Installation Manual
®
Omnicell
Model: 9106 FB
© 2007 by Fairbanks Scales, Inc. Revision 2 10/07
All rights reserved
51176
Amendment Record
Omnicell 9106 FB
DOCUMENT 51176
Manufactured by Fairbanks Scales Inc.
821 Locust Street
Kansas City, Missouri 64106
Created 08/2007
Revision 0 08/2007 Preliminary Release
Revision 1 09/2007 Documentation Release
Revision 2 10/2007 Specifications Update
10/07 3 51176 Rev. 2
Disclaimer
Every effort has been made to provide complete and accurate information in this manual. However,
although this manual may include a specifically identified warranty notice for the product, Fairbanks
Scales makes no representations or warranties with respect to the contents of this manual, and
reserves the right to make changes to this manual without notice when and as improvements are
made.
It is the responsibility of the requesting party to develop, maintain, install, and connect networking
devices and general network connectivity as it applies to the originating party’s network. No warranty
or guarantee, expressed or implied, concerning the network, its design, its installation, or operational
characteristics has been offered by Fairbanks Scales. Fairbanks Scales shall not be liable for any
loss, damage, cost of repairs, incidental or consequential damages of any kind, whether or not based
on express or implied warranty, contract, negligence, or strict liability arising in connection with the
design, development, installation, or use of an intended network.
© Copyright 2007
This document contains proprietary information protected by copyright. All rights are reserved; no part
of this manual may be reproduced, copied, translated or transmitted in any form or by any means
without prior written permission of the manufacturer.
10/07 4 51176 Rev. 2
Table of Contents
SECTION 1: GENERAL INFORMATION ..................................................................6
Description........................................................................................................................... 6
Features .............................................................................................................................. 6
Applications ......................................................................................................................... 6
Dimensions (In Inches)................................................................................................................... 7
Wiring .........................................................................................................................................`7
Specifications ...................................................................................................................... 8
SECTION 2: INSTALLATION.....................................................................................9
General Service Policies ..................................................................................................... 9
Phases of Installation...................................................................................................................... 9
Conferring with Our Client............................................................................................................... 9
Pre-Installation Checklist ..............................................................................................................10
Unpacking..................................................................................................................................... 10
User’s Responsibilities.................................................................................................................. 11
Installation ......................................................................................................................... 12
Basic Assembly Steps .................................................................................................................. 12
Omnicell® Placement.................................................................................................................... 13
SECTION 3: PARTS.................................................................................................14
Omnicell® 9106 FB Complete Units.............................................................................................. 14
Load Cells..................................................................................................................................... 14
Parts Not Supplied........................................................................................................................ 15
Omnicell 9106 FB Parts................................................................................................................ 16
10/07 5 51176 Rev. 2
Section 1: General Information
DESCRIPTION
Fairbanks’ Omnicell® 9106 FB Series is a single-ended beam weighing assembly.
It is a cost-effective choice for medium-to-high capacity, non-commercial weighing
applications requiring protection from extreme hostile and washdown environments.
FEATURES
• Medium-to-High Weight Ranges.
• Designed for non-commercial applications.
• 1,000 to 10,000 lb capacity models.
• Integral height adjustment on the receiver plate for easy load balancing.
• Articulating mounting plate which accommodates non-planar misalignments of
up to four degrees (4°).
• Load Cells constructed from 17-4 PH Stainless Steel Load Cells.
• Mount constructed with 304 Stainless Steel.
• Low profile design with integral height adjustment.
• Factory Mutual approved for hazardous applications.
APPLICATIONS
• High Accuracy • Tanks • Bins
• Process Reactors • Mixing • Blending
• Hostile Environments • Hoppers • Batching
10/07 6 51176 Rev. 2