Fujitsu AOU12RQ Installation Manual

0 (0)
Fujitsu AOU12RQ Installation  Manual

Fig. 1 Indoor Unit

1 Operating Control Panel (Fig. 2)

2AIR CLEANER RESET / MANUAL AUTO button

Intake grill opening mechanism.

When the remote control is not available for use, this button can be used as a Quick-start button. However when the Air Cleaning check function (see page 13) is in operation, this button is used as a reset button.

3 Indicator Lamps (Fig. 3)

4 Remote Control Signal Receiver

5 OPERATION Indicator Lamp (red)

6TIMER Indicator Lamp (green)

If the TIMER indicator lamp flashes when the timer is operating, it indicates that a fault has occurred with the timer setting (See Page G Auto Restart).

7 AIR CLEAN Indicator Lamp (green)

8 SWING Indicator Lamp (orange)

9 Intake Grille (Fig. 4)

0 Air Filter

A Air Flow Direction Louver

BRight-Left Louver

(behind Air Flow Direction Louver)

C Drain Hose

D Electrical Air Cleaning Filter

Fig. 5 Outdoor Unit

E Intake Port

F Outlet Port

G Pipe Unit

● Refer to the folded out page on the cover.

Fig. 6 Remote Control Unit H MASTER CONTROL button

I SET TEMP. / SET TIME buttons (+/-) J Signal Transmitter

K TIMER button

L FAN CONTROL button M START/STOP button N AIR CLEAN button

O SET button

P SWING button Q ACL button

R TIME ADJUST button

Rear side (Fig. 7)

STEST RUN

Touch the two metal contacts with a metallic object to send the signal to perform a test run.

Perform a test run only when installing the air conditioner. If the signal to perform a test run is received during normal operation, the air conditioner’s thermostat will malfunction.

If the signal to perform a test run is received during normal operation, the unit will switch to the test operation mode and the indoor unit’s OPERATION and TIMER indicator lamps will flash simultaneously.

To stop the test operation mode, press the START/STOP button to stop the air conditioner.

T Remote Control Unit Display (Fig. 8) U Transmit Indicator

V Clock Display

W Operating Mode Display X T imer Mode Display

Y Fan Speed Display

Z Temperature Set Display [ Timer Set Indicator

\ Temperature Set Indicator

En-2

FEATURES AND FUNCTIONS

AUTO CHANGEOVER

The operation mode (cooling, heating) is switched automatically to maintain the set temperature, and the temperature is kept constant at all times.

MILDEW-RESISTANT FILTER

The AIR FILTER has been treated to resist mildew growth, thus allowing cleaner use and easier care.

SLEEP TIMER

When SLEEP is selected be pressing TIMER button during Heating mode, the air conditioner’s thermostat setting is gradually lowered during the period of operation; during Cooling or Dry mode, the thermostat setting is gradually raised during the period of operation. When the set time is reached, the unit automatically turns off.

SWING OPERATION

The Air Flow Direction Louvers swings automatically up and down so that the air speeds to every nook and corner of your room.

WIRELESS REMOTE CONTROL UNIT

The Wireless Remote Control Unit allows convenient control of air conditioner operation.

WIRED REMOTE CONTROL UNIT (OPTION)

SUPER QUIET OPERATION

When the FAN CONTROL button is used to select QUIET, the unit begins super-quiet operation; the indoor unit’s airflow is reduced to produce quieter operation.

AIR CLEANING MODE

Relies on the air conditioner’s power to quickly purify the air in the room.

ELECTRONIC AIR CLEAN FILTER

Install for use inside of the dust collection unit. For details on how to install the filter, please refer to page 15. Electrical power is used to charge the filter to remove contaminants from the air and to effectively collect dust and remove odors. It also helps to reduce the bacterial activity.

The optional wired remote control unit (model No.: AR-3TA ) can be used.

When you use remote control unit, there are following different points as compared with using wireless remote control unit.

[The additional functions for wired ones]

Weekly timer

Temperature set back timer

[The restricted functions for wired ones]

Air-cleaning function can't be turned ON/OFF. (During operation, it is always ON)

QUIET can't be selected in FAN MODE.

Sleep-timer can't be used.

And you can't use both wired remote control unit and wireless simultaneously. (Only one kind can be selected)

En-3

PREPARATION

Turn on the Power

In the case of a direct line connection, turn on the circuit breaker.

Load Batteries (R03 / LR03 × 2)

1

Press and slide the battery compartment lid on the re-

verse side to open it.

 

 

Slide in the direction of the arrow while pressing the mark.

2

Insert batteries.

 

Be sure to align the battery polarities (

) correctly.

3

Close the battery compartment lid.

Set the Current time

 

1

Press the TIME ADJUST button (Fig. 6 R).

Use the tip of a ball-point pen or other small object to press the button.

2

Use the , / - SET TEMP. / SET TIME buttons (Fig. 6

I) to adjust the clock to the current time.

 

, button: Press to advance the time.

 

 

- button: Press to reverse the time.

 

 

(Each time the buttons are pressed, the time will be advanced/reversed in

 

one-minute increments; hold the buttons depressed to change the time

 

quickly in ten-minute increments.)

 

3

Press the TIME ADJUST button again.

This completes the time setting and starts the clock.

CAUTION!

Take care to prevent infants from accidentally swallowing batteries.

When not using the remote control unit for an extended period, remove the batteries to avoid possible leakage and damage to the unit.

If leaking battery fluid comes in contact with your skin, eyes, or mouth, immediately wash with copious amounts of water, and consult your physician.

Dead batteries should be removed immediately and disposed of properly, either in a battery collection receptacle or to the appropriate authority.

