Fujitsu ASTG18KMCA, ASTG24KMCA User Manual

0 (0)
En-1PART No. 9320455002
AIR CONDITIONER
Wall Mounted Type
ASTG18KMCA
ASTG22KMCA
ASTG24KMCA
OPERATING MANUAL
Before using this product, read these instructions thoroughly and keep this manual for future reference.
To prevent personal injury, injury to others, or property damage, read this section carefully before you use this product, and be sure to comply to the
following safety precautions.
Incorrect operation due to failure to follow the instructions may cause harm or damage, the seriousness of which is classi ed as follows:
WARNING CAUTION
This mark warns of death or serious injury. This mark warns of injury or damage to property.
This mark denotes an action that is PROHIBITED.
This mark denotes an action that is COMPULSORY.
• Explanation of symbols displayed on the indoor unit or outdoor unit.
WARNING
This symbol shows that this appliance uses a ammable refrigerant. If the refrigerant is leaked and exposure to an external
ignition source, there is a risk of re.
CAUTION
This symbol shows that the Operation Manual should be read carefully.
CAUTION
This symbol shows that a service personnel should be handling this equipment with reference to the Installation Manual.
CAUTION
This symbol shows that information is available such as the Operating Manual or Installation Manual.
WARNING
• The appliance shall be installed, operated and stored in a
room with a oor area larger than 2.06m
2
.
• The appliance contains no user-serviceable parts. Always
consult authorized service personnel for repairing, installation,
and relocation of this product.
Improper installation or handling will cause leakage, electric
shock, or re.
• In the event of a malfunction such as burning smell,
immediately stop operation of the air conditioner, and
disconnect all the power supply by turning off the electrical
breaker or disconnecting the power plug. Then consult
authorized service personnel.
• Take care not to damage the power supply cable.
If it is damaged, it should only be replaced by authorized
service personnel.
• In the event of refrigerant leakage, be sure to keep away
from re or any ammables, and consult authorized service
personnel.
• If you see lightning or hear thunder, there might be a lightning
strike.
To prevent electric shock hazard, turn off the air conditioner
by using the remote controller, and do not touch the unit or
the power plug during thunderstorm.
• The appliance shall be stored in a room without continuously
operating ignition sources (for example: open ames, an
operating gas appliance or an operating electric heater).
• The appliance shall be stored in a well-ventilated area.
• Be aware that refrigerants may not contain an odour.
• The appliance shall be stored so as to prevent mechanical
damage from occurring.
• Disposing of the product shall be done properly, in
compliance with national or regional regulations.
• During transportation or relocation of the indoor unit, pipes
shall be covered with the wall hook bracket for protection.
Do not move the appliance by holding the indoor unit pipes.
(The stress applied to the pipe joints may cause the
ammable gas to leak during operation).
• This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless they
have been given supervision or instruction concerning use of
the appliance by a person responsible for their safety.
• Children should be supervised to ensure that they do not play
with the appliance.
(continued)
Contents
Safety Precautions ..........................................................En-1
Indoor Unit Overview and Operations .............................En-3
Remote Controller Overview and Operations ..................En-4
Timer Operation...............................................................En-6
Human Sensor (Energy Saving) ......................................En-8
Demand Response and Indoor Unit Operation ...............En-8
General Informations on Operation .................................En-9
Care and Cleaning.........................................................En-10
Troubleshooting ............................................................. En-12
R32
REFRIGERANT
This Air Conditioner contains and
operates with refrigerant R32.
THIS PRODUCT MUST ONLY BE INSTALLED OR SERVICED
BY QUALIFIED PERSONNEL.
Refer to Commonwealth, State, Territory and local legislation,
regulations, codes, installation & operation manuals, before
the installation, maintenance or service of this product.
9320455002_OM_EN.indd 19320455002_OM_EN.indd 1 7/23/2013 10:34:29 AM7/23/2013 10:34:29 AM
En-2
OPERATING MANUAL
WARNING
• Do not install the unit in area lled with mineral oil such as a
factory or area containing a large amount of splashed oil or
steam such as a kitchen.
• Do not start or stop the operation of this product by inserting
or pulling out the power plug, or by turning on or off the
circuit breaker.
• Do not use in ammable gases near the unit.
• Do not expose yourself directly to the cooling air ow for
many hours.
• Do not insert your ngers or any other objects into outlet
port, open panel, or intake grille.
• Do not operate with wet hands.
• Do not use means to accelerate the defrosting process or to
clean the appliance, other than those recommended by the
manufacturer.
• Do not pierce or burn.
CAUTION
• Provide occasional ventilation during use.
• Always operate the unit with air lters installed.
