Also observe the pin assignment of plugs and technical specifications of the products.

6

EH

2.1.Disposal

The product may be used with oil as bath fluid. These oils fully or partially consist of mineral oil or synthetic oil. For disposal, observe the instructions in the safety data sheets.

This unit contains the refrigerants R134a – at this time considered not to have any negative effects on the ozone layer. However, during the long operating period of the unit, disposal prescriptions may change. So only qualified personnel should take care of disposal.

Valid in EU countries

See the current official journal of the European Union – WEEE directive.

Directive of the European Parliament and of the Council on waste electrical and electronic equipment (WEEE).

This directive requires electrical and electronic equipment marked with a crossed-out trash can to be disposed of separately in an environmentally friendly manner.

Contact an authorized waste management company in your country.

Disposal with household waste (unsorted waste) or similar collections of municipal waste is not permitted!

7

JULABO F34-EH User Manual

Operator responsibility – Safety recommendations

2.2.EC Conformity

The products described in the operating instructions conform to the requirements of the following European guidelines:

Directive of the European Parliament and of the Council on the approximation of the laws of the Member States relating to machinery.

EMC guideline with respect to legal harmonization of the member countries concerning electromagnetic compatibility.

JULABO GmbH

Eisenbahnstr. 45

77960 Seelbach / Germany

2.3.Warranty conditions

JULABO GmbH warrants its products against defects in material or in workmanship, when used under appropriate conditions and in accordance with appropriate operating instructions

for a period of ONE YEAR.

Extension of the warranty period – free of charge

With the ‘1PLUS warranty’ the user receives a free of charge extension to the warranty of up to

24 months, limited to a maximum of 10 000 working hours.

To apply for this extended warranty the user must register the unit on the JULABO web site www.julabo.de, indicating the serial no. The extended warranty will apply from the date of JULABO GmbH’s original invoice.

JULABO GmbH reserves the right to decide the validity of any warranty claim. In case of faults arising either due to faulty materials or workmanship, parts will be repaired or replaced free of charge, or a new replacement unit will be supplied.

Any other compensation claims are excluded from this guarantee.

8

EH

2.4.Technical specifications

 

 

 

 

F12-EH

 

 

F25-EH

 

 

 

 

 

 

 

 

Working temperature range

 

°C

-20 ... 150

 

-28 ... 150

Temperature stability

 

°C

±0.03

 

±0.03

 

 

 

 

 

 

 

 

Temperature selection

 

 

 

digital

 

 

digital

Temperature indication

 

 

 

LED

 

 

LED

Resolution

 

°C

0.1

 

0.1

ATC - Absolute Temperature Calibration

 

 

1-point

 

 

1-point

Temperature control

 

 

 

PID1

 

 

PID1

 

 

 

 

 

 

 

 

Heater wattage (at 230 V)

 

kW

2.0

 

2.0

Heater wattage (at 115 V)

 

kW

1.0

 

1.0

Cooling capacity

 

°C

+20 0

-20

+20 0 -20

Medium ethanol

 

kW

0.16 0.1

0.02

0.26 0.2 0.06

Refrigerant

 

 

 

R134a

 

 

R134a

 

 

 

 

 

 

 

 

Circulating pump:

 

 

 

 

 

 

 

discharge, max.at 0 bar

 

l/min

15

 

15

pressure, max. at 0 l

 

bar

0,35

 

0,35

Electrical connections:

 

 

 

 

 

 

 

External alarm device

 

Vdc/mA

 

24-0 / max. 25

 

24-0 / max. 25

 

 

 

 

 

 

 

 

Overall dimensions (WxDxH)

 

cm

 

20x36x56

 

 

23x42x61

Bath opening (WxL)

 

cm

 

13x15

 

 

12x14

Bath depth

 

cm

13

 

14

Filling volume from ... to

 

liters

3 ... 4.5

 

3 ... 4.5

Weight

 

kg

22

 

30

Ambient temperature

 

°C

5 ... 40

 

5 ... 40

 

 

 

 

 

 

Mains power connection 230 V/50 Hz

V/ Hz

207-253 / 50

207-253 / 50

Current input (at 230 V)

 

A

11

 

12

Current input (at 230 V) CH

 

A

<9 + 1>

 

<9 + 2>

 

 

 

 

 

 

Mains power connection 230 V/60 Hz

V/ Hz

207-253 / 60

207-253 / 60

Current input (at 230 V)

 

A

11

 

12

 

 

 

 

 

 

Mains power connection 115 V/60 Hz

V/ Hz

103-127 / 60

103-127 / 60

Current input (at 115 V)

 

A

12

 

13

 

 

 

 

 

 

Mains power connection 100 V/50-60 Hz

V/ Hz

 

90-110V/50-60Hz

 

90-110V/50-60Hz

Current input (at 100 V)

 

A

 

15

 

 

13

All measurements have been carried out at: rated voltage and frequency

 

 

ambient temperature: 20 °C

Technical changes without prior notification reserved.

9

Operator responsibility – Safety recommendations

 

 

 

 

 

F32-EH

 

 

 

Working temperature range

 

°C

-35 ... 150

 

 

 

Temperature stability

 

°C

 

±0.03

 

 

 

 

 

 

 

 

 

 

 

 

Temperature selection

 

 

 

 

digital

 

 

 

Temperature indication

 

 

 

LED

 

 

 

Resolution

 

°C

 

0.1

 

 

 

ATC - Absolute Temperature Calibration

 

 

1-point

 

 

 

Temperature control

 

 

 

 

PID1

 

 

 

 

 

 

 

 

 

 

Heater wattage (at 230 V)

 

kW

 

2.0

 

 

 

Heater wattage (at 115 V)

 

kW

1.0

 

 

 

Cooling capacity

 

°C

 

+20 0

-20

 

 

Medium ethanol

 

kW

0.45 0.39 0.15

 

 

Refrigerant

 

 

 

 

R134a

 

 

 

 

 

 

 

 

 

 

 

 

Circulating pump:

 

 

 

 

 

 

 

 

discharge, max.at 0 bar

 

l/min

15

 

 

 

pressure, max. at 0 l

 

bar

 

0.35

 

 

 

Electrical connections:

 

 

 

 

 

 

 

 

External alarm device

 

Vdc/mA

 

 

24-0 / max. 25

 

 

 

 

 

 

 

 

 

 

 

Overall dimensions (WxDxH)

 

cm

 

 

31x42x64

 

 

 

Bath opening (WxL)

 

cm

 

 

18x12

 

 

 

Bath depth

 

cm

 

15

 

 

 

Filling volume from ... to

 

liters

5.5 ... 8

 

 

 

Weight

 

kg

 

36

 

 

 

Ambient temperature

 

°C

5 ... 40

 

 

 

 

 

 

 

 

 

Mains power connection 230 V/50 Hz

V/ Hz

207-253 / 50

 

 

Current input at (at 230 V)

 

A

 

12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mains power connection 230 V/60 Hz

V/ Hz

207-253 / 60

 

 

Current input at (at 230 V)

 

A

 

12

 

 

 

 

 

 

 

 

Mains power connection 115 V/60 Hz

V/ Hz

 

103-127 / 60

 

 

Current input at (at 115 V)

 

A

14

 

 

 

 

 

 

 

 

 

 

Mains power connection 100 V/50-60 Hz

V/ Hz

 

 

90-110V/50-60Hz

Current input (at 100 V)

 

A

 

14

 

 

 

All measurements have been carried out at: rated voltage and frequency

ambient temperature: 20 °C

Technical changes without prior notification reserved.