Hatco SGCP-36 Installation Manual

0 (0)
Hatco SGCP-36 Installation Manual
English = p 2
hatcocorp.com
Reg ine!
(see page 2)
S'inscrire en ligne!
(voir page 12)

Sneeze Guards

Pare-haleine

SGPT, SGCP, and SGEN Series/Série Installation and Operating Manual Manuel d'installation et d'utilisation

P/N 07.04.718.00

WARNING

Do not operate this equipment unless you have read and understood the contents of this manual! Failure to follow the instructions contained in this manual may result in serious injury or death. This manual contains important safety information concerning the maintenance, use, and operation of this product. If you’re unable to understand the contents of this manual, please bring it to the attention of your supervisor. Keep this manual in a safe location for future reference.

ADVERTENCIA

No opere este equipo al menos que haya leído y comprendido el contenido de este manual! Cualquier falla en el seguimiento de las instrucciones contenidas en este manual puede resultar en un serio lesión o muerte. Este manual contiene importante información sobre seguridad concerniente al mantenimiento, uso y operación de este producto. Si usted no puede entender el contenido de este manual por favor pregunte a su supervisor. Almacenar este manual en una localización segura para la referencia futura.

AVERTISSEMENT

Ne pas utiliser cet équipement sans avoir lu et compris le contenu de ce manuel ! Le non-respect des instructions contenues dans ce manuel peut entraîner de graves blessures ou la mort. Ce manuel contient des informations importantes concernant l'entretien, l'utilisation et le fonctionnement de ce produit. Si vous ne comprenez pas le contenu de ce manuel, veuillez le signaler à votre supérieur. Conservez ce manuel dans un endroit sûr pour pouvoir vous y référer plus tard.

Français = p 12

© 2015 Hatco Corporation

CONTENTS

 

English

Important Owner Information ..............................................

2

Introduction...........................................................................

2

Important Safety Information...............................................

3

Model Designation................................................................

3

Model Description.................................................................

4

Specifications........................................................................

5

Dimensions ..........................................................................

5

Installation .............................................................................

6

General ................................................................................

6

SGPT model Installation ......................................................

6

SGCP model Installation......................................................

7

SGEN model Installation......................................................

8

Maintenance ..........................................................................

9

General ................................................................................

9

Daily Cleaning......................................................................

9

Limited Warranty.................................................................

10

Addendum ...........................................................................

11

Authorized Parts Distributors ............................

Back Cover

IMPORTANT OWNER INFORMATION

 

 

 

 

 

Record the model number, serial number, voltage, and purchase

Business

 

date of the unit in the spaces below (specification label located

Hours:

7:00 am to 5:00 Pm Central Standard Time (CST)

on the post). Please have this information available when calling

 

(Summer Hours: June to September

Hatco for service assistance.

 

 

7:00 am to 5:00 Pm CST mondayThursday

 

 

 

 

model No. ________________________________________

 

7:00 am to 4:00 Pm CST Friday)

Serial No. ________________________________________

Telephone: 800-558-0607; 414-671-6350

Voltage __________________________________________

E-mail:

partsandservice@hatcocorp.com

 

 

Date of Purchase __________________________________

Fax:

800-690-2966 (Parts and Service)

 

414-671-3976 (International)

 

 

 

 

 

 

 

 

 

 

Register your unit!

 

24 Hour 7 Day Parts and Service

 

Completing online warranty registration will prevent delay in

 

 

Assistance available in the United States

 

obtaining warranty coverage. access the Hatco website at

 

 

and Canada by calling 800-558-0607.

 

www.hatcocorp.com, select the Parts & Service pull-down

 

additional information can be found by visiting our web site at

 

menu, and click on “Warranty Registration”.

 

 

 

 

www.hatcocorp.com.

 

 

 

INTRODUCTION

Enhance and protect food products simultaneously with Hatco Sneeze Guards. Ideal for buffet lines and serving stations, the Sneeze Guards guarantee resilient functionality in a stylish design, allowing you to safeguard your food while displaying it clearly to customers.

Sneeze Guards are products of extensive research and field testing. The materials used were selected for maximum durability, attractive appearance, and optimum performance. Every unit is inspected thoroughly prior to shipment.

