7 How to Order Parts 34
8 EC Declaration of Conformity 35
flowserve.com
3
1
Limitorque Actuation Systems L120 Series FCD LMENIM1201-04-AQ – 05/15
Introduction
1.1 Purpose
This Installation and Maintenance Manual explains how to install and maintain the L120-10, L120-20,
and L120-40 actuators. Information on installation, disassembly, reassembly, lubrication, and parts is
provided.
1.2 User Safety
Safety notices in this manual detail precautions the user must take to reduce the risk of personal injury
and damage to the equipment. The user must read and be familiar with these instructions before
attempting installation, operation, or maintenance. Work to be performed on the actuator should be
carried out by a qualified tradesman familiar with the operation and maintenance of electric actuators.
Failure to observe these precautions could result in serious bodily injury or death, damage to the equipment, voiding of the warranty, or operational difficulty.
Safety notices are presented in this manual in three forms:
c WARNING: Refers to personal safety. Alerts the user to potential danger. Failure to follow warning
notices could result in personal injury or death.
a CAUTION: Directs the user’s attention to general precautions that, if not followed, could result in
personal injury and/or equipment damage.
NOTE: Highlights information critical to the user’s understanding of the actuator’s installation and
operation.
4
2
Limitorque Actuation Systems L120 Series FCD LMENIM1201-04-AQ – 05/15
Product Capabilities and Features
L120 Series actuators operate without modification in any rising or non-rising stem application for
linear action valves.
The actuators meet rigid safety requirements. The actuators are available in weatherproof, explosionproof, and submersible configurations.
The actuators are compatible with a wide range of control options from stand-alone units with local
pushbutton to open standards-based DDC-100 networks with up to 250 actuators.
The actuators are designed with integral control packages including plug-in interconnect boards that
increase control functionality for stand-alone or networked units.
Durable torque overload is provided in both directions of travel.
2.1 Initial Inspection and Storage Instructions
c WARNING: Read this Installation and Maintenance Manual carefully and completely before
attempting to store the actuator. Be aware of the electrical hazards.
2.1.1 Inspection and Recording
Upon receipt of the actuator, inspect the condition of the equipment and record nameplate
information:
1. Carefully remove actuator from shipping carton or skid. Thoroughly examine the
equipment for any physical damage that may have occurred during shipment. If
damaged, immediately report the damage to the transport company.
2. Record the actuator nameplate information for future reference; i.e. ordering parts,
obtaining further information.
5
flowserve.com
Limitorque Actuation Systems L120 Series FCD LMENIM1201-04-AQ – 05/15
Handwheel
2.1.2 Short Term Storage Procedures (less than 1 year)
NOTE: The following are our recommended storage procedures to retain maximum product integrity
during short-term storage. Failure to comply with recommended procedures will void the warranty. For
longer-term storage, contact Limitorque for procedures and recommendations.
Actuators are not weatherproof until properly installed on the valve or prepared for storage.
Store actuators in a clean, dry, protected warehouse away from excessive vibration and rapid temperature changes. If the actuators must be stored outside, they must be stored off the ground, high enough
to prevent them from being immersed in water or buried by snow.
1. Position the actuator in storage with motor and switch compartment horizontal.
2. Connect the internal heaters (if supplied) or place desiccant in the switch compartment.
3. Replace all plastic caps or plugs with pipe plugs and ensure that all covers are tight.
4. If the actuator is mounted on a valve and the stem protrudes from the unit, a suitable stem cover
must be provided.
Limit Switch/
Controls
Compartment
Figure 2.1 – L120-10 through 40
Motor
Housing
Actuator
Nameplate
(hidden)
Declutch
Lever
6
Limitorque Actuation Systems L120 Series FCD LMENIM1201-04-AQ – 05/15
2.2 Product Identification
The actuator unit nameplate is located on the back of the unit, opposite the limit switch compartment.
The nameplate contains the following information:
• Limitorque name
• Point of Manufacture
• Unit Size
• Order Number
• Serial Number
• Customer Tagging
• CE Stamp
The motor nameplate is located on the motor. The nameplate contains the following information:
• ID Number
• Start Torque
• Run Torque
• Enclosure Type
• RPM
• Volts
• Full Load Amps
• Locked Rotor Amps
• Insulation Class
• Duty
• Horsepower
• Service Factor
• Phase
• Cycles
• Motor Code
• Ambient Temperature
• Connection Diagram
flowserve.com
7
3
Limitorque Actuation Systems L120 Series FCD LMENIM1201-04-AQ – 05/15
Actuator Weights
The approximate L120 actuator weights are provided below:
Table 3.1 – Actuator weights
Actuator
Size
L120-10
L120-20
L120-40
Control Types
NCU10045112511074911954
BIC11552127581225513461
CLAMSHELL14064152691476715972
NCU14064158721536917178
BIC15570173781687618684
CLAMSHELL18082198901938821196
NCU190862169821296238108
BIC20593231105227103253115
CLAMSHELL230105256116252114278126
Drive 1 Weight (lb./kg)Drive 2 Weight (lb./kg)
Top HWSide HWTop HWSide HW
lb.kglb.kglb.kglb.kg
8
4
Limitorque Actuation Systems L120 Series FCD LMENIM1201-04-AQ – 05/15
Installation Instructions
4.1 Safety Precautions
c WARNING: Read this Installation and Maintenance Manual carefully and completely before
attempting to install, operate, or troubleshoot the Limitorque L120 actuator.
