Henny Penny PFE-591 Installation Manual

Model PFE- 591
SECTION 2. INSTALLATION
2-1. INTRODUCTION
This section provides the installation and unpacking
instructions for the Henny Penny Model PFE-591.
Installation of this unit should be performed only by a qualifi ed service technician.
Do not puncture the fryer with any objects such a
drills or screws as electrical shock or component damage could result.
2-2. UNPACKING
INSTRUCTIONS Note any shipping damage in the presence of the delivery
agent and signed prior to his or her departure.
1. Cut and remove the plastic bands from the main box.
2. Remove the box lid and lift the main box off the fryer.
3. Remove corner packing supports (4).
4. Cut the stretch fi lm from around the carrier/rack box and remove it from the top of the fryer lid.
5. Cut and remove the metal bands holding the fryer to the pallet.
All counterweights must be loaded before unlatching
the lid, or personal injury could result.
6. Remove the fryer from the pallet.
Take care when moving the fryer to prevent personal
injury. The fryer weighs approximately 758 lbs. (344 Kg).
2-1 803
Model PFE- 591
2-2. UNPACKING
7. Remove the counterweights from the pallet, which are INSTRUCTIONS
strapped to the pallet, under the fryer.
(Continued)
Do not drop. The counterweights weigh approximately 18 lbs. (8.1 kg.) each. Handle with care, or personal injury could result.
8. Remove rear cover.
9. Load the seven weights into the counterweight assembly. See page 2-4.
10. Replace rear cover.
11. Cut warning tags from the lid assembly. The lid may now be unlatched.
12. Remove the accessories from inside the fi lter drain pan.
13. Prepare the deadweight valve for operation
The metal packing spacer is placed inside the deadweight valve housing to protect the deadweight orifi ce and dead- weight during shipment. Remove this packing spacer prior to installation, in order to build pressure.
A. Unscrew the deadweight cap.
B. Remove the deadweight.
C. Remove and discard the metal packing spacer.
D. Clean the deadweight orifi ce with a dry cloth.
E. Carefully place deadweight over deadweight orifi ce. Replace deadweight cap, fi nger tight.
14. Remove the protective paper from the fryer cabinet.
Clean exterior surface with a damp cloth.