IDEAL INDUSTRIES INC.
TECHNICAL MANUAL
MODEL 61-160 series
The Service Information provides the following information
• Precautions and safety information
• Specifications
• Performance test procedure
• Calibration and calibration adjustment procedure
Document: September1, 2009 Page 1of 10
TABLE OF CONTENTS
Title
Page
Introduction 1
Precautions and Safety Information 1
Safety Information 1
Specifications 2
General Specification 2
Voltage Specifications 2
% Voltage Drop Specifications 2
Impedance Specifications 2
Diode / Continuity Specifications 2
Performance Verification 3
Standardizing a Branch Circuit 4
Table 1, Standardized Data 5
Table 2, Performance Verification Test 5
Calibration 6
Return to Ideal Industries, Inc 6
Document: September1, 2009 Page 2of 10
Introduction
Warning
To avoid shock or injury, do not perform the verification tests or calibration
procedures described in this manual unless you are qualified to do so. The
information provided in this document is for the use of qualified personnel only.
Caution
The 61-150 and 61-160 serials contain parts that can be damaged by static is charge.
Follow the standard practices for handling static sensitive devices.
For additional information about IDEAL INDUSTRIES and its product and services, visit
IDEAL INDUSTRIES web site at: www.idealindustries.com
SAFETY
Review the following safety precautions to avoid injury and prevent damage to this
product or any products connected to it. To avoid potential hazards, use the product only
as specified.
It is recommended that you read through the Operation or User manual before starting.
Not all Caution, Warning, or Danger precautions are listed in this manual.
CAUTION
These statements identify conditions or practices that could result in damage to the
equipment or other property.
WARNING
These statements identify conditions or practices that could result in personal injury or
loss of life.
Specific precautions
Do not operate without covers: To avoid personal injury, do not apply any voltage to
the product without the covers in place.
Electric overload: Never apply a voltage to a Contact on the product that is outside the
range specified for that connector.
Avoid electric shock: To avoid injury or loss of life, use care when connecting and
disconnect adapter cord to a receptacle or while using the adapter with alligator
connectors..
Do not operate in wet/damp conditions: To avoid electric shock, do not operate this
product in wet or damp conditions.
Document: September1, 2009 Page 1of 10