Fairbanks H90-3052-D User Manual

0 (0)

OPERATING MANUAL

Factory Mutual approved Weighing Systems for hazardous (explosive) area application. Repair is expressly limited to factory trained service personnel.

Fairbanks Scales

HAZARDOUS ENVIRONMENT INDICATOR

Model H90-3052-D

50144

Revision 3

PRINTED IN U.S.A.

1/12

50144 Rev. 4

TABLE OF CONTENTS

SECTION 1: DESCRIPTION………………………………………………………...4

1.1.Introduction…………………………………………………………………………………. 4

1.2.Specifications.……………………………………………………………………………….4

SECTION 2: FRONT PANEL………………………………………………………..5

2.1.Keys…………………………………………………………………………………………. 5

2.2.Indicators…………………………………………………………………………………….5

2.3.Displayed Legends………………………………………………………………………… 6

2.4.Blank Display……………………………………………………………………………….. 6

2.5.Low Battery Condition……………………………………………………………………... 6

2.6.Low Battery Legends……………………………………………………………………….6

2.7.Black Panel Description…………………………………………………………………… 6

SECTION 3: OPERATION………………………………………………………….. 7

3.1.Instrument Weighing Functions………………………………………………………….. 7

3.2.General Weighing Operations……………………………………………………………. 7

SECTION 4: BATTERY CHARGER………………………………………………. 8

4.1.Descriptions………………………………………………………………………………... 8

4.2.Specifications………………………………………………………………………………. 9

4.3.States of Operation…………………………………………………………………………9

4.4.LED State Reference Chart………………………………………………………………..10

4.5.Theory of Operations.……………………………………………………………………... 11

SECTION 5: INSTRUMENT SEALING…………………………………………… 12 SECTION 6: CONTROL DRAWINGS……………………………………………... 13

DISCLAIMER

Every effort has been made to provide complete and accurate information in this manual. However, although this manual may include a specifically identified warranty notice for the product, Fairbanks Scales makes no representations or warranties with respect to the contents of this manual, and reserves the right to make changes to this manual without notice when and as improvements are made to the product.

50144 Rev. 4

Fairbanks H90-3052-D User Manual

FIGURE 1-1: MODEL H90-3052-D

SECTION 1:

DESCRIPTION

1.1 Introduction

The model H90-3052-D indicator is a general purpose indicator that can be united with a wide variety of Fairbanks platforms. Stainless steel construction makes the instrument well suited for use in wash-down locations.

The H90-3052-D is battery operated for unlimited portability. The battery packs are rechargeable.

1.2 Specifications

1.Model Number:

H90-3052-D

2.Units: lb, kg

3.Display:

High visibility, 6 digit liquid crystal display, with 0.8 inch digits

4.Display Update Rate:

Programmable for 0.2, 0.4, 0.8 or 1.2 seconds

4

5.Digital Filter:

Programmable - 4 levels

6.Auto-Zero Tracking:

Programmable OFF, 0.6d, 1.0d, or 3.0d

7.Re-zero Range:

Programmable 0 to 100%, or 0 to +2%

8.Filter Motion Band:

Programmable 0.5, 1.0, 2.0, 3.0d

9.Temperature Range:

Operating: – 10° to 40° C Storage: – 20° to 60° C

10.Controls:

18 key keypad

11. Battery Life:

Continuous operation, with one 350 ohm load cell, 55 hours

12. Capacity:

Min: 10 lb x .002 Max: 20,000 lb x 5

50144 Rev. 4

FIGURE 2-1: FRONT PANEL

SECTION 2:

FRONT PANEL

2.1 Keys

ON

Turns instrument ON, after battery pack replacement, when automatic shut-down mode turns instrument the OFF, or when the operator turns the instrument off.

OFF

Turns instrument OFF.

GROSS

NET

Toggles between GROSS and NET modes

AUTO

TARE

Enters the weight on the platform into TARE memory and sets the scale to the NET mode

UNITS

Toggles the indicators between lb and kg

5

ZERO

With the scale in GROSS mode, sets the display equal to ZERO and turns on the Center-Of- Zero indicator

TARE

RECALL

Causes display of current tare weight

TARE

ENTER

Enters tare weight as input by the operator through the numeric keypad

0 through 9

Numeric keys for manual input of tare weight

2.2 Indicators

NET

Net Mode

TARE

Tare Mode

lb pounds

kg kilograms

50144 Rev. 4