SAFETY NOTICE
PLEASE READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE YOUR NEW ROOM HEATER. FAILURE
TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR EVEN DEATH.
IF THIS HARMAN STOVE IS NOT PROPERLY
LOW INSTALLATION DIRECTIONS.
CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION
REQUIREMENTS IN YOUR AREA.
CONTACT YOUR LOCAL AUTHORITY (SUCH AS MUNICIPAL BUILDING DEPARTMENT, FIRE DEPARTMENT, FIRE
PREVENTION BUREAU, ETC.) TO DETERMINE THE NEED FOR A PERMIT.
CETTE GUIDE D'UTILISATION EST DISPONIBLE EN FRANCAIS. CHEZ VOTRE CONCESSIONNAIRE DE HARMAN
STOVE COMPANY.
INSTALLED, A HOUSE FIRE MAY RESULT. FOR YOUR SAFETY, FOL-
WHAT TO DO IF YOU SMELL GAS
• DO NOT TRY TO LIGHT ANY APPLIANCE.
• DO NOT TOUCH ANY ELECTRICAL SWITCH; DO NOT USE ANY PHONE IN YOUR BUILDING.
• IMMEDIATELY CALL YOUR GAS SUPPLIER FROM A NEIGHBOR'S PHONE. FOLLOW THE GAS SUPPLIER'S
INSTRUCTIONS.
• IF YOU CANNOT REACH YOUR GAS SUPPLIER, CALL THE FIRE DEPARTMENT.
Clearances
Venting
Test for Flue Spillage
Assembly
Connecting to a Gas Supply
Connecting the Cordset and Thermostat
Air Shutter Adjustment
Monitoring the Gas Flame
listed gas-red vented room heater tested by Intertek
Testing/Warnock Hersey to ANSI standard Z21.882002, CSA 2.33-M02, and CAN/CGA-2.17-M91.
The installation of the Clarity Vented Gas Heater
must conform with local codes, or in the absence of
local codes, with the current edition of National Fuel
Gas Code, ANSI Z223.1 — latest edition and CAN
1-B1-149.1 and .2 Installation Code.
The Clarity 929BV is not for use in mobile homes.
CAUTION: This appliance must be vented to the
outside.
Installation and repair of the Clarity Vented Gas
Heater should be done by a qualied service person.
The appliance should be inspected before use and at
least annually by a qualied service person. More frequent cleaning may be required due to excessive lint
from carpeting, bedding material, etc. It is imperative
that control compartments, burners, and circulating air
passageways of the Clarity be kept clean.
When operating your Harman Clarity Gas Heater,
respect basic safety standards. Read these instructions
carefully before you attempt to operate the heater.
Failure to do so may result in damage to property or
personal injury and may void the product warranty.
Consult with your local building code agency and
insurance representative before you begin your instal
lation to ensure compliance with local codes, including
the need for permits and follow-up inspections.
Several issues must be addressed when selecting a
suitable location for your Clarity Gas Heater. Observ
ing required clearances to combustible materials, the
proximity to a safe chimney or venting system,and
the accessibility of the gas and electrical supply must
all be considered. In addition, selecting a location that
takes advantage of the building's natural air ow is
also desirable to maximize the heating effectiveness
of the heater. In many cases, this is a central location
within the building.
Adequate combustion and ventilation air must be
provided.
-
-
3
Due to high temperatures, the Clarity Vented Gas
Heater should be located out of trafc and away
from furniture and draperies.
Children and adults should be alerted to the haz-
ards of high surface temperatures and should stay
away to avoid burns or clothing ignition.
Young children should be carefully supervised
when they are in the same room as the Clarity
Vented Gas Heater.
Clothing or other ammable materials should
not be placed on or near the Clarity Vented Gas
Heater.
INSTALLATION
CLEARANCES
The following clearances to combustibles must be
observed:
Unit to left sidewall 9" (230 mm)
Unit to right sidewall 9" (230 mm)
Unit corner to walls 4" (100 mm)
Rear of unit to back wall 3" (75 mm)
(measured from rear of draft hood to wall)
Unit to alcove ceiling 18" (460 mm)
Maximum alcove depth 14" (355 mm)
Clearance from corner of unit to walls
Clearance to alcove ceiling
Sidewall Clearance
Clearance to Back wall
Maximum alcove depth
In addition to these clearances, adequate accessibility clearance for servicing and proper operation must be
maintained.