This manual provides installation and safety instructions for Sneeze Guards. Hatco recommends all installation and safety instructions appearing in this manual be read prior to installation of the unit.

Safety information that appears in this manual is identified by the following signal word panels:

WARNING

 

not

WARNING indicates a hazardous situation which, if

avoided, could result in death or serious injury.

 

 

CAUTION

 

not

CAUTION indicates a hazardous situation which, if

avoided, could result in minor or moderate injury.

 

NOTICE

 

 

NOTICE is used to address practices not

related

to

personal injury.

 

 

2

Form No. SGm-0815

 

 

 

English

 

IMPORTANT SAFETy INFORMATION

 

 

 

 

CAUTION

Locate unit in an area that is convenient for use. Location should be level to prevent unit from falling or moving accidentally.

NOTICE

DO NOT submerge or saturate with water. Unit is not waterproof.

Do not steam clean or use excessive water on unit.

This unit is not “jet-proof” construction. Do not use jetclean spray to clean unit.

This unit has no “user-serviceable” parts. If service is required on this unit, contact an Authorized Hatco Service Agent or contact the Hatco Service Department at 800-558-0607 or 414-671-6350; fax 800-690-2966; or International fax 414-671-3976.

NOTICE

Use non-abrasive cleaners and cloths only. Abrasive cleaners and cloths could scratch finish of unit, marring its appearance and making it susceptible to soil accumulation. Clean unit daily to avoid malfunctions and maintain sanitary operation.

Do not use harsh chemicals such as bleach, cleaners containing bleach, or oven cleaners to clean unit.

NSF Requirements

SGPT and SGCP models: The vertical distance between the finished floor and the bottom leading edge of a food shield must be 52″ (1321 mm) or less.

SGPT and SGCP models: The horizontal distance between the front of countertop equipment and the bottom leading edge of a food shield shall be 7″ (178 mm) or more.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MODEL DESIGNATION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S G X X - X X

Sneeze Guard

 

 

 

 

 

 

 

 

 

 

Width (in inches)

 

 

 

 

 

 

 

 

 

 

PT = Portable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CP = Countertop Post

 

 

 

 

 

 

 

 

 

 

 

 

EN = Enclosure

 

 

 

 

 

 

 

 

 

 

 

 

Form No. SGm-0815

3

 

model SGCP

 

 

 

 

 

English

MODEL DESCRIPTION

 

 

 

 

 

 

 

All Models

SGCP Models

Enhance and protect food products simultaneously with Hatco

The SGCP model is mounted to a countertop with an adjustable

Sneeze Guards. Ideal for buffet lines and serving stations, the

height.

Sneeze Guards guarantee resilient functionality in a stylish

 

 

design, allowing you to safeguard your food while displaying it

 

 

clearly to customers. Hatco sneeze guards meet NSF

 

 

standards.

 

Adjustment

SGPT Model

 

 

 

Height

The SGPT model is a portable sneeze guard with an adjustable

 

Knobs

height.

 

 

Height

Adjustment

Knobs

SGEN Models

The SGEN model is mounted to the countertop and offers protection on three sides and overhead.

model SGPT

model SGEN

4

Form No. SGm-0815

 

English

Dimensions

SPECIFICATIONS

25-1/4″–61-1/4″ (642–1556 mm)*

SGPT Models

 

22″

 

(559 mm)

 

19-3/16″–24-5/16″

 

(487–618 mm)

20-1/8″–56-1/8″*

 

(511–1426 mm)

 

21-5/8″–57-5/8″*

 

(550–1464 mm)

 

25-1/4″–61-1/4″ (642–1556 mm)*

SGCP Models

 

22″

 

(559 mm)

 

20-3/4″–25-7/8″

 

(526–657 mm)

18-9/16″–54-9/16″*

 

(472–1386 mm)

 

21-5/8″–57-5/8″*

 

(550–1464 mm)

 

22″–58″ (559–1473 mm)*

SGEN Models

 

19″

 

(482 mm)

16-7/16″–52-7/16″* (418–1332 mm)

19-1/2″–55-1/2″* (495–1410 mm)

60°

12″–17-1/4″ (307–438 mm)

18-1/2″ (470 mm)

20-5/16″ (516 mm)

60°

13-1/2″–18-1/2″ (345–470 mm)

18″ (457 mm)

13-3/16″ (335 mm)

16-5/16″ (414 mm)

* Units are sold in increments of 6″ (152 mm) widths.