• Ensure that any electronic equipment is at least 1 meter
away from either the indoor unit or outdoor unit.
• Unplug the power supply cable when not using the indoor
unit for an extended period.
• After long period of use, check whether the installation stand
does not deteriorate to prevent the unit from falling down.
• The air ow direction and the room temperature should be
carefully considered when you use this product in a room
with infants, children, elderly or sick persons.
• Do not place vase or water container on the unit.
• Do not place any other electrical products or household
belongings under indoor unit or outdoor unit.
Dripping condensation from the unit might get them wet, and
may cause damage or malfunction of your property.
• Do not expose the unit directly to water.
• Do not use this product for preservation of food, plants,
animals, precision equipment, art work, or other objects. This
may cause quality deterioration of those items.
• Do not expose animals or plants to the direct air ow.
• Do not drink the drainage from the air conditioner.
• Do not pull the power supply cable to disconnect the plug.
• Do not touch the aluminum ns of heat exchanger built-in
the indoor or outdoor unit to avoid personal injury when you
install or maintain the unit.
• Do not direct the air ow at replaces or heating apparatus.
• Do not block or cover the intake grille and the outlet port.
• Do not apply any heavy pressure to radiator ns.
Do not climb on, place objects on, or hang objects from the unit
.
Safety Precautions (continued)
Indoor unit accessories
Remote
controller
Batteries Air cleaning lters Filter holders
Remote controller
holder
Tapping screws
(M3 × 12 mm)
Remote controller holder installation
321
Screws
Insert
Slide up
WARNING
Take care to prevent infants and young children from acciden-
tally swallowing the batteries.
CAUTION
• Do not attempt to recharge dry batteries.
• Do not use dry batteries that has been recharged.
Battery (R03/LR03/AAA × 2) loading and remote controller preparation
1
4
2
3
6
7
8
5
9
5
Press CLOCK ADJUST button to start clock setting.
6
Set the day of the week by pressing SELECT button (Monday to
Sunday). *By pressing the TEMP. (
∧∨
) buttons, the time indicator
can be changed from a 24-hour to a 12-hour clock.
7
Press NEXT button to continue.
8
Set the time by pressing SELECT button.
Pressing
or
changes the value by the minute.
Pressing down on
or
changes the value by 10 minutes.
9
To complete, press the SEND button close to the indoor unit.
Settings may not be properly sent if pressed from a distance.
Notes:
Use speci ed type of batteries only.
Do not mix different types or new and used batteries together.
• Batteries can be used about 1 year in ordinary use.
If the remote control range noticeably shortens, replace the batter-
ies, and press RESET button as shown in page 5.
9320455002_OM_EN.indd 29320455002_OM_EN.indd 2 7/23/2013 10:34:38 AM7/23/2013 10:34:38 AM
En-3
AIR CONDITIONER Wall Mounted Type
OPERATING MANUAL
1 Intake grille
Before starting operation, make sure that the intake grille has been
shut completely. Incomplete closing may have an effect on the proper
function or performance of the product.
2 MANUAL AUTO button
Use when the remote controller is lost or there is a malfunction.
Status Action Mode or operation
In operation Press more than 3 seconds. Stop
Stopping Press more than 3 seconds and
less than 10 seconds.
AUTO
Press more than 10 seconds.
(Only for servicing.*)
Forced cooling
After cleaning Press less than 3 seconds. Filter indicator reset
*:To stop forced cooling, press this button or START/STOP button on
the remote controller.
3 Front panel
See page 8
4 Human Sensor
Used for Energy Saving Program. Controls temperature setting by
detecting people in the room.
5 Vertical air ow direction louver
Each time you press Vertical SET button on the remote controller, the
angle of the vertical air ow direction louver moves as follows:
1
2
3
4
5
6
7
8
COOL or DRY mode HEAT mode
12
3
765
*
4
8
*
*: Default setting in each mode.
• Do not adjust by hand.
• At the beginning of AUTO or HEAT mode, they may stay on position
1 for a while for adjustment.
• If the angle is set to position 5-8 for more than 30 minutes in COOL
or DRY mode, the louver will automatically return to position 4.
Keeping the position 5-8 during COOL or DRY mode may cause
condensation to form, and the drops may damage your property.
6 Power diffuser
In conjunction with movement of the vertical air ow direction louver,
the angle of the power diffuser moves as follows:
Vertical air ow
direction louver
Power diffuser
3
76
5
4
2
1
8
• In SWING operation, power diffuser does not move.
7 Horizontal air ow direction louver
Each time you press the Horizontal SET button on the remote controller,
the air ow direction range of the horizontal air ow direction louver will
change as follows:
1
2
3
4
5
Horizontal air ow direction louver
54
1
3
*
2
*: Default setting.