Do not in any way obstruct the combustion air inlets
that are located under the heater.
If this appliance is installed directly on carpeting, tile
or other combustible material other than wood ooring the
appliance shall be installed on a metal or wood panel ex
tending at least the full width and depth of the appliance.
4
-
VENTING
Use Only Approved Venting
The Clarity gas heater is tested and listed for connection
to a 4" (100 mm) listed Class B venting system.
If the unit is installed to vent through an approved masonry
chimney or a factory-built chimney system, an approved
Class B chimney liner must be used.
Observe local codes when venting the Clarity. If no local
codes exist, follow the current edition of ANSI Z223.1 and
CAN1- B149 installation codes.
Do not connect the venting to the ue of a chimney that
serves a separate solid-fuel burning appliance.
The venting manufacturer's installation instructions must
be followed exactly.
IMPORTANT: Because of the high efciency and low
ue gas temperatures of this appliance, it is important that
it be connected to a well-sealed and efcient venting system
which is capable of registering a negative pressure while
the stove is in operation.
The most efcient venting systems are those that have a
minimum number of bends and minimal horizontal runs.
The Clarity gas heater is equipped with a thermally acti
vated vent safety switch that will shut down the main burner
if the heater is not properly venting. The safety switch will
automatically reset after the heater has cooled down.
The switch will continue to cycle off and on until the
venting problem is corrected. If you are unable to correct
the venting problem, seek expert advice from your Harman
dealer or installer.
DO NOT DISCONNECT OR BYPASS THE VENT
SAFETY SWITCH.
WARNING: Operation of this heater when not connected to a properly installed and maintained venting
system or tampering with the vent safey shutoff system
can result in carbon monoxide (CO) poisoning and pos
sible death.
The Clarity gas heater is equipped with its own internal
draft hood so no additional external draft hood is required.
The heater should be installed so that the draft hood is in
the same atmospheric pressure zone as the air inlets to the
heater.
TEST FOR FLUE SPILLAGE
A spillage test should always be made at the completion
of the installation.
1. Start all exhaust fans in the home and then close all
doors and windows in the room containing the heater.
2. Light the heater and allow it to run for 5 minutes on the
high output setting. If the convection air blower is installed,
it should be turned off for the test.
3. Hold a match or other source of smoke near the draft
hood outlet on the upper back of the stove.
-
4. If the smoke is not drawn in, turn off the heater and
determine the cause of the lack of draft. If necessary, seek
expert advice.
For sites with swirling or turbulent wind conditions, a
wind cap may solve the problem.
-
5
ASSEMBLY
The Clarity is shipped from the factory with the log set
packed inside the rebox. To prepare the stove for installation, the log set must be unpacked, the appropriate burner
system module for either natural gas or propane installed,
and the logs installed.
1
Removing the Glass Front
NOTE: The glass front is heavy. Be prepared for its
weight when lifting it to avoid damage during removal.
The wing doors on each side are held closed by magnets.
Push on each door to open it. Loosen the wing nut on each
of the two levers. Grasp each lever and push to the rear to
disengage the front. To keep the levers in the disengaged
position, tighten the wing nuts. Lift the glass front slightly
and remove it from the stove. Set the glass aside in a safe
place where it will not be damaged.
WARNING: Do not abuse the Clarity's glass by
striking, slamming, or similar trauma. Do not oper-
ate the Clarity Vented Gas Heater with the glass panel
removed,
The front is released when
levers on the left and
right sides are pushed to
the rear
2
3
The log set components are shipped from the factory
individually wrapped and packed inside the stove. Take them
out of the stove, then carefully remove the wrapping. Handle
the logs gently as they may be damaged easily.
4
cracked or broken. Use only glass supplied by Harman
and approved for use with this heater. Do not use substitute materials. Replacement of the panel should be done
by a licensed or qualied service person.
Remove and Unwrap the Log Set
As shown in the photo above right, the log set consists
of a back log (1), a center log that has a pilot-viewing port
in the left end (2), ember strip (3), and a branch that rests on
top (4).
In addition, there are two side brick panels and a back
brick panel.
6
Loading...
+ 14 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.