Add the following to the smallest measurement in the range to determine each model’s specific width dimensions:

SGPT-24, SGCP-24, and SGEN-22 models add 0″ (0 mm) SGPT-30, SGCP-30, and SGEN-28 models add 6″ (152 mm) SGPT-36, SGCP-36, and SGEN-34 models add 12″ (305 mm) SGPT-42, SGCP-42, and SGEN-40 models add 18″ (457 mm) SGPT-48, SGCP-48, and SGEN-46 models add 24″ (610 mm) SGPT-54, SGCP-54, and SGEN-52 models add 30″ (762 mm) SGPT-60, SGCP-60, and SGEN-58 models add 36″ (914 mm)

Form No. SGm-0815

5

 

 

 

 

 

 

 

 

 

 

English

INSTALLATION

 

 

 

 

 

 

 

 

 

 

 

 

 

General

 

5. Slide the glass mounting bracket through the angle

Sneeze Guards are shipped with some components pre-

adjustment pins. make sure both brackets are inserted into

the pins the same way to ensure both sides are angled

assembled. Care should be taken when unpacking the shipping

properly for a correct fit. The unit is designed for a 60° angle.

carton to avoid damage to unit and components enclosed.

6. Secure the glass mounting bracket into place by tightening

NOTE: To prevent delay in obtaining warranty coverage,

the knob into the post.

 

 

complete online warranty registration. See the

 

 

 

 

 

ImPORTaNT OWNER INFORmaTION

section for

7. Secure the top glass sneeze guard.

details.

 

a. Insert the mounting bolt through the glass sneeze guard.

SGPT Model Installation

 

 

b. Place a glass bushing between the glass sneeze guard

NOTE: Remove tape and protective packaging from the

and the glass mounting bracket.

surfaces of the unit.

 

c. Screw the mounting bolt into the glass mounting bracket.

1. Secure the base support to the bottom channel of the two

d. Repeat on three remaining glass sneeze guard holes.

legs using the supplied screws.

 

8. move the sneeze guard mounts to the desired position and

• The base support can be installed on either side of leg.

secure to the post using the knob. The bottom edge of the

 

 

• Remove the base plugs and install on opposite side, if

top glass must be 52″ (1321 mm) or less above floor.

necessary.

 

9. Secure the side glass to the outside of each post.

2. Secure the two posts to the base using the supplied screws.

a. Tighten the short knob through the glass and into the

• The posts can be installed on middle or end of leg.

sneeze guard mount towards the top.

• Remove the leg plugs and install on opposite side, if

b. Place a glass bushing between side glass and post.

necessary.

 

c. Hold the side glass clamp onto the post.

3. Slide the side glass clamp then the sneeze guard mount

d. Tighten the long knob into the bottom hole through the

onto each post.

 

 

glass bushing and into the clamp.

4. Slide the angle adjustment pins through the spacer and into

e. Repeat this step on the opposite end.

the sneeze guard mount holes. Repeat on opposite post.

10. Place the unit in the desired location.

 

 

 

 

Mounting Bolt

 

 

 

 

Angle Adjustment

 

 

 

 

Pins

 

 

 

Glass

Sneeze Guard

 

 

Bushing

Mount

 

 

 

 

 

Short

 

 

 

Knob

Knob

 

 

 

Glass Mounting

Side

 

 

 

Bracket

 

 

Angle Adjustment

Glass

 

 

Clamp

 

 

 

Spacer

Glass

 

 

 

Knob

 

 

 

Bushing

 

 

 

Post

 

 

 

 

Leg Plug

Base

 

 

 

Leg

Long

Base

Plug

Knob

Support

Leg Plug

 

 

 

 

Base Plug Screw

 

 

 

Screw

 

 

Post Screw

Base Support Screw

SGPT model Installation

 

 

 

6

Form No. SGm-0815

 

 

 

 

 

 

English

 

 

 

INSTALLATION

 

 

 

 

 

 

 

 

 

 

SGCP Model Installation

 

7. Place the posts in the desired location and secure the legs

NOTE: Remove tape and protective packaging from the

into the countertop.

