Henny Penny OG 301, OG-302, OG-303, OE-301, OE-302 User Manual

...
This section provides troubleshooting information in the form of an easy-to-read table.
If a problem occurs during the first operation of a new fryer, recheck the installation per Section 2 of this manual.
Before troubleshooting, always recheck the operating procedure per Section 3 of this manual.
e
T
In the event of a control system failure, the digital display will
show an “Error Message.” These messages are coded: E5, E4, E6, ElO, E15, E41, E50, E51, and E53.
en turn
switc display shows E4, the control board is getting too hot. Check the louvers on each side of the unit for obstuctions. If E4 persists,
Turn switch to OFF position, then turn switch back to ON. If display shows E6, thermal sensor must be replaced. Refer to section 6-4.
El5
E41, E50, E5 1, E53
button. If high limit does not reset, high limit must be replaced per section 6-5, or 6-6.
Drain Switch Close drain, using the drain valve handle. If display still shows Failure
E 15 check drain valve section 6- 13.
Programming Turn switch to OFF, then back to ON. If display shows any of Failure the error codes, the control panel needs replaced.
LE
NG
With switch in POWER position and switch light not illuminated, fryer is complete ly inoperative.
With switch in power position, switch light is on, but all other lights are out ex cept the pump will operate.
Shortening will not heat but lights are on.
Open Circuit
No power to board
Faulty Contactor (elec. model)
Check to see if unit is plugged in. Check breaker or fuse at supply box. Check control panel fuse per Section 6-12.
@ Check POWER switch per Section 6-14. Replace if defective.
.Check voltage at wall receptacle.
Check cord and plug.
Check fuse on PC board.
Faulty Gas Valve (gas model)
Faulty Gas Solenoid (gas
model)
Faulty Probe
Faulty High Limit
Faulty Drain Switch
Check gas valve per Section 6-11.
Check gas solenoid, per Section 6-19.
Check probe per Section 6-4. “Error message” E6.
Check High Limit per Section 6-6, or 6-7. “Error message” ElO.
Check drain switch per Section 6-13. “Error message” E15.
Loading...