Hatco C-4, C-5, C-6, C-7, C-9 General Manual

...
0 (0)
Hatco C-4, C-5, C-6, C-7, C-9 General Manual

ITEM#

COMPACT ELECTRIC BOOSTER WATER HEATERS

Models C-4, -5, -6, -7, -9, -12, -13, -15, -17, -18, -24, -27, -30, -36, -39, -45, -54, -57

The Hatco Compact Electric Booster Water Heater provides all the 180°F (82°C) final rinse water required to sanitize and flash-dry dishes and flatware.

FLEXIBILITY

The space saving Compact is easy to install next to the dishwasher with slide brackets or on 6" (152 mm) legs. The storage capacity is 6 gallons (23 liters).

QUALITY

The following features assure the finest performance for years to come:

All models include a Castone® lined tank with a 10-year limited warranty.

Features include a temperature/pressure relief valve, a pressure reducing valve, two temperature/pressure gauges, a high-temperature limit control, pilot indicator light, on-off switch, and a low-water cut-off to prevent element burnout due to a low water condition.

Available with slide brackets for mounting under a dishtable.

Each booster has fiberglass insulation to minimize heat loss.

Hatco electric booster heaters are factory pre-plumbed and pre-wired with calibrated immersion thermostat and high-temperature limit switch.

A stainless steel front panel and powder-coated silver-gray hammertone body is standard on all Compact models.

Swing-away front panels with low-water cut-off, control fuses and transformer allow quick access to probes and elements for easier serviceability.

Model C-18 on 6" (152 mm) legs

Model C-24 on 6" (152 mm) legs

Water Temperature Recovery Table

Compact Model

40°F (22°C) Rise

70°F (39°C) Rise

C-4

40 gph (

151

Iph)

23 gph (

87

Iph)

C-5

50 gph (

189

Iph)

29 gph (

110

Iph)

C-6

60 gph (

227

Iph)

34 gph (

129

Iph)

C-7

70 gph (

265

Iph)

40 gph (

151

Iph)

C-9

90 gph (

341

Iph)

52 gph (

197

Iph)

C-12

120 gph (

454

Iph)

69 gph ( 261 Iph)

C-13

135 gph (

511

Iph)

77 gph ( 292 Iph)

C-15

151 gph (

572

Iph)

86 gph ( 326 Iph)

C-17

173 gph (

655

Iph)

99 gph ( 375 Iph)

C-18

181 gph ( 685 Iph)

103 gph ( 390 Iph)

C-24

241 gph ( 912 Iph)

138 gph ( 522 Iph)

C-27

271 gph (1026 Iph)

155 gph ( 587 Iph)

C-30

301 gph (1139 Iph)

172 gph ( 651 Iph)

C-36

361 gph (1367 Iph)

206 gph ( 780 Iph)

C-39

391 gph (1480 Iph)

224 gph ( 848 Iph)

C-45

452 gph (1711 Iph)

258 gph ( 977 Iph)

C-54

542 gph (2052 Iph)

310 gph (1174 Iph)

C-57

573 gph (2169 Iph)

326 gph (1234 Iph)

 

 

 

 

 

 

 

WATER QUALITY REQUIREMENTS

Incoming water in excess of 3.0 grains of hardness per gallon (GPG) (.75 grains of hardness per liter) must be treated and softened before being supplied to booster heater(s). Water containing over 3.0 GPG (.75 GPL) will decrease the efficiency and reduce the operating life of the unit.

Note: Product failure caused by liming or sediment buildup is not covered under warranty.