8 Drain hose
9 Remote controller signal receiver
CAUTION
For appropriate signal transmission between remote controller and
indoor unit, keep the signal receiver away from the following items
:
- Direct sunlight or other strong lights
- Flat-panel television screen
In rooms with instantaneous uorescent lights, such as in-
verter type ones, the signal may not be transmitted properly. In
such a case, consult the store of purchase.
1
14
13
11
12
8
3
4
2
7
5
6
10
9
10
ECONOMY indicator (green)
Lights in ECONOMY operation and in 10 °C HEAT operation.
11
TIMER indicator (orange)
Lights in TIMER operation, and blinks slowly when the timer setting
error is detected.
For details, refer to “Auto-restart function” on page 9.
12 OPERATION indicator (green)
Lights in normal operation, and blinks slowly in Automatic defrosting
operation.
Blinks during Demand Response operation. For details, refer to page
8.
See page 10
13
Air lter
See page 11
14
Air cleaning lters
Purify or deodorize the air, and provide fresh air ow.
Indoor Unit Overview and Operations
9320455002_OM_EN.indd 39320455002_OM_EN.indd 3 7/23/2013 10:34:40 AM7/23/2013 10:34:40 AM
En-4
OPERATING MANUAL
CAUTION
• To prevent malfunction or damage of the remote controller:
- Place remote controller at where will not be exposed to
direct sunlight or excessive heat.
- Remove batteries if the product is not going to be used for
an extended period.
- Exhausted batteries must be removed immediately, and
be disposed according to the local laws and regulations of
your region.
• If leaking battery uid comes in contact with your skin, eyes,
or mouth, immediately rinse with plenty of clean water, and
consult your physician.
• Obstacles such as a curtain or wall between the remote
controller and the indoor unit may affect the appropriate
signal transmission.
• Do not apply strong shocks to the remote controller.
• Do not pour water on the remote controller.
Remote Controller Overview and Operations
22
19
20
18
23
2
21
3
1
5
6
7
17
24
4
11
16
15
8
9
10
14
13
12
You can quickly start operation with the following 3 steps:
1 START/STOP button
2 MODE button
Switches operation mode in following order.
AUTO COOL DRY FAN HEAT
Notes in HEAT mode:
• At the beginning of the operation, the indoor unit operates at very
low fan speed for about 3–5 minutes for preparation, then switches
to the selected fan speed.
• Automatic defrosting operation overrides the heating operation when
necessary.
3 TEMP. (temperature) buttons
Sets the desired temperature.
In COOL or DRY mode, the temperature needs to be set lower than
the current room temperature. In HEAT mode, the temperature needs
to be set higher than the current room temperature.
Otherwise, corresponding operation mode may not start.
Temperature setting range
AUTO/COOL/DRY 18–30 °C
HEAT 16–30 °C
Notes: Temperature control is not available in FAN mode.
4 Remote controller display
In this section, all the possible indicators are displayed for description.
In actual operation, the display is linked with the button operation, and
only shows the necessary indicators for each setting.
5 POWERFUL button
Activates the POWERFUL operation.
The unit will operate at maximum power and strong air ow to quickly
cool down or warm up the room.
When activated, the indoor unit will emit 3 short beeps.
To turn off, press the POWERFUL button again. The indoor unit will
then emit 2 short beeps.
POWERFUL operation is automatically turned off in the following
situations:
• Adjusted room temperature reaches the set temperature in COOL,
DRY, or HEAT mode.
• 20 minutes have passed after the POWERFUL operation mode has
been set.
Even in situations above, the POWERFUL operation will not
automatically turn off unless it has run for a certain amount of time.
Notes:
• The air ow direction and the fan speed are controlled automatically.
• This operation cannot be performed simultaneously with ECONOMY
operation.
• POWERFUL operation will override the OUTDOOR UNIT LOW
NOISE, ENERGY SAVING functions. Both functions, if set, will start
after the POWERFUL operation is turned off.
6 10 °C HEAT button
Starts 10 °C HEAT operation that mainains the room temperature at
10 °C so as to prevent the room temperature to drop too low.
After pressing the button to start the 10 °C HEAT operation, the
indoor unit emits 2 short beeps and the ECONOMY indicator (green)
will turn on.
To turn off, press the START/STOP button. The Economy indicator
will turn off.
Notes:
• In 10 °C HEAT operation mode, only the vertical air ow direction
can be adjusted by using the SET button.
• HEAT mode will not be performed if the room temperature is warm
enough.
(continued)
9320455002_OM_EN.indd 49320455002_OM_EN.indd 4 7/23/2013 10:34:41 AM7/23/2013 10:34:41 AM
Loading...
+ 8 hidden pages