Learn Mode
™
Slim Line
Door/Window Sensor
Document Number: 46-549-01 Rev. E
November 1999
ITI Part No. 60-499
Installation Instructions
Product Summary
The Learn Mode™ Slim Line Door/Window Sensor detects
the opening of various doors, windows, and drawers. The
sensor utilizes ITI Learn Mode technology to simplify sensor programming, and contains an RF transmitter and one
magnetic reed switch.
The sensor can be used in UL Listed residential installations
with the following ITI panels and receivers: Commander
2000 (60-437), UltraGard
Concord™ (60-734, 60-792-95R), Concord Express™ (60806-95R), RF7434-ITI and RF7435-ITI (60-731), when
used in conjunction with the DS7400Xi Control/Communicator.
The sensor can also be used in UL Listed commercial
installations with the following ITI panels and receivers:
RF7434-ITI and RF7435-ITI (60-731), and Concord™ (60734, 60-792-95R), when used in conjunction with the
DS7400Xi Control/Communicator.
®
(60-650), Simon® (60-693),
How It Works
With the panel in program mode, the installer trips the sensor tamper switch by opening its cover. The sensor transmits a unique ID which the panel “learns.”
When the door or window is opened, the sensor transmits a
“TRIP” signal. When the door is closed, a “RESTORE” signal is transmitted. These signals are sent whether the system
is armed or not.
®
Guidelines
Determine the best mounting location for the sensor using
the following guidelines:
DO
❑ Try to keep all sensors within 100 feet of the panel. The
100 foot distance recommendation is given as a starting
guideline. The sens or has an o pen air range o f over 500
feet, but the installat ion environmen t will influ ence this
range. Mount sensor on door frame, magnet on door.
For double door installation mount sensor on least used
door, magnet on other.
❑ Mount sensors with screws, not double sided tape.
DO NOT
❑ Place sensors on a door within 5 in. of the floor to
avoid damage to the sensors.
❑ Place sensors or magnets on any metallic surface such
as metal doors or foil wallpaper.
❑ Place sensors in areas wit h excessive me tal or electr ical
wiring, such as furnace/utility rooms.
❑ Place sensors in areas where they will be exposed to
moisture. Sensors are for indoor use only.
❑ Place sensors in locations where the temperature will
exceed sensor operating limits of 10 to 120° F.
❑ Place sensors or magnets where they will interfere with
door or window opening.
Mounting the Sensor
The sensor transmits a supervisory signal every 64 minutes.
When the sensor battery voltage is low, a low battery (trouble) signal is sent to the panel. The sensor has an estimated
battery life of 3 to 5 years (ba ttery life not verified by UL).
Tools Needed
❑ Small Phillips Screwdriver
❑ Two #6 Pan Head Screws
❑ T wo #6 x 1/2 in. Pan Head Scr ews or Two #18 x 1/2 in.
Wire Nails
1. Remove the sensor cover by pressing on the cover
release catch. This releas es the tab on the ba se from the
slot in the sensor cover (see Figure 1).
Cover Release
Catch
Figure 1. Removing the Sensor Cover
1
Learn Mode Slim Line Door/Window Sensor
46-549-01 Rev. E
Printed in Mexico
2. Mount the sensor base. Two screw holes are provided,
one is enlarged to allow for sensor alignment. Use #6
pan head screws when mounting the senso r. Two s mal l
additional holes are provided for mounting the sensor
with #18 x 1/2 in. wire nails (br ad s) and a brad driver
(see Figure 2).
Cover Release
Catch
Tamper
Spring
Screw Hole
Screw Slot
Figure 2. Sensor Mounting Holes/Tamper Spring
Wire Nail
Wire Nail
Holes
Holes
Cover With
Electronics
Tab
3. Mount magnet base within 3/8 in. of the sensor base,
centered on the notch or tab. Use two #6 x 1/2 in. pan
head screws or #18 x 1/2 in. wire nails (see Figure 3).
Note
Be sure magnet does not interf ere with door or w i ndo w
opening. Do not use double sided tape to mount
magnet.
4. When prompted by the panel to t rip the s ensor, activa te
the sensor tamper switch by removing the sensor cover.
5. Replace the sensor cover and exit programming mode.
Testing
The following steps describe the general guidelines for performing a dealer sensor test. Refer to the specific panel
installation instructions or reference manual for complete
testing details.
1. Use the panel touchpad to enter the dealer sensor test
mode.
2. Trip the sensor by opening door or window.
3. Listen for the appropriate siren response as described in
the panel installation instructions.
Specifications
Compatibility: All ITI Learn Mode Pane ls and
Receivers
Power Source: One 3.5 VDC Lithium
Battery
Temperature Range: 10 to 120 °F
Dimensions: Sensor- 4.90” x 0.94” x 0.90”
Magnet- 1.50” x 0.50” x 0.50”
All Dimensions (L x W x D)
3/8"
Max
Figure 3. Aligning the Sensor and Magnet
4. Replace the sensor cover.
Programming
The following steps describe the general guidelines for programming (learning) the sensor into panel memory . Refer to
the specific panel installation instructions or reference manual for complete programming details.
1. Set the panel to program mode.
2. Proceed to the LEARN SENSORS menu.
3. Select the appropriate sensor group and sensor number
assignments.
Notices
This device complies with FCC Rules Parts 15 and 68. Operation is
subject to the following two conditions:
This device may not cause harmful interference.
This device must accept any interference that may be received, includ-
ing interference that may cause undesired operation.
Changes or modifications not expressly approved by Interactive Tech-
nologies, Inc. can void the user’s authority to operate the equipment.
651-777-2690
651-779-4890
ITI, Commander, UltraGard, and Simon are registered trademarks of Interactive
Technologies, Inc.
Learn Mode, Concord, and Concord Express, are trademarks of Interactive
Technologies, Inc.