The controls have four programming levels, a first level mode, a
second level mode, a third level mode, and a special program
mode. In each level, pressing the set switch advances through
the programmable items. Program mode can be entered at
anytime except during an alarm. The left display describes the
item being programmed. The right display shows the item setting and can be changed by pressing the right Up and Down
Switches.
The Low Level Program Mode allows the operator to program
the “global“ set point temperature (if enabled), cook and hold
time, and set up to four alarms for the selected product.
1. Press and hold Set and Temperature Switch for at least
five seconds. A tone will sound, and the left display shows
“OF” and the right display shows the set point temperature.
The temperature LED and all product indicator LED’s flash.
2. Press the right Up and Down Switches to program
desired set point temperature for all products.
3. Press the set switch and left display shows “Slct” and
the right display shows “Prod”. The product LED also
flashes.
4. Press either the left or right Up and Down Switches to select
a product to program, and the LED will be lit next, to the
desired product.
5. Press the set switch and the time LED flashes. The left
displays shows “Fry” and the right display shows the cook
time. Pressing the right Up and Down Switches adjusts the
cook time.
6. Press the set switch and the time LED continues to flash.
The left display shows “Hold,” the right display shows the
hold time and can be adjusted with the right Up and Down
Switches.
7. Press the set switch and the alarm LED flashes. The left
display shows “AL 1”) the right display shows the alarm
time and can be adjusted with the right Up and Down
Switches.
8. Repeat step 8 for alarms 2,3, and 4.
9. Press and hold the Set Switch to exit program mode, or
continue to second level mode.
The Second Level Program Mode allows the operator to program load compensation, load anticipation, proportional control,
filter cycle for the selected product, and the idle parameters.
1. While in the first level mode, push and hold the Set and
Exit Melt Switches for five seconds. The beeper will sound
the left display will show “Slct” (Select) and the right display
will show “Prod” (Product). The Product LED also flashes.
2. Press either the right or left Up and Down Switches to
select a product to program.
3. Press Set Switch and the Other LED flashes. The left display
shows “LdCo,” and the right display shows load compensation setting, and can be adjusted with the right Up and
Down Switches.
4. Press the Set Switch and the Other LED continues to flash.
The left display shows “PC,” the right display shows the
proportional control setting, and can be adjusted with the
right Up and Down Switches.
5. Press the Set Switch and the Other LED continues to flash.
The left display shows. “LdAn,” and the right display shows
load anticipation setting, and can be adjusted with the right
Up and Down Switches.
6. Press the Set Switch and the Other LED continues to flash.
The left display shows “Filtr,” and the right display shows
filter cycles setting, and can be adjusted with the right Up
and Down Switches.
7. Press the Set Switch and the Product LED flashes. Press
~
either right or left Up and Down Switches to select another
product to program. Press and hold the Set Switch to exit the
program mode, or continue on to the third level program
mode.