 

• move the mounting covers to access the mounting holes.

surfaces of the unit.

 

1. Slide the mounting cover, side glass clamp, then the sneeze

• Use the “mounting Template” located in the aDDENDUm

guard mounts onto each post.

 

section at the end of this manual.

2. Slide the angle adjustment pins through the spacer and into

8. Secure the side glass to the outside of each post.

the sneeze guard mount holes. Repeat on opposite post.

a. Tighten the short knob into the top hole.

3. Slide the glass mounting bracket through the angle

b. Place a glass bushing between the side glass and the

adjustment pins. make sure both sides are inserted into the

post.

 

pins the same way to ensure both sides are angled properly

c. Hold the side glass clamp onto the post.

for a correct fit. The unit is designed for a 60° angle.

d. Tighten the long knob into the bottom hole through the

4. Secure the glass mounting bracket into place by tightening

glass bushing and into the post.

the knob into the post.

 

 

e. Repeat this step on the opposite end.

5. Secure the top glass sneeze guard.

 

 

 

 

a. Insert the mounting bolt through the glass sneeze guard.

 

 

b. Place a glass bushing between the glass sneeze guard

 

 

and the glass mounting bracket.

 

 

 

c. Screw the mounting bolt into the glass mounting bracket.

 

 

d. Repeat on the three remaining glass sneeze guard

 

 

holes.

 

 

 

6. move the sneeze guard mounts to the desired position and

 

 

secure to the post using the knob. The bottom edge of the

 

 

top glass must be 52″ (1321 mm) or less above floor.

 

 

 

 

 

Mounting Bolt

 

 

 

 

Angle Adjustment

 

 

 

 

Pins

 

 

 

Glass

Post

 

 

 

Sneeze Guard

 

 

Bushing

 

 

 

Mount

Short

 

 

Knob

 

Knob

 

 

 

 

 

 

Glass

 

 

 

 

Mounting

 

 

 

 

Bracket

 

 

 

Side

Angle

 

 

 

Adjustment

 

 

 

Glass

Spacer

 

 

 

Clamp

Knob

 

 

 

 

 

 

 

 

Mounting Cove

Long

 

 

 

 

Knob

 

Countertop Mounting

Screw

SGCP model Installation

Form No. SGm-0815

7

 

 

 

 

 

 

English

INSTALLATION

 

 

 

 

 

 

 

SGEN Model Installation

4. Secure the top glass to the top of each post.

1. Place each post in the desired location and secure the legs

a. Insert the mounting bolt through post from underneath.

into the countertop.

b. Place a glass mount and glass bushing onto the bolt.

• move the mounting covers to access the mounting

c. Slide the glass onto the bolt and secure using nut.

holes.

d. Repeat on the three remaining top glass holes.

• Use the “mounting Template” located in the aDDENDUm

 

 

section at the end of this manual.

 

 

2. Secure the back glass to the outside of each post.

 

 

a. Insert the mounting bolt through post.

 

 

b. Place a glass mount then a glass bushing onto the bolt.

 

 

c. Slide the glass onto the bolt and secure using nut.

 

 

d. Repeat on the three remaining back glass holes.

 

 

3. Secure the side glass to the outside of each post.

 

 

a. Place a glass bushing between the side glass and the

 

 

post.

 

 

b. Hold the side glass clamp onto the post.

 

 

c. Tighten the bolt into the clamp through the top hole of

 

 

side glass.

 

 

d. Repeat on the three remaining side glass holes.

 

 

e. Repeat this step on the opposite end.

 

 

 

Mounting Nut

Glass Bushing

Glass Mount

Glass

Glass Bushing

Clamp

 

 

Mounting

 

Bolt

Mounting

Bolt

Mounting

Cover

Countertop

Mounting

Screw

Mounting Nut

SGEN model Installation

8

Form No. SGm-0815

 

Loading...
+ 16 hidden pages