c WARNING: Be aware of electrical hazards. Turn off incoming power before working on the actuator
and before opening the switch compartment.
c WARNING: Potential HIGH-PRESSURE vessel – Be aware of high-pressure hazards associated with
the attached valve or other actuated device when installing or performing maintenance on your
L120 actuator. Do not remove the actuator mounting bolts when the actuator is mounted on a rising
stem valve unless the valve is in the FULLY OPEN position and there is NO pressure in the line.
c WARNING: Do not manually operate the actuator with devices other than installed Handwheel and
Declutch Lever. Using force beyond the ratings of the unit and/or using additive force devices such
as cheater bars, wheel wrenches, pipe wrenches, or other devices on the actuator Handwheel or
Declutch Lever may cause serious personal injury and/or damage to the actuator or valve.
c WARNING: Do not work on the actuator while it is mounted on a torque-seated valve.
4.2 Safety Practices
The following checks should be performed to maintain safe operation of the L120 actuator.
• Mount motors on a horizontal plane, if possible.
• Keep the switch compartment clean and dry.
• Keep the valve stem clean and lubricated.
• Set up periodic operating schedule for infrequently used valves.
9
flowserve.com
Limitorque Actuation Systems L120 Series FCD LMENIM1201-04-AQ – 05/15
• Carefully check for correct motor rotation direction. If the motor is driving the valve in the wrong
direction, interchange any two leads on three-phase motors or switch the armature leads on DC and
single-phase motors.
• Use a protective stem cover. Check valve stem travel and clearance before mounting covers on rising
stem valves.
• Verify all actuator wiring is in accordance with the applicable wiring diagram, national and local codes,
and Table 4.1.
Table 4.1 – Required Rating for External Wiring
Up to:Use wire rated at least:
40°C60°C
60°C75°C
4.3 Initial Actuator Preparation
Replace all molded plastic conduit and top protectors (installed for shipping purposes only) with pipe
plugs when installation wiring is complete.
4.3.1 Mounting Base
The mounting hole sizes and quantities are as detailed in Table 4.2.
Table 4.2 – Mounting Base Dimensions
Actuator Size
L120-104
L120-204
L120-404
Mounting HolesTap size
QuantityMSSISO
3
⁄8-16x0.88M10x1.5x22.4
5
⁄8-11x1.25M16x2x32
5
⁄8-11x1.25M16x2x32
4.3.2 Stem Acceptance
The maximum stem acceptance is provided in Table 4.3.
Table 4.3 – Maximum Stem Acceptance
Drive 2Drive 1
Actuator size
L120-101.25321.0025¼x3/328x6
L120-202.25571.87547½x3/1614x9
L120-402.625662.12552½x3/1616x10
TappedBoreKey
inchmminchmminchmm
10
Limitorque Actuation Systems L120 Series FCD LMENIM1201-04-AQ – 05/15
Balancing
600 Volt Torque Switch
Microswitch-Style Torque Switch
4.4 Torque Switch
The torque switch is designed to protect the actuator in open and close directions.
a CAUTION: Disconnect all incoming power before opening limit switch compartment or working on
the torque switch.
• Do not use abrasive cloth to clean the contacts on the torque switch.
• Do not torque seat 90° operation valves nor run them against the stops. This may cause damage
to the valve.
NOTE: If the actuator has “torqued out,” release torque buildup by operating the actuator manually.
4.4.1 Setting Torque Switch
The torque switch was set at the factory according to customer-supplied information regarding necessary torque or thrust output that was provided at the time of the order. However, if the setting needs to
be adjusted, perform the following procedure:
a CAUTION: A torque switch limiter plate is provided on most actuators.
• Removal or modification of the torque switch limiter plate will void the actuator warranty.
• Do not exceed the setting indicated by this plate without contacting the Limitorque service
department.
• Installing or adjusting the torque switch with the actuator in a loaded condition will result in a loss
of torque protection.
Item letters correspond to Figure 4.1.
1. Place the L120 actuator in manual mode.
2. Release the load on the wormshaft spring pack.
3. For open and close directions, loosen Screw (A) and move Pointer (B) to desired position. A higher
number indicates a high torque and/or thrust output.
4. Tighten Screw (A).
5. Operate the valve electrically to seat valve and to ensure tight shutoff.
6. Rebalance torque switch if required.
Figure 4.1 – Microswitch-Style Torque Switch and 600 Volt Torque Switch
B
Maximum Stop
Setting Plate
Index Marks
A
Maximum Stop
Setting Plate
OPEN
-10-20
-10-20
CLOSE
Mounting
B
Screw
A
Balancing
Screws
Index Marks
B
A
A
B
Mounting
Screw
Screws
11
flowserve.com