Harman Stove Company Accentra Service Training

Pellet Stove Service Training
Includes all pellet burning units
Manufactured by Harman Stove
Company
Harman Pellet Service Training 1
Objectives
Understand the Harman patented feed system
Apply knowledge to properly diagnose or troubleshoot
Properly inform and educate consumers about pellet burning
Harman Pellet Service Training 2
Advance
Automatic Ignition
Room Sensor control
0 to 48,000 BTU
Gold or Bright nickel trim
Tile inserts are standard
Now cleaner glass!
Easier cleaning access
Cast Iron rear brick panel
Smoked Glass Hopper Lid
Optional Log Kit
available
Harman Pellet Service Training 3
P-68
Automatic Ignition
Room Sensor control
0 to 68,000 BTU
Mirrored Glass
76 Lb. Hopper capacity
Easy cleaning access
Harman Pellet Service Training 4
Options Include
;
Brushed Stainless or
Bright Nickel Door trim
Louvers to Match
Heat Shields Hopper Extension Ash Door Tile Kit
Slate Tiles
3 Piece Log Set
P-61 & P-61A
8,000 to 61,000 BTU
Manual or Automatic Ignition
Room Sensor control
72 lb. Hopper Capacity
Options Include
;
Brushed Stainless or
Bright Nickel Door trim
Louvers to Match
Heat Shields Hopper Extension Ash Door Tile Kit
Slate tiles
3 Piece Log Set
Harman Pellet Service Training 5
PP-38+
7,000 to 43,000 BTU
Manual Ignition Only
Thermostat Ready
50lb. Hopper Capacity
Options Include
;
Gold Door
Sunrise Frame
Heat Shields Hopper Extension Ash Door Tile Kit Gold Louver Trim
3 Piece Log Set
Harman Pellet Service Training 6
Invincible Fireplace Insert
8,000 to 53,000 BTU
Manual Ignition
Room Sensor control
40 lb. Hopper Capacity
Easy slide out design
Options Include
Brass window trim
Gold air grill plates
3 pc. Log set Oversize and
Custom wings
Harman Pellet Service Training 7
Accentra Cast Iron Pellet Stove
Harman Pellet Service Training 8
0 to 40,000 BTU
Automatic Ignition
Quiet operation
Room sensor control
Smoked Glass Hopper Lid
Options:
Floor Protector
Leg Kit
Accentra Insert
0 to 40,000 BTU
Automatic Ignition
Room sensor control
Track system frame
57 Lb. Hopper Capacity
Options Include
2 Smaller hoppers
Wing extensions
Log set
Service rail kit
Outside air kit
Zero-clearance box
Mantles and
hearths
Harman Pellet Service Training 9
Harman Pellet Service Training 10
The XXV
0 to 50,000 BTU
Automatic Ignition
Mirrored Glass
Silent operation
Room sensor control
Highly detailed Castings
65 Lb. Hopper Capacity
Options:
Top flue conversion
25
th
Anniversary logo
XXV Top Flue Option
Attaches to the exhaust on the rear of the stove, and extends it to the top with a six inch stub. This gives the appearance of a wood stove and also allows venting with existing single wall, connector. A 12 inch piece of 4”PL vent is included to act as an insulator.
Harman Pellet Service Training 11
PF-100 Hot Air Furnace
0 to 112,000 BTU
Automatic Ignition
Room temp control
160lb. Hopper capacity
1000 cfm blower
Options
1450 and 2000 c.f.m. blower
Outside air flex pipe
A/C relay
Harman Pellet Service Training 12
PC – 45 Corn Stove
0 to 45,000 BTU
Automatic Ignition
Room sensor control
Patented Pellet Feeder
Stirrer to ensure complete burn
Accordion heat exchanger
80 lb. Hopper capacity
Options Include
;
Bright Nickel or
Brushed Stainless
Door Trim
Matching Louvers
Heat Shields
Hopper Extension
Ash Door Tile Kit
3 Piece Log Set
Pellet grate
Hopper Strainer
Harman Pellet Service Training 13
Pellet Stove Service Training
Installation Guidelines
Harman Pellet Service Training 14
Installation / Helpful Hints
Always maintain proper clearance to combustible
materials
Floor protection required
Check with and follow local codes
Check for proper power supply at wall outlet
Use only approved pellet venting materials
Recommended to use at least 4 feet of vertical venting
whether inside or out
Limit the amount of horizontal venting
Always record the draft reading upon completion of
installation
Harman Pellet Service Training 15
Harman Pellet Service Training 16
This drawing shows the recommended venting
Configuration for a Harman pellet stove.
90 & 45 degree elbows
4ft. Vertical rise
Cleanout “T”
Wall strap
Use only approved pellet venting
Standard Venting Method
Outside Air Option
All but Invincible series can be connected to 100% outside air.
Benefits Include
:
Higher efficiency
Allows termination of venting to be closer to windows or doors
Does not change air quality in the home
Harman Pellet Service Training 17
Outside Air Components
Air Intake W/ Flapper
Rear view of stove
* Outside Air Weldment
Part # 1-10-08542
* 25 ft. flex # 1-00-08543
* 3 ft. flex # 2-00-08543
Direct vent wall pass-thru
# 1-00-677077
* PF100 furnace uses 2-3/4 in. flex pipe
Harman Pellet Service Training 18
Loading...