Hobart HC24EA3 General Manual

701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
Item # _____________________________________
Quantity ___________________________________
C.S.I. Section 11400
HC24EA COUNTER CONVECTION
STEAMER – PROFESSIONAL CONTROL
STANDARD FEATURES
Stainless steel exterior and cooking compart­ment with coved interior corners.
Professional Control Package includes:
– Superheated Steam System – Staged Fill – Lighted power switch with cook and ready
lights
– Auto drain with Smart Drain System
(timed drain) with PowerFlush
– Timer 60 minute 60 cycle (50 cycle x 1.2)
with Constant Steam Setting
– Cord strain relief
High output stainless steel steam generator.
Heavy duty door and door latch mechanisms.
Leveling feet.
Shipped for 208/60-50/3 electrical service.
Can be eld converted to 208/60-50/1 and 240/60-50/3 and 240/60-50/1.
Split water line connection. 11⁄2" NPT drain connection.
One year limited parts and labor warranty.
MODELS
HC24EA3 – 3 Pan Capacity HC24EA5 – 5 Pan Capacity
Specications, Details and Dimensions on Inside and Back.
ACCESSORIES
4" legs.
12" x 20" stainless steel pans:
– 1" deep (solid) (perforated). – 21⁄2" deep (solid) (perforated). – 4" deep (solid) (perforated).
Stainless steel pan cover.
Open leg stand.
28" open leg stand with pan slides
24"w x 28"h.
34" open leg stand with pan slides
24"w x 34"h.
Set of two universal pan slides for open
leg stand.
Stand sliding shelf.
Stack kit.
Removable sliding shelf.
Cord and plug set.
Casters.
Water treatment system.
Shown on optional stand with
extra set of pan slides and pans
F-40122 – HC24EA Counter Convection Steamer – Professional Control Page 1 of 4
HC24EA COUNTER CONVECTION STEAMER – PROFESSIONAL CONTROL
SERVICE CONNECTIONS
ELECTRICAL CONNECTIONS: Field Wire Electrical
Connection 11⁄4" (32 mm) K.O. service entrance.
DRAIN: 11⁄2" IPS piped to open drain. No solid connections. 60" length before open air gap opening and not more than two bends or elbows.
GENERATOR WATER SUPPLY: 3⁄4" (19 mm) hose bib to generator, ow rate .5 gpm @ minimum 25 to maximum 50 psi. (170-345 kPa).
CONDENSING WATER SUPPLY: 3⁄4" (19 mm) hose bib to condenser, ow rate .5 gpm @ minimum 25 to maximum 50 psi. (170-345 kPa).
WATER QUALITY STATEMENT
The fact that a water supply is potable is no guarantee that it is suitable for steam generation. Your water supply must be within these general guidelines:
SUPPLY PRESSURE 20 - 60 psig HARDNESS* less than 3 grains SILICA less than 13 ppm TOTAL CHLORIDE less than 4.0 ppm pH RANGE 7-8 UN-DISSOLVED SOLIDS less than 5 microns * 17.1 ppm = 1 grain of hardness
Other factors affecting steam generation are iron content, amount of chloridation and dissolved gases. Water supplies vary from state to state and from locations within a state. Therefore it is necessary that the local water treatment specialist be consulted before the installation of any steam generating equipment.
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
ELECTRICAL DATA
Device Total KW Volts Hz Ph
HC24EA3-3 9.25 208 60 1 43.57
HC24EA3-3 9.25 240 60 1 38.54
HC24EA3-3 9.25 208 60 3 4.25 2.69 2.12 26.54 28.88 20.04
HC24EA3-3 9.25 240 60 3 2.83 3.58 2.83 20.45 23.15 23.15
HC24EA3-4 9.25 480 60 3 2.83 3.58 2.83 10.21 11.57 11.57
HC24EA5-3 15.75 208 60 1 74.82
HC24EA5-3 15.75 240 60 1 65.63
HC24EA5-3 15.75 208 60 3 7.50 4.31 3.75 46.84 49.18 33.57
HC24EA5-3 15.75 240 60 3 5.00 5.75 5.00 36.08 38.79 38.79
HC24EA5-4 15.75 480 60 3 5.00 5.75 5.00 18.04 19.40 19.40
2002 National Electric Code
Kw Per Phase
L1-L2 L2-L3 L3-L1 L1 L2 L3
3 Phase Amps Per Line
Rated Amps
Single Phase
Page 2 of 4 F-40122 – HC24EA Counter Convection Steamer – Professional Control