Do not attempt to recharge dry batteries.

Never mix new and used batteries, or batteries of different types.

Batteries should last about one year under normal use. If the remote control unit’s operating range becomes appreciably reduced, replace the batteries and press the ACL button with the tip of a ballpoint pen or other small object.

To Use the Remote Control Unit

The Remote Control Unit must be pointed at signal receiver (Fig. 1 4) to operate correctly.

Operating Range: About 7 meters.

When a signal is properly received by the air conditioner, a beeping sound will be heard.

If no beep is heard, press the Remote Control Unit button again.

Remote Control Unit Holder

Insert

Slide up

Press in

Pull out

Screws

 

1 Mount the Holder. 2 Set the Remote Control

 

Unit.

3 To remove the Remote

 

 

Control Unit (when use at

 

hand).

En-4

OPERATION

To Select Mode Operation

1

2

Press the START / STOP button (Fig.6 M).

The indoor unit’s OPERATION indicator lamp (red) (Fig. 3 5) will light.

The air conditioner will start operating.

Press the MASTER CONTROL button (Fig.6 H) to select the desired mode.

Each time the button is pressed, the mode will change in the following

order.

 

sAUTO

sCOOL s DRY

HEAT t

FANt

About three seconds later, the entire display will reappear.

Example: When set to COOL.

 

To Set the Thermostat

Press the SET TEMP. / SET TIME buttons (Fig. 6 I).

, button: Press to raise the thermostat setting. - button: Press to lower the thermostat setting.

Thermostat setting range:

AUTO ..................................

64 to 88 °F

Heating ...............................

60 to 88 °F

Cooling/Dry ........................

64 to 88 °F

The thermostat cannot be used to set room temperature during the

FAN mode (the temperature will not appear on the remote control unit’s display).

About three seconds later, the entire display will reappear.

Example: When set to 86 °F.

The thermostat setting should be considered a standard value, and may differ somewhat from the actual room temperature.

To Set the Fan Speed

Press the FAN CONTROL button (Fig. 6 L).

Each time the button is pressed, the fan speed changes in the following order:

sAUTO sHIGH s MED

sLOW

sQUIET

About three seconds later, the entire display will reappear.

When set to AUTO:

Heating

: Fan operates so as to optimally circulate warmed air.

 

However, the fan will operate at very low speed when the tempera-

 

ture of the air issued from the indoor unit is low.

Cooling

: As the room temperature approaches that of the thermostat setting,

 

the fan speed becomes slower.

 

 

 

 

 

 

 

 

Fan

: The fan runs at the low fan speed.

 

 

 

 

Example: When set to AUTO.

 

The fan will operate at a very low setting during Monitor operation

 

and at the start of the Heating mode.

When set to QUIET:

SUPER QUIET operation begins. The indoor unit’s airflow will be reduced for quieter operation.

SUPER QUIET operation cannot be used during Dry mode. (The same is true when dry mode is selected during AUTO mode operation.)

Heating and Cooling performance will be reduced somewhat during SUPER QUIET operation.

To Stop Operation

Press the START/STOP button (Fig.6 M).

The OPERATION indicator lamp (red) (Fig. 3 5) will go out.

En-5

OPERATION

About AUTO CHANGEOVER Operation

AUTO: ● When AUTO CHANGEOVER operation first selected, the fan will operate at very low speed for about one minute, during which time the unit detects the room conditions and selects the proper operating mode.

If the differance between thermostat setting and actual room temperature is more than +4 °F → Cooling

If the difference between thermostat setting and actual room temperature is within ±4 °F → Monitor operation

If the difference between thermostat setting and actual room temperature is more than –4 °F → Heating operation

When the air conditioner has adjusted your room’s temperature to near the thermostat setting, it will begin monitor operation. In the monitor operation mode, the fan will operate at low speed. If the room temperature subsequently changes, the air conditioner will once again select the appropriate operation (Heating, Cooling) to adjust the temperature to the value set in the thermostat.

(The monitor operation range is ±4 °F relative to the thermostat setting.)

If the mode automatically selected by the unit is not what you wish, select one of the mode operation (HEAT, COOL, DRY, FAN).

About Mode Operation

Heating: ● Use to warm your room.

When Heating mode is selected, the air conditioner will operate at very low fan speed for about 3 to 5 minutes, after which it will switch to the selected fan setting. This period of time is provided to allow the indoor unit to warm up before begin full operation.

When the room temperature is very low, frost may form on the outside unit, and its performance may be reduced. In order to remove such frost, the unit will automatically enter the defrost cycle from time to time. During Automatic Defrosting operation, the OPERATION indicator lamp (red) will flash, and the heat operation will be interrupted.

Cooling: ● Use to cool your room.

Dry: ● Use for gently cooling while dehumidifying your room.

You cannot heat the room during Dry mode.

During Dry mode, the unit will operate at low speed; in order to adjust room humidity, the indoor unit’s fan may stop from time to time. Also, the fan may operate at very low speed when adjusting room humidity.

The fan speed cannot be changed manually when Dry mode has been selected.

Fan: ● Use to circulate the air throughout your room.

During Heating mode:

Set the thermostat to a temperature setting that is higher than the current room temperature. The Heating mode will not operate if the thermostat is set lower than the actual room temperature.

During Cooling/Dry mode:

Set the thermostat to a temperature setting that is lower than the current room temperature. The Cooling and Dry modes will not operate if the thermostat is set higher than the actual room temperature (in Cooling mode, the fan alone will operate).

During Fan mode:

You can not use the unit to heat and cool your room